CLAMP ON AC/DC HiTESTER 3284, 3285/-20

CLAMP ON AC/DC HiTESTER
3284 [200A rms, ø 33mm max.]
3285/-20 [2000A rms, ø 55mm
(1.30")
(2.17") max.]
2000 A analysis
Field measuring instruments
(3285 /3285-20)
3284
3285-20
CAT III 600 V
3285
Analysis for
DC to distorted
waves
Analysis applications
Waveform harmonic
and
Supporting a wealth of functions
Inrush current
BNC TO BANANA
ADAPTER
9199
MEMORY HiCORDER
8807-51
crest value
OUTPUT CORD
9094
The peak hold function displays
the crest value of the inrush
current occurring when electrical
equipment is started.
Using the external output functions of the 3284 or 3285 in combination
with a HIOKI MEMORY HiCORDER enables recording of current
and frequency fluctuations and recording and harmonic analysis of
instantaneous waveforms. The monitor output (MON) spans a wide
frequency range from DC to 20 kHz (15 kHz in the case of 3285), which
allows the units to be used for electric current analysis in various fields
ranging from batteries to inverters.
Example of analysis using the MEMORY HiCORDER
RMS value of
full-wave rectified waveforms
current waveform
(inverter output )
▼
The AC+DC mode enables
measurement of the RMS value
of full- or half-wave rectified
waveforms used in electrical
machinery.
▲
current fluctuations
■ 3284 / 3285 Specifications
Voltage
(V)
Frequency (Hz)
*8
Resistance(W)
Continuity Check*8
DC
AC
Display Switch*1
Average / PEAK
RMS / PEAK
RMS / PEAK
[ ] in the Specification :3285,3285-20
Accuracy at 23 ˚C ± 5 ˚C (73 ˚F ± 9 ˚F), 80% rh or less.
Measurement accuracy applies to input of at least 5% of the current range, and at least 10% of the voltage/frequency range.
Range
20.00 / 200.0
[200.0 / 2000]
Resolution is
0.1 [1] A during PEAK
Average / PEAK 30.00 / 300.0 / 600
RMS / PEAK
AC+DC RMS / PEAK
▲
Harmonic analysis
Function Mode
DC
Current
AC
(A)
AC+DC
analysis
Model 3284 and 3285 only
Resolution is decreased by
1 digit except in the 600 V
range during PEAK
10.00 / 100.0/1000
1000/10.00k
1000
Accuracy at DC or 45 to 66 Hz
±1.3%rdg.±3dgt.
10 to 45Hz or 66 to 2 [ 1 ] kHz PEAK accuracy at DC or 45 to 66 Hz
±1.3%rdg.±3dgt.*2
±2.0%rdg.±5dgt.*3 *4
*2
*3*4
±1.3%rdg.±13dgt.
±2.0%rdg.±7dgt.
±1.0%rdg.±3dgt.
±1.0%rdg.±3dgt.
±1.5%rdg.±5dgt.
±1.0%rdg.±7dgt.
±1.5%rdg.±7dgt.
*5
±0.3%rdg.±1dgt.
±1.3%rdg.±7dgt.
Notes
Max. allowable current
*6
*5
±1.3%rdg.±7dgt.*6
200Arms cont. 300A peak max.
*6
[2000Arms cont. 2840A peak max.]
±1.3%rdg.±7dgt.
±1.0%rdg.±7dgt.
±1.0%rdg.±7dgt.
*7
±1.0%rdg.±7dgt.
±1.0%rdg.±1dgt. (at 1000Hz)
±1.5%rdg.±5dgt.
Threshold level 30W ±5W or less
Max. allowable voltage
600Vrms cont. 1000V peak max.
*7
Effective in the V and A functions
Open terminal Voltage 3.1V DC or less
*1 The peak hold function works automatically during PEAK measurement. *2 Add ±1.0% rdg. in the 1800 to 2000 A interval for the 3285. *3 Add ±1.0% rdg. in the 1k to 2kHz interval
for the 3284. *4 No assured accuracy in the 1800 to 2000 A interval for the 3285. *5 Add 6 dgt. in the 30 V range. *6 Add ±4.7% rdg. in the 2300 to 2840 A interval for the 3285. *7 Add ±
1.0%rdg.±13dgt when measuring 700 V to 1000V with Model 3285-20. *8 Model 3285-20 only.
Measurable conductor diameter : ø33 (1.30") mm, [ø55 (2.17") mm] max.
Max. usable circuit voltage : 600Vrms (insulated conductor)
Functions : recording (MAX. MIN. AVE) ,data hold, auto power-off, auto zero
Display update rate : digital indication FAST approx. 4 times/second, NORMAL approx. 2 times/second,
SLOW 1 time/ 3 seconds; bar graph indication approx. 4 times/second
Display response time : 1 sec or less
Range switching : Auto/Manual (Except resistance.)
Frequency characteristic : 40 Hz to 2 [1] kHz accuracy
External output : A/Hz only: recording output DC1V/f.s. ±1.3% rdg.±10mV, Response: 250ms
(Except model 3285-20) or less (at 0➞90%)/ MON A only : Waveform output 1Vrms/f.s. ±1.3% rdg.±5mV,
Frequency band: DC to 20 [15] kHz ±3dB
CLAMP ON AC/DC HiTESTER 3284
CLAMP ON AC/DC HiTESTER 3285
CLAMP ON AC/DC HiTESTER 3285-20
(All include TEST LEADS 9207-10, CARRYING CASE 9399(3284), CARRYING CASE 9345(3285/3285-20), HAND STRAP)
Effect of conductor position : within ±0.5[0.7] % in any direction from the center of sensor
Effect of external magnetic field : 400A/m corresponds to 0.5 [2] A max.
Crest factor : 2.5 or less, 1.7 or less in the 600 V range, 3284 is 1.5 or less in the 200A range [1.42 or less in the 2000A range]
Safety standard : EN61010 CAT III 600V, EN60529 IP40
EMC : EN61326, EN61000-3-2, EN61000-3-3
Ambient temperature of use : 0 to 40˚C (32˚F to 104˚F), 80%rh or less (no condensation)
Storage temperature range : -10 to 50˚C (14˚F to 122˚F) or less (no condensation)
Power supply : AC ADAPTER 9445(Except Model 3285-20.) or 6F22 manganese battery×1
(continuous operation : Model 3284/3285-25 hours, Model 3285-20-20 hours)
Dimensions and mass : Approx. 62W×230[260]H×39D mm, 460 [540]g
(Approx 2.45" W× 9.06 [10.3]" H× 1.54" D, 16.3 [19.1] oz.)
Options
AC ADAPTER (UL) 9445-02
AC ADAPTER (EU) 9445-03
*
An AC Adapter can only be used with Models 3284 and 3285.
OUTPUT CORD(Jack to banana plug) 9094
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong
Road, Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: [email protected]
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: [email protected]
*No CE marking
DISTRIBUTED BY
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
Room A-3206, Victory PlazaServices Center, No.103,
Tiyuxi Road, Guangzhou, P.R.China POSTCODE:510620
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
All information correct as of Feb. 12, 2010. All specifications are subject to change without notice.
3284E8-02B
Printed in Japan