with safety MACX Analog

Signal conditioners with
Functional Safety
The MACX ranges
Bro IE MACX Analog DE.indd 1
03.03.14 15:45
Reliable and safe
MACX signal conditioners
Maximum safety for your systems and
machines: in all phases of the product
lifecycle, MACX signal conditioners have
been developed and produced according to
standards for Functional Safety.
Concept
Development
All safety-related
functions are defined and
assessed right from the
creation of the product
specification.
Product development
incorporates hazard and
risk analyses as well as
measures for ensuring
the required safety
integrity.
A solution for every type of signal
Maximum explosion protection
Analog signals with performance level
Safely isolate, adjust, filter, and amplify:
MACX Analog offers comprehensive
solutions for analog signal processing.
Highly compact and leading
technology: with a design width of
just 12.5 mm, MACX Analog Ex offers
single and two-channel signal isolators
for intrinsically safe circuits in the
hazardous area.
With MACX Safety, you can integrate
analog signals easily into your safety
application according to the Machinery
Directive, even for intrinsically safe circuits
in the hazardous area.
For more information, see page 6 onwards
For more information, see page 16 onwards
For more information, see page 10 onwards
Ex approvals according to ATEX, IECEx
2
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 2
• Ex i for intrinsically safe circuits up to
zone 0 and zone 20
• Ex n for installation in zone 2
03.03.14 15:45
Safety lifecycle
Phoenix Contact meets the requirements of Functional
Safety according to IEC 61508 in a standardized
development process. We take measures for fault avoidance
and fault control into consideration, from the very
development and production of a device right up to device
operation.
Production
Device operation
During production, all of
the defined specifications
and test instructions are
consistently implemented,
verified, and validated.
Certified safety offers
the highest standard of
quality and reliability
during device operation.
Tested quality and safety
Independent test centers are involved throughout the entire development cycle and
audit the measures as part of a full assessment. The certificates, technical information,
and the safety manual are available for you to download.
www.phoenixcontact.com
Funcional Safety
Type Approved
®
TÜV Rheinland
e ida
Temperature control and monitoring with safe shutdown
Temperature transducer
MACX MCR-T-UIREL-UP
Control
valve
Valve
Open/closed
Heat exchanger circuit
Temperature
sensor
Temperature transducer
MACX MCR-T-UI-UP
The temperature in the tank
is continuously controlled and
monitored. Here, closed-loop
control and the safety equipment
are consistently isolated. In the
event that the limit values are
exceeded, the process is switched
to the safe state via the additional
temperature transducer.
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 3
3
03.03.14 15:45
MACX signal conditioners
Your advantages
The MACX signal conditioner ranges
combine high mechanical and electronic
functionality in the same housing.
Benefit from the many advantages of this
consistent design.
HART communication
Bidirectional transmission of the
HART communication signal for
numerous analog IN/OUT product
types.
Flexible power supply
Versions with wide range input enable
worldwide use in power supply networks.
Universal
Power Input
T-Connector
Compatible
Easy power bridging, system
expansion or module
replacement during operation
with the modular DIN
rail connector for 24 V
versions.
Choice of connection technology
Wiring with screw connection or fast
and tool-free push-in technology
Convenient configuration
Set standard functions directly
on the front of the device via
DIP switches.
4
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 4
Easy-maintenance
connection terminal blocks
Plug-in, coded connection
terminal blocks with integrated
test sockets.
03.03.14 15:45
Product overview
Analog IN/
Analog OUT
Signal conditioners
• Universal and standard
3-way isolators
• 3-way repeater power supplies
(single and two-channel)
• 3-way output isolators
• 4-way signal duplicators
MACX
MACX
MACX
MACX
Precise, interference-free signal
transmission
Precise and interference-free signal
transmission, thanks to the patented
transmitter concept with safe electrical
isolation.
Temperature
TC/mV
R/POTI
-
-
+
+
Long service life and high operational
reliability over the entire operating
temperature range, thanks to low power
consumption and self-heating.
Page 17
Page 9
Page 14
Solenoid drivers
-
-
+
+
Extended configuration and monitoring can
be conveniently carried out via the PC with
the free ANALOG-CONF software or via
FDT/DTM.
Page 8
Page 13
• Single and two-channel
• Relay and transistor outputs
• Signal duplicators
MACX Analog
MACX Analog Ex
Digital OUT
Easy configuration and monitoring
Analog
Analog Ex
Safety
Safety Ex
NAMUR signal conditioners
Digital IN
+
Page 17
• Universal and standard
measuring transducers
• 3-way measuring transducers
• 4-way measuring transducers
with switching output
• Threshold value switches
MACX
MACX
MACX
MACX
Long service life and high operational
reliability
Page 7
Page 12
Temperature transducers
RTD
-
Analog
Analog Ex
Safety
Safety Ex
• Versions with various output
characteristic curves for all
solenoid valves on the market
• Loop-powered versions
• Versions with logic input
MACX Analog Ex
Page 15
Termination Carriers
Page 18
Accessories
Page 22
• Operator interface and display
unit
• Supply components
• Programming adapter
• HART multiplexer
and more
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 5
5
03.03.14 15:45
A solution for every type of signal
MACX Analog
Safely isolate, adjust, filter, and amplify:
MACX Analog offers comprehensive
solutions for analog signal processing. Save
planning and operating costs by combining
high signal flexibility with safe isolation and
SIL evaluation.
Universal temperature
transducers
• For RTD, TC, resistance-type
sensors, mV voltages, and customerspecific characteristic curves
• Universal power supply
• Freely adjustable PDT relays as
signal and alarm outputs
Operator interface
• On-site display of process values
• Easy monitoring, configuration, and
copying without software
• Can be snapped onto a measuring
transducer or DIN rail
Analog signal conditioner
• 1600 signal combinations
• Easily adjustable via DIP
switch
• Short response time
6
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 6
Easy-maintenance
connection terminal blocks
Plug-in, coded connection
terminal blocks with integrated
test sockets.
03.03.14 15:45
MACX Analog – product overview
Analog IN
Analog IN
Analog IN
SIL 2
IN
U,I
U,I
SIL 2
IN
OUT
POWER
U,I
U,I
SIL 2
POWER
OUT
IN
I
POWER
T-Connector
Compatible
OUT
POWER
T-Connector
Universal
Power Input
Universal 3-way signal conditioner,
configurable
I
Compatible
Repeater power supply and input signal
conditioner,
HART-compatible
Universal 3-way signal conditioner,
configurable
IN
Unipolar: 0 … 50 mV to 0 … 100 V,
0 … 1 mA to 0 … 10 mA
Bipolar: -50 … 50 mV to -100 … 100 V,
-1 … 1 mA to -100 … 100 mA
Live zero: 1 … 5 mA , 2 … 10 mA ,
4 … 20 mA , 1 … 5 V, 2…10 V
Configurable via DIP switch; for additional
signal combinations, see data sheet
Unipolar: 0 … 50 mV to 0 … 100 V,
0 … 1 mA to 0 … 10 mA
Bipolar: -50 … 50 mV to -100 … 100 V,
-1 … 1 mA to -100 … 100 mA
Live zero: 1 … 5 mA , 2 … 10 mA ,
4 … 20 mA , 1 … 5 V, 2…10 V
Configurable via DIP switch; for additional
signal combinations, see data sheet
Input isolator operation:
4 … 20 mA (0 … 20 mA)
Repeater power supply operation:
4 … 20 mA
Transmitter supply voltage:
> 16 V (20 mA)
OUT
Unipolar: 0 … 2.5 V, 0 … 5 V, 0 … 10 V,
0 … 5 mA , 0 … 10 mA, 0 … 20 mA
Bipolar: -2.5 … 2.5 V, -5 … 5 V, -10 … 10 V,
-5 … 5 mA, -10 … 10 mA,
-20 … 20 mA
Live zero: 1 … 5 mA , 2 … 10 mA, 4 … 20 mA,
0.5 … 2.5 V, 1 … 5 V, 2 … 10 V
Configurable via DIP switch; for additional
signal combinations, see data sheet
Unipolar: 0 … 2.5 V, 0 … 5 V, 0 … 10 V,
0 … 5 mA , 0 … 10 mA, 0 … 20 mA
Bipolar: -2.5 … 2.5 V, -5 … 5 V, -10 … 10 V,
-5 … 5 mA, -10 … 10 mA,
-20 … 20 mA
Live zero: 1 … 5 mA , 2 … 10 mA, 4 … 20 mA,
0.5 … 2.5 V, 1 … 5 V, 2 … 10 V
Configurable via DIP switch; for additional
signal combinations, see data sheet
Input isolator operation:
4 … 20 mA (0 … 20 mA) active/passive
Repeater power supply operation:
4 … 20 mA active/passive
12.5 mm
12.5 mm
12.5 mm
Screw
connection
MACX MCR-UI-UI-NC
2811446
MACX MCR-UI-UI-UP-NC
2811297
MACX MCR-SL-RPSSI-I
2865955
Push-in
connection
MACX MCR-UI-UI-SP-NC
2811556
MACX MCR-UI-UI-UP-SP-NC
2811569
MACX MCR-SL-RPSSI-I-SP
2924207
Analog IN
Analog OUT
Design width
Analog IN
SIL 2
SIL 2
POWER
IN
I
I
POWER
T-Connector
Compatible
Repeater power supply and input signal
conditioner with two outputs,
HART-compatible
SIL 2
OUT
OUT
I
I
IN
POWER
Universal
Power Input
Repeater power supply and input signal
conditioner,
HART-compatible
Output signal conditioner,
HART-compatible
IN
Input isolator operation:
4 … 20 mA (0…20 mA)
Repeater power supply operation:
4 … 20 mA
Transmitter supply voltage:
> 16 V (20 mA)
Input isolator operation:
4 … 20 mA (0…20 mA)
Repeater power supply operation:
4 … 20 mA
Transmitter supply voltage:
> 16 V (20 mA)
4 … 20 mA (0 … 20 mA)
With line fault detection
OUT
Input isolator operation:
4 … 20 mA (0 … 20 mA) per output, active
Repeater power supply operation:
4 … 20 mA per output, active
Input isolator operation:
4 … 20 mA (0 … 20 mA) active/passive,
1 … 5 V (0 … 5 V)
Repeater power supply operation:
4 … 20 mA active/passive,
1…5V
4 … 20 mA (0 … 20 mA)
With line fault detection
T-Connector
Compatible
Configurable via DIP switch
Design width
12.5 mm
17.5 mm
12.5 mm
Screw
connection
MACX MCR-SL-RPSSI-2I
2924825
MACX MCR-SL-RPSSI-I-UP
2865968
MACX MCR-SL-IDSI-I
2865971
Push-in
connection
MACX MCR-SL-RPSSI-2I-SP
2924838
MACX MCR-SL-RPSSI-I-UP-SP
2924210
MACX MCR-SL-IDSI-I-SP
2924223
Versions with wide range input for worldwide power
supply networks (MACX MCR-…-UP).
The DIN rail connector enables the modular bridging of
the 24 V supply voltage.
T-Connector
Compatible
Bro IE MACX Analog DE.indd 7
PhOENIX CONTACT
7
Universal
Power Input
03.03.14 15:45
MACX Analog – product overview
Temperature
Temperature
SIL 2
T-Connector
Compatible
Temperature transducer for RTD sensors,
configurable
Temperature
SIL 2
T-Connector
Compatible
Temperature transducer for TC sensors,
configurable
SIL 2
Universal
Universal temperature transducer,Power Input
with limit value relay, configurable
IN
RTD: PT 50, PT 100, PT 200, PT 500,
PT 100S, PT 500S, Ni 100, Ni 500, Cu50,
Cu53
Potentiometer: 0 … 2000 Ω
Linear resistance: 0 … 2000 Ω
Configurable via ANALOG-CONF or
FDT/DTM
TC: type E, J, K, N, L
Voltages: -20 mV … 70 mV
Configurable via ANALOG-CONF or
FDT/DTM
RTD: PT 10 … PT 10000, Ni 10 … Ni 10000,
Cu10, Cu53, KTY
TC 1): type B, E, J, K, N, R, S, T, L, U, C, D,
A-1, A-2, A-3, M, L
Potentiometer: 0…50 kΩ
Linear resistance: 0…50 kΩ
±1000 mV, ±20 mA2)
Configurable via ANALOG-CONF,
FDT/DTM or IFS-OP-UNIT
OUT
0 … 20 mA, 4 … 20 mA (functionally safe)
Configurable via ANALOG-CONF or
FDT/DTM
0 … 20 mA , 4 … 20 mA (functionally safe)
Configurable via ANALOG-CONF or
FDT/DTM
Analog: 0 … 20 mA, -10 … 10 V (freely
scalable), 4 … 20 mA (functionally
safe)
Digital: 1 PDT relay
Configurable via ANALOG-CONF,
FDT/DTM or IFS-OP-UNIT
Design width
12.5 mm
12.5 mm
17.5 mm
Screw
connection
MACX MCR-SL-RTD-I-NC
2865078
MACX MCR-SL-TC-I-NC
2924346
MACX MCR-T-UI-UP
2811394
Push-in
connection
MACX MCR-SL-RTD-I-SP-NC
2924320
MACX MCR-T-UI-UP-SP
2811860
Temperature
SIL 2
Universal
Universal temperature transducer,Power Input
with three limit value relays, configurable
IN
RTD: PT 10 … PT 10000, Ni 10 … Ni 10000,
Cu10, Cu53, KTY
TC 1): type B, E, J, K, N, R, S, T, L, U, C, D,
A-1, A-2, A-3, M, L
Potentiometer: 0 … 50 Ω
Linear resistance: 0 … 50 kΩ
±1000 mV, ±20 mA2)
Configurable via ANALOG-CONF,
FDT/DTM or IFS-OP-UNIT
OUT
Analog: 0 … 20 mA, -10 … 10 V (freely
scalable), 4 … 20 mA (functionally
safe)
Digital: 3 relay outputs, combination of
relay 2 and 3 functionally safe
Configurable via ANALOG-CONF,
FDT/DTM or IFS-OP-UNIT
Design width
35.0 mm
Screw
connection
MACX MCR-T-UIREL-UP
2811378
Push-in
connection
MACX MCR-T-UIREL-UP-SP
2811828
8
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 8
1)
See accessory MACX MCR(-EX)-CJC
2)
See accessory MACX MCR(-EX)-I20
03.03.14 15:45
MACX Analog – product overview
Digital IN
Digital IN
Digital IN
SIL 2
SIL 2
NAMUR signal conditioner,
PDT output
T-Connector
Compatible
NAMUR signal conditioner,
two N/O contact outputs
SIL 2
T-Connector
Compatible
T-Connector
NAMUR signal conditioner, Compatible
two-channel, N/O contact output
IN
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
OUT
1 relay (PDT)
250 V AC (2 A), 120 V DC (0.2 A),
30 V DC (2 A)
Switching behavior configurable via
DIP switch
2 relays (N/O contacts)
250 V AC (2 A), 120 V DC (0.2 A),
30 V DC (2 A)
Switching behavior configurable via
DIP switch
1 relay (N/O contact) per channel
250 V AC (2 A) , 120 V DC (0.2 A),
30 V DC (2 A)
Switching behavior configurable via
DIP switch
Design width
Screw
connection
Push-in
connection
12.5 mm
12.5 mm
12.5 mm
MACX MCR-SL-NAM-2RO
2865010
MACX MCR-SL-2NAM-RO
2865049
MACX MCR-SL-NAM-R-SP
2924252
MACX MCR-SL-NAM-2RO-SP
2924265
MACX MCR-SL-2NAM-RO-SP
2924294
Digital IN
Digital IN
Digital IN
MACX MCR-SL-NAM-R
2865997
SIL 2
NAMUR signal conditioner,
two-channel, PDT output
SIL 2
SIL 2
Universal
Power Input
NAMUR signal conditioner,
two transistor outputs
T-Connector
Compatible
NAMUR signal conditioner,
two-channel, transistor output
T-Connector
Compatible
IN
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
OUT
1 relay (PDT) per channel
250 V AC (2 A) , 120 V DC (0.2 A),
30 V DC (2 A)
Switching behavior configurable via
DIP switch
2 transistor outputs, passive
Switching voltage/current: max.
30 V DC/50 mA
Switching frequency: max. 5 kHz
Switching behavior configurable via
DIP switch
1 transistor output per channel, passive
Switching voltage/current: max.
30 V DC/50 mA
Switching frequency: max. 5 kHz
Switching behavior configurable via
DIP switch
Design width
17.5 mm
12.5 mm
12.5 mm
Screw
connection
MACX MCR-SL-2NAM-R-UP
2865052
MACX MCR-SL-NAM-2T
2865023
MACX MCR-SL-2NAM-T
2865036
Push-in
connection
MACX MCR-SL-2NAM-R-UP-SP
2924304
MACX MCR-SL-NAM-2T-SP
2924278
MACX MCR-SL-2NAM-T-SP
2924281
Versions with wide range input for worldwide power
supply networks (MACX MCR-…-UP).
The DIN rail connector enables the modular bridging of
the 24 V supply voltage.
T-Connector
Compatible
Bro IE MACX Analog DE.indd 9
PhOENIX CONTACT
9
Universal
Power Input
03.03.14 15:45
Maximum explosion protection
MACX Analog Ex
Highly compact and leading technology:
with a design width of just 12.5 mm,
MACX Analog Ex offers a wide range of
single and two-channel signal isolators for
intrinsically safe circuits in the hazardous
area. The products are type-tested by
an independent NAMUR test laboratory
in accordance with NE 95 and therefore
satisfy the high requirements of the
chemical industry.
HART communication
Bidirectional transmission
of the HART
communication signal
for all analog IN and
analog OUT isolators.
Suitable for all Ex zones and gas groups
All MACX Analog Ex signal conditioners are approved in
accordance with the applicable ATEX and IECEx standards:
• Ex i – for intrinsically safe circuits up to zone 0 (gas) and
zone 20 (dust)
Marking:
X II (1) G [Ex ia Ga] IIC;
X II (1) D [Ex ia Da] IIIC
• Ex n – for device installation in zone 2
Marking:
X II 3(1) G Ex nA nC [ia Ga] IIC T4 Gc
Relevant national approvals such as UL and GOST are
available.
Fast diagnostics
LED indicators
according to NE 44
for supply voltage,
switching state, and
fault.
Hot-swappable module
replacement
Easy system expansion or
module replacement during
operation.
Easy-maintenance
connection terminal blocks
10
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 10
Plug-in, coded connection
terminal blocks with integrated
test sockets.
03.03.14 15:45
Power supply and diagnostics –
flexible and easy with the DIN rail connector
Easily bridge the 24 V supply voltage using the modular DIN rail connector.
This simplifies wiring and enables system expansion or module replacement
even during operation.
The DIN rail connector offers two supply options:
1.2
2.2
3.2
N.C.
N.C.
3.3
1.1
2.1
3.1
Power IN
PWR
PWR1
PWR2
ERR
OUT1
1
2
ON OFF
Group
error message
1.2
2.2
3.2
OUT2 1
2
3
4
4.1
5.1
1.1
2.1
3.1
PWR
OUT1
1.2
2.2
3.2
OUT2 1
2
3
4
I II
4.2
5.2
4.1
5.1
1.1
2.1
3.1
PWR
OUT1
1.2
2.2
3.2
OUT2 1
2
3
4
I II
4.2
5.2
4.1
5.1
1.1
2.1
3.1
PWR
OUT1
1.2
2.2
3.2
OUT2 1
2
3
4
I II
4.2
5.2
4.1
5.1
1.1
2.1
3.1
PWR
OUT1
1.2
2.2
3.2
OUT2 1
4.2
5.2
4.1
5.1
PWR
OUT1
1.2
2.2
3.2
OUT2 1
2
3
4
I II
1.1
2.1
3.1
MACX MCR-EX-SL-NAM-2RO
1.1
2.1
3.1
Power supply,
redundant
MACX MCR-EX-SL-NAM-2RO
3.3
MACX MCR-EX-SL-NAM-2RO
3.2
MACX MCR-EX-SL-NAM-2RO
Power and fault
monitoring module
3.1
MACX MCR-EX-SL-NAM-2RO
Fault monitoring
contact
MACX MCR-EX-SL-NAM-2RO
Precise and interference-free signal
transmission, thanks to the patented
transmitter concept with safe electrical
isolation.
1. Direct supply
Via any MACX Analog Ex module
MACX MCR-PTB
Precise, interference-free signal
transmission
2
3
4
I II
4.2
5.2
4.1
5.1
I II
4.2
5.2
2. Via the power and fault monitoring module
• Simple or redundant supply (decoupled from diode)
• Fault monitoring output (message in the event of auxiliary
voltage failure and line fault group message in the case of
NAMUR signal conditioners)
Long service life and high operational
reliability
Long service life and high operational
reliability over the entire operating
temperature range, thanks to low power
consumption and self-heating.
Maximum explosion protection with minimum space
requirements
With a housing width of just 12.5 mm for all single and two-channel 24 V
devices, MACX Analog Ex offers space savings of up to 45% compared to
other Ex i signal conditioners on the market.
125 mm
45% space saving
Fast and error-free signal connection
Compact Termination Carriers connect
MACX Analog Ex devices to the automation
system easily by means of plug and play.
160 mm
200 mm
225 mm
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 11
11
03.03.14 15:45
MACX Analog Ex – product overview
Analog IN
Analog IN
Analog IN
SIL 2
SIL 2
POWER
IN
POWER
IN
I
I
OUT
I
I
OUT
SIL 3
POWER
T-Connector
IN
OUT
T-Connector
Compatible
Repeater power supply and input signal
conditioner,
HART-compatible
Input isolator operation:
4 … 20 mA (0 … 20 mA)
Compatible
Repeater power supply and input signal
conditioner with two outputs,
HART-compatible
Input isolator operation:
4 … 20 mA (0 … 20 mA)
Repeater power supply operation:
4 … 20 mA
Transmitter supply voltage:
> 16 V (20 mA)
Repeater power supply operation:
4 … 20 mA
Transmitter supply voltage:
> 16 V (20 mA)
Input isolator operation:
4 … 20 mA (0 … 20 mA) active/passive
Input isolator operation:
4 … 20 mA (0 … 20 mA) per output, active
Repeater power supply operation:
4 … 20 mA active/passive
Repeater power supply operation:
4 … 20 mA per output, active
Design width
T-Connector
Compatible
Repeater power supply,
two-channel, HART-compatible
4 … 20 mA per channel
Transmitter supply voltage:
> 16 V (20 mA) per channel
4 … 20 mA per channel, active
12.5 mm
12.5 mm
12.5 mm
Screw
connection
MACX MCR-EX-SL-RPSSI-I
2865340
MACX MCR-EX-SL-RPSSI-2I
2865366
MACX MCR-EX-SL-RPSS-2I-2I
2865382
Push-in
connection
MACX MCR-EX-SL-RPSSI-I-SP
2924016
MACX MCR-EX-SL-RPSSI-2I-SP
2924236
MACX MCR-EX-SL-RPSS-2I-2I-SP
2924676
Analog IN
Analog OUT
SIL 2
SIL 2
OUT
Universal
Power Input
Repeater power supply and input signal
conditioner,
HART-compatible
Input isolator operation:
4…20 mA (0…20 mA)
IN
I
I
IN
POWER
Output signal conditioner,
HART-compatible
T-Connector
Compatible
4 … 20 mA (0 … 20 mA)
With cable break detection
Repeater power supply operation:
4…20 mA
Transmitter supply voltage:
> 16 V (20 mA)
OUT
Input isolator operation:
4 … 20 mA (0 … 20 mA) active/passive,
1 … 5 V (0 … 5 V)
4 … 20 mA (0 … 20 mA)
With cable break detection
Repeater power supply operation:
4 … 20 mA active/passive,
1…5V
Can be set via DIP switch
Design width
17.5 mm
12.5 mm
Screw
connection
MACX MCR-EX-SL-RPSSI-I-UP
2865793
MACX MCR-EX-SL-IDSI-I
2865405
Push-in
connection
MACX MCR-EX-SL-RPSSI-I-UP-SP
2924029
MACX MCR-EX-SL-IDSI-I-SP
2924032
12
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 12
1)
See accessory MACX MCR(-EX)-CJC
2)
See accessory MACX MCR(-EX)-I20
03.03.14 15:45
MACX Analog Ex – product overview
Temperature
Temperature
Temperature
SIL 2
SIL 2
T-Connector
Compatible
Temperature transducer for RTD sensors,
configurable
Temperature transducer for
TC sensors, configurable
SIL 2
T-Connector
Compatible
Universal
Universal temperature transducer,Power Input
with limit value relay, configurable
IN
RTD: PT 50, PT 100, PT 200, PT 500,
PT 100S, PT 500S, Ni 100, Ni 500, Cu50,
Cu53
Potentiometer: 0 … 2000 Ω
Linear resistance: 0 … 2000 Ω
Configurable via ANALOG-CONF or
FDT/DTM
TC: type E, J, K, N, L
Voltages: -20 mV … 70 mV
Configurable via ANALOG-CONF or
FDT/DTM
RTD: PT 10 … PT 10000, Ni 10 … Ni 10000,
Cu10, Cu53, KTY
TC 1): type B, E, J, K, N, R, S, T, L, U, C, D,
A-1, A-2, A-3, M, L
Potentiometer: 0 … 50 kΩ
Linear resistance: 0 … 50 kΩ
±1000 mV, ±20 mA2)
Configurable via ANALOG-CONF,
FDT/DTM or IFS-OP-UNIT
OUT
0 … 20 mA , 4 … 20 mA
Configurable via ANALOG-CONF or
FDT/DTM
0 … 20 mA , 4 … 20 mA
Configurable via ANALOG-CONF or
FDT/DTM
Analog: 0 … 20 mA, -10 … 10 V (freely
scalable), 4 … 20 mA (functionally
safe)
Digital: 1 PDT relay
Configurable via ANALOG-CONF,
FDT/DTM or IFS-OP-UNIT
Design width
12.5 mm
12.5 mm
17.5 mm
Screw
connection
MACX MCR-EX-SL-RTD-I-NC
2865573
MACX MCR-EX-SL-TC-I-NC
2865586
MACX MCR-EX-T-UI-UP
2865654
Push-in
connection
MACX MCR-EX-SL-RTD-I-SP-NC
2924168
MACX MCR-EX-T-UI-UP-SP
2924689
Temperature
SIL 2
U,I
IN
OUT
POWER
3x
Universal
Universal temperature transducer,Power Input
with 3 limit value relays, configurable
IN
RTD: PT 10 … PT 10000, Ni 10 … Ni 10000,
Cu10, Cu53, KTY
TC 1): type B, E, J, K, N, R, S, T, L, U, C, D,
A-1, A-2, A-3, M, L
Potentiometer: 0 … 50 kΩ
Linear resistance: 0 … 50 kΩ
±1000 mV, ±20 mA2)
Configurable via ANALOG-CONF,
FDT/DTM or IFS-OP-UNIT
OUT
Analog: 0 … 20 mA, -10 … 10 V (freely
scalable), 4 … 20 mA (functionally
safe)
Digital: 3 relay outputs, combination of
relay 2 and 3 functionally safe
Configurable via ANALOG-CONF,
FDT/DTM or IFS-OP-UNIT
Design width
35.0 mm
Screw
connection
MACX MCR-EX-T-UIREL-UP
2865751
Push-in
connection
MACX MCR-T-UIREL-UP-SP
2924799
The DIN rail connector enables the modular bridging of
the 24 V supply voltage.
T-Connector
Compatible
Bro IE MACX Analog DE.indd 13
Versions with wide range input for worldwide power
supply networks (MACX MCR-EX-…-UP).
PhOENIX CONTACT
13
Universal
Power Input
03.03.14 15:45
MACX Analog Ex – product overview
Digital IN
Digital IN
NAMUR signal conditioner,
PDT output
T-Connector
Compatible
Digital IN
SIL 2
SIL 2
SIL 2
NAMUR signal conditioner,
2 N/O contact outputs
T-Connector
Compatible
T-Connector
NAMUR signal conditioner, Compatible
two-channel, N/O contact output
IN
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
OUT
1 relay (PDT)
250 V AC (2 A), 120 V DC (0.2 A),
30 V DC (2 A)
Switching behavior configurable via
DIP switch
2 relays (N/O contacts)
250 V AC (2 A), 120 V DC (0.2 A),
30 V DC (2 A)
Switching behavior configurable via
DIP switch
1 relay (N/O contact) per channel
250 V AC (2 A), 120 V DC (0.2 A),
30 V DC (2 A)
Switching behavior configurable via
DIP switch
Design width
12.5 mm
12.5 mm
12.5 mm
Screw
connection
MACX MCR-EX-SL-NAM-R
2865434
MACX MCR-EX-SL-NAM-2RO
2865450
MACX MCR-EX-SL-2NAM-RO
2865476
Push-in
connection
MACX MCR-EX-SL-NAM-R-SP
2924045
MACX MCR-SL-EX-NAM-2RO-SP
2924061
MACX MCR-EX-SL-2NAM-RO-SP
2924087
Digital IN
Digital IN
Digital IN
SIL 2
NAMUR signal conditioner,
two-channel, PDT output
Universal
Power Input
SIL 2
T-Connector
NAMUR signal conditioner, Compatible
single-channel, 2 transistor outputs
SIL 2
NAMUR signal conditioner,
two-channel, transistor output
T-Connector
Compatible
IN
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
NAMUR proximity sensors
Unused contacts or contacts with resistance
circuit
Line fault detection can be switched on/off
OUT
1 relay (PDT) per channel
250 V AC (2 A), 120 V DC (0.2 A),
30 V DC (2 A)
Switching behavior configurable via
DIP switch
2 transistor outputs, passive
Switching voltage/current:
max. 30 V DC/50 mA
Switching frequency: max. 5 kHz
Switching behavior configurable via
DIP switch
1 transistor output per channel, passive
Switching voltage/current:
max. 30 V DC/50 mA
Switching frequency: max. 5 kHz
Switching behavior configurable via
DIP switch
Design width
17.5 mm
12.5 mm
12.5 mm
Screw
connection
MACX MCR-EX-SL-2NAM-R-UP
2865984
MACX MCR-EX-SL-NAM-2T
2865463
MACX MCR-EX-SL-2NAM-T
2865489
Push-in
connection
MACX MCR-EX-SL-2NAM-R-UP-SP
2924249
MACX MCR-EX-SL-NAM-2T-SP
2924074
MACX MCR-EX-SL-2NAM-T-SP
2924090
14
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 14
03.03.14 15:45
MACX Analog Ex – product overview
Digital IN
Digital OUT
SIL 2
-
OUT
OUT
+
IN
Digital OUT
SIL 3
SIL 3
IN
+
POWER
NAMUR signal conditioner,
output with resistive behavior,
with line fault transparency
POWER
T-Connector
Compatible
T-Connector
Solenoid driver, with logic input and Compatible
line
fault detection, current limitation at 48 mA
Solenoid driver, loop-powered,
current limitation at 25 mA
IN
Switching level 0 signal (“L”): 0 … 5 V DC
20 … 30 V DC, 10 … 70 mA DC
NAMUR proximity sensors
Unused contacts or contacts with resistance Switching level 1 signal (“H”): 15 … 30 V DC (45 mA at Ue = 24 V DC)
circuit
Line fault detection can be switched on/off
OUT
Resistive behavior according to
EN 60947-5-6
Switching voltage: 8.2 V DC
Switching frequency: max. 5 kHz
Switching behavior configurable via
DIP switch
Design width
9.5 V DC (at 48 mA)
Current limitation: 48 mA
Off-load voltage:
23 V DC
Internal resistance: 269 Ω
With line fault transparency and additional
fault monitoring output
T-Connector
Compatible
5.5 V DC (at 25 mA)
Current limitation: 25 mA
Off-load voltage:
21.9 V DC
Internal resistance: 641 Ω
12.5 mm
12.5 mm
12.5 mm
Screw
connection
MACX MCR-EX-SL-NAM-NAM
2866006
MACX MCR-EX-SL-SD-23-48-LFD
2924867
MACX MCR-EX-SL-SD-21-25-LP
2865492
Push-in
connection
MACX MCR-EX-SL-NAM-NAM-SP
2924883
MACX MCR-EX-SL-SD-23-48-LFD-SP
2924870
MACX MCR-EX-SL-SD-21-25-LP-SP
2924113
Digital OUT
Digital OUT
Digital OUT
SIL 3
SIL 3
SIL 3
T-Connector
T-Connector
Solenoid driver, loop-powered, Compatible
current limitation at 40 mA
Solenoid driver, loop-powered, Compatible
current limitation at 48 mA
Solenoid driver, loop-powered,
current limitation at 58 mA
IN
20 … 30 V DC, 10 … 95 mA DC
(65 mA at Ue = 24 V DC)
20 … 30 V DC, 10 … 95 mA DC
(75 mA at Ue = 24 V DC)
20 … 30 V DC, 10 … 105 mA DC
(95 mA at Ue = 24 V DC)
OUT
10 V DC (at 40 mA)
Current limitation: 40 mA
Off-load voltage:
21.9 V DC
Internal resistance: 287 Ω
10.5 V DC (at 48 mA)
Current limitation: 48 mA
Off-load voltage:
24 V DC
Internal resistance: 276 Ω
12.9 V DC (at 58 mA)
Current limitation: 58 mA
Off-load voltage:
21.9 V DC
Internal resistance: 133 Ω
Design width
T-Connector
Compatible
12.5 mm
12.5 mm
12.5 mm
Screw
connection
MACX MCR-EX-SL-SD-21-40-LP
2865764
MACX MCR-EX-SL-SD-24-48-LP
2865609
MACX MCR-EX-SL-SD-21-60-LP
2865515
Push-in
connection
MACX MCR-EX-SL-SD-21-40-LP-SP
2924139
MACX MCR-EX-SL-SD-24-48-LP-SP
2924126
MACX MCR-EX-SL-SD-21-60-LP-SP
2924100
The DIN rail connector enables the modular bridging of
the 24 V supply voltage.
T-Connector
Compatible
Bro IE MACX Analog DE.indd 15
Versions with wide range input for worldwide power
supply networks (MACX MCR-EX-…-UP).
PhOENIX CONTACT
15
Universal
Power Input
03.03.14 15:45
Analog signals
with performance level
MACX Safety
Integrate analog signals easily into your
safety application according to the
Machinery Directive. The MACX Safety
analog signal conditioners are certified
according to EN ISO 13849-1 with
performance level PL d.
MACX Safety Ex also supports the safe
processing of analog, intrinsically safe
Ex signals.
MACX Safety and MACX Safety Ex offer the
following advantages:
• Easy integration of analog signals into the safety chain,
thanks to the performance level, PL d
• Direct, safe switching of limit values possible without
an additional safety controller
• Easy planning of the safety application via SISTEMA
• Easy to combine active or passive analog signals with
other safety modules
• Safe processing of intrinsically safe Ex signals with
MACX Safety Ex [Ex ia]
Ex approvals according to
ATEX, IECEx
• Ex i for intrinsically safe
circuits up to zone 0 and
zone 20
• Ex n for installation in
zone 2
Easy-maintenance
connection terminal blocks
16
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 16
Plug-in, coded connection
terminal blocks with integrated
test sockets.
03.03.14 15:45
MACX Safety – product overview
Analog IN
Temperature
SIL 2
PL d
SIL 2
PL d
I
IN
OUT
POWER
T-Connector
Compatible
Repeater power supply and input signal
conditioner with two outputs,
HART-compatible
Universal
Universal temperature transducer,Power Input
with limit value relay, configurable
IN
Input isolator operation:
4 … 20 mA
Repeater power supply operation:
4 … 20 mA
Transmitter supply voltage:
> 16 V (20 mA)
RTD: PT 10 … PT 10000, Ni 10 … Ni 10000,
Cu10, Cu53, KTY
TC 1): type B, E, J, K, N, R, S, T, L, U, C, D,
A-1, A-2, A-3, M, L
Potentiometer: 0 … 50 kΩ
Linear resistance: 0 … 50 kΩ
±1000 mV, ±20 mA2)
Configurable via ANALOG-CONF or FDT/
DTM
OUT
Input isolator operation:
4 … 20 mA per output, active
Repeater power supply operation:
4 … 20 mA per output, active
Analog: 4…20 mA, active
Digital: Combination of relay 2 and 3,
functionally safe,
1 additional relay output
Configurable via ANALOG-CONF or
FDT/DTM
Design width
12.5 mm
35.0 mm
Screw
connection
MACX PL-RPSSI-2I
2904961
MACX PL-T-UIREL-UP
Push-in
connection
MACX PL-RPSSI-2I-SP
2904962
MACX PL-T-UIREL-UP
2904901
2904903
MACX Safety Ex – product overview
Analog IN
Analog IN
SIL 2
PL d
POWER
IN
POWER
IN
I
I
I
I
Temperature
SIL 3
PL d
OUT
OUT
Repeater power supply and input signal
conditioner with two outputs, HARTcompatible
IN
Input isolator operation:
4…20 mA
Repeater power supply operation:
4…20 mA
Transmitter supply voltage:
> 16 V (20 mA)
OUT
Input isolator operation:
4 … 20 mA per output, active
Repeater power supply operation:
4 … 20 mA per output, active
Design width
OUT
POWER
POWER
T-Connector
Compatible
SIL 2
PL d
I
IN
T-Connector
Compatible
Universal
Universal temperature transducer,Power Input
with limit value relay, configurable
Repeater power supply, two-channel,
HART-compatible
Repeater power supply operation:
4 … 20 mA per channel
Transmitter supply voltage:
> 16 V (20 mA) per channel
RTD: PT 10 … PT 10000, Ni 10 … Ni 10000,
Cu10, Cu53, KTY
TC 1): type B, E, J, K, N, R, S, T, L, U, C, D,
A-1, A-2, A-3, M, L
Potentiometer: 0 … 50 kΩ
Linear resistance: 0 … 50 kΩ
±1000 mV, ±20 mA2)
Configurable via ANALOG-CONF or
FDT/DTM
Repeater power supply operation:
4 … 20 mA per channel, active
Analog: 4…20 mA, active
Digital: Combination of relay 2 and 3,
functionally safe,
1 additional relay output
Configurable via ANALOG-CONF or
FDT/DTM
12.5 mm
12.5 mm
35.0 mm
Screw
connection
MACX PL-EX-RPSSI-2I
2904959
MACX PL-EX-RPSS-2I-2I
2904963
MACX PL-EX-T-UIREL-UP
2904910
Push-in
connection
MACX PL-EX-RPSSI-2I-SP
2904960
MACX PL-EX-RPSS-2I-2I-SP
2904964
MACX PL-EX-T-UIREL-UP-SP
2904912
1)
See accessory
MACX MCR(-EX)-CJC
2)
See accessory
MACX MCR(-EX)-I20
Bro IE MACX Analog DE.indd 17
The DIN rail connector enables the modular
bridging of the 24 V supply voltage.
T-Connector
Compatible
Universal
Power Input
Versions with wide range input for
worldwide power supply networks
(MACX MCR-EX-…-UP).
PhOENIX CONTACT
17
03.03.14 15:45
Consistent interface solutions
for system technology
Termination Carrier
160
mm
Using the compact Termination Carriers,
you can connect MACX Analog devices
to your automation system quickly and
without any errors. You can establish the
signal connection with standardized system
cables by means of plug and play.
The following standard DIN rail devices are
available for safe signal conditioning:
• Signal conditioners for Ex i circuits and
SIL applications
• Highly compact signal conditioners for
non-Ex i circuits
• Safe coupling relays for process
automation
The Termination Carrier concept
• Stable aluminum profile without pitch
markings with integrated DIN rail
contour for accommodating standard
interfaces
• PCB protected in the profile,
mechanically decoupled
• Integrated DIN rail mounting with end
bracket
• Module connection by means of plug-in
and coded cable sets
• Cover with marking options
Your consistent interface solution
for system technology
18
1. Select a standard module
2. Termination Carrier
Select the appropriate functions
for signal conditioning from
a wide range of standard
DIN rail devices.
Snap standard modules onto the
integrated DIN rail contour
in the profile. Connection to the
Termination Carrier PCB is quick and
safe with plug-in and coded cable sets.
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 18
03.03.14 15:45
Compact
170 mm
For high packing density
• Space savings of up to 30 %, thanks to the compact design
• Space-saving arrangement of connection points
• Integrated end brackets
Robust
For high system availability
• Stable and vibration-resistant aluminum carrier profile
• Mechanically decoupled termination PCB
• Passive PCB without active components
• Redundant supply and monitoring electronics
in a separate DIN rail device
242 mm
Easy maintenance
For simplified documentation and startup
• Use of standard DIN rail devices
• Easily accessible connection points
• Module replacement during operation (hot swappable)
• Pre-assembled system cabling with front adapter
Flexible
For optimum adaptation
• Profile sections without pitch markings for controller-specific
number of I/Os
• Different system plug types, including redundant
• Horizontal and vertical mounting
3. Front adapter with system cable
The devices are connected to
controller-specific I/O modules via highposition system cables. These cables have
standardized or controller-specific system
connections.
and others
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 19
19
03.03.14 15:45
Diagram of a typical system with point-to-point wiring
Hazardous area
Jumpering level
Process control level
20
Interface level
17
18
19
20
Distributor boxes
20
Field devices
Non-hazardous area
16
Output DC 40A
Output DC 24 V 10 A
Output DC 24 V 10 A
15
13 14 - - DC
Ι<
+ + +
OK
Ι
13 14 - - DC
Ι<
+ + +
OK
Ι
N
13
14
N
QUINT POWER
QUINT POWER
11
10
9
8
7
Boost
DC OK
18-29.5 V
Input AC 100-240 V
N
L
IN 1
IN 2
Input DC 12-24V 2x20A
N
15
16
17
18
19
20
1
2
3
4
5
6
L
QUINT DIODE
12
Boost
DC OK
18-29.5 V
Input AC 100-240 V
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
2
3
4
5
6
7
8
9
10
11
12
13
14
1
1
CH
16
17
CH
13
18
CH
14
19
20
CH
15
16
CH
12
15
CH
11
CH
12
11
10
9
8
7
CH
13
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
CH
11
6
CH
14
5
System
cable
CH
15
4
Master
cable
CH
16
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
11
12
CH
09
13
14
CH
10
Master cable
6
CH
15
5
CH
14
2
CH
12
3
4
CH
13
1
CH
11
Alarm
7
PW
P
W2
W
PW2
PW1
4
5
6
PW
1
X20
0
8
9
10
11
12
13
14
15
16
17
CH
08
18
CH
09
19
20
CH
10
1
CH
15
2
3
CH
16
20
CH
14
19
CH
13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
CH
12
In the hazardous area, cables from intrinsically safe field devices
are grouped together via distributor boxes to form multi-strand
master cables. In the non-hazardous area, they are then routed to
the interface level via marshalling distributors. From here the signal
conditioners are individually wired to the relevant I/O cards. The
significant amount of time needed for installation and startup is
greatly reduced by the Termination Carrier and the use of plug
and play system cables.
Modular power concept for high availability
X20
Alarm
CH
01
PW PW
2
1
PW2 PW1
Connection for
supply and
fault monitoring
output
CH
07
CH
08
CH
09
CH
12
CH
11
CH
10
MACX Analog Ex
signal conditioner
CH
06
CH
05
CH
04
CH
03
N.C.
N.C.
3.3
ON O
O
OFF
FFF
MACX MCR-PTB
CH
02
1.2
2.2
3.2
1
2
Power and fault
monitoring module
1.1
2.1
3.1
PWR1
ERR
The termination PCB is therefore passive. It does not
contain any active components whose failure would
require the Termination Carrier to be replaced.
1 2 3 4 5
PWR2
The signal conditioners are connected to a power
and fault monitoring module via the integrated DIN
rail connectors. This enables redundant supply and
monitoring electronics in a separate device.
CH
16
CH
15
CH
14
CH
13
DIN rail
connectors
6 7 8 9 10
0
20
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 20
03.03.14 15:46
Efficient signal connection with
MACX Analog Ex
In areas of process technology where potentially explosive
atmospheres may occur, measuring and control circuits
are usually designed with intrinsic safety protection type
(Ex i). MACX Analog Ex i signal conditioners and measuring
transducers isolate intrinsically safe circuits from nonintrinsically safe circuits at the interface level and safely limit
the energy supplied to the hazardous area. Furthermore, they
handle extensive signal conditioning tasks.
Space-saving and
fast installation
The compact Termination Carrier
solution enables you to integrate up to
384 signals in an 80 x 200 cm control
cabinet when using two-channel
MACX Analog Ex devices.
Mounting and startup can be carried
out quickly and without any errors using
pre-assembled system cables.
Termination Carriers
In addition to universal
Termination Carriers, numerous
versions are available which are
tailored to the I/O modules of
various automation systems.
Please contact us for more
information.
TC-D37SUB-ADIO16-EX-P-UNI
Order No. 2924854
TC-D37SUB-AIO16-EX-PS-UNI
Order No. 2902932
Universal Termination Carrier for
16 MACX MCR(-EX) isolators.
Universal Termination Carrier for
16 MACX MCR(-EX) isolators with
connection for HART multiplexer.
and others
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 21
21
03.03.14 15:46
Accessories for MACX Analog
Operator interface
Programming adapter
DIN rail connector
IFS-OP-UNIT
Order No. 2811899
MACX-USB-PROG-ADAPTER
Order No. 2811271
ME 6,2 TBUS-2 1,5/5-ST-3.81 GN
Order No. 2869728
For process value display and
parameterization, can be plugged
directly onto 35 mm devices and the
IFS-OP-CRADLE cradle unit.
For programming the multifunctional devices
with the ANALOG-CONF software or via
FDT/DTM.
For direct supply via any MACX Analog
device or for supply via a power and fault
monitoring module of the same shape.
IFS-OP-CRADLE
Order No. 2811886
Cradle for IF-OP-UNIT for connection
to 17.5 mm/35 mm modules and use as a
remote display unit.
Power and fault monitoring
module
Dummy module
MACX MCR-PTB
Order No. 2865625 (screw connection)
MACX MCR-EX-DUMMY-ISOLATOR
MACX MCR-PTB-SP
Order No. 2924184 (push-in connection)
MACX MCR-EX-DUMMY-ISOLATOR-SP
Order No. 2905846 (push-in connection)
• Input voltage
UIN: 19.2 … 30 V DC
• Output voltage
UOUT: UIN - max. 0.8 V, at 3.75 A
• Error message - PDT relay
Intrinsically safe dummy module with no
electrical function for connecting unused
signal cables.
22
Order No. 2904970 (screw connection)
Function plug
MACX MCR-CJC
Order No. 2924993
MACX MCR-EX-CJC Order No. 2925002
Plug for cold junction compensation for
thermocouples, in combination with
MACX…-(EX)-T-UI… temperature
transducers.
MACX MCR-I20
MACX MCR-EX-I20
Order No. 2905680
Order No. 2905679
Connection terminal block for current signals
(±20 mA) for safe switching of limit values,
in combination with MACX…-(EX)-T-UI…
temperature transducers.
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 22
03.03.14 15:46
Accessories for MACX Analog
Multiplexer for HART signals
HART transfer board
Shield fast connection
MACX MCR-S-MUX
Order No. 2865599
MACX MCR-S-MUX-TB
Order No. 2308124
SSA 3-6 (for Ø 3 - 6 mm)
Order No. 2839295
Multiplexer for the digital connection of
HART-compatible field devices, such as
measuring transducers or control valves, to
a PC or a management system, 32-channel,
including 14-wire flat-ribbon cable.
Transfer board for connecting HART field
devices to the HART multiplexer.
SSA 5-10 (Ø 5 - 10 mm)
Order No. 2839512
PSM-ME-RS232/RS485-P
Order No. 2744416
For connecting cable shielding to cable
terminal points, can be connected to
PLUGTRAB PT.
Electrically isolated interface converter for
converting from RS-232 (V.24) to RS-485.
Automatic data direction changeover or via
RTS/CTS.
Marking material
UC-EMLP (11X9) (white)
Order No. 0819291
Self-adhesive plastic labels for device marking:
UniCard, 10-section, lettering field size:
11 x 9 mm.
UC-EMLP (11X9) CUS (white)
Order No. 0824547
As above, plus marked according to your
specifications.
For details, visit www.phoenixcontact.com.
Test plug
Resistance circuit
MPS-MT
Order No. 0201744
UKK 5-2R/NAMUR
MPS-IH
MPS-IH
MPS-IH
MPS-IH
MPS-IH
MPS-IH
MPS-IH
Order
Order
Order
Order
Order
Order
Order
D-UKK 3/5 (gray)
Order No. 2770024
D-UKK 3/5 BU (blue) Order No. 2770105
BK (black)
GY (gray)
GN (green)
YE (yellow)
BU (blue)
RD (red)
WH (white)
No.
No.
No.
No.
No.
No.
No.
Test plug for 2.3 mm Ø socket hole,
consisting of MPS-MT metal part and
MPS-IH… color insulating sleeve.
0201731
0201728
0201702
0201692
0201689
0201676
0201336
Order No. 2941662
Double-level terminal block with resistance
circuit according to NAMUR for line fault
detection in the case of mechanical contacts.
Important: for intrinsically safe circuits, only
in combination with D-UKK 3/5... cover.
PhOENIX CONTACT
Bro IE MACX Analog DE.indd 23
23
03.03.14 15:46
Always up-to-date, always available to you. Here
you'll find everything on our products, solutions
and service:
phoenixcontact.com
Product range
• Industrial communication technology
• Industrial Ethernet
• Installation and mounting material
• Lighting and signaling
• Marking and labeling
• Measurement and control technology
• Modular terminal blocks
• Monitoring
• PCB terminal blocks and
PCB connectors
• Power supply units and UPS
• Protective devices
• Relay modules
• Sensor/actuator cabling
• Software
• Surge protection and interference filters
• System cabling for controllers
• Tools
• Wireless data communication
PHOENIX CONTACT GmbH & Co. KG
32825 Blomberg, Germany
Phone: +49 (0) 52 35 3-00
Fax:
+49 (0) 52 35 3-4 12 00
phoenixcontact.com
Bro IE MACX Analog DE.indd 24
IF 04-14.000.L3
MNR 52006465/2014-04-01/02
Printed in Germany