PENCIL HiTESTER 3246

PENCIL HiTESTER 3246
Field measuring instruments
CAT IV 300 V
CAT III 600 V
Backlight LCD is highly visible,
even in dark locations
✦ 600 V circuit protection
makes fuses unnecessary
Penlight brightly
illuminates test points
✦ Comes with protective probe tip cap
Actual-size
✦ Test lead fits neatly into back of instrument
■ Specifications (Accuracy at 23˚C ± 5˚C (73˚F ± 9˚F), 80 % rh or less)
Function
DC voltage
AC voltage
50 to 500 Hz
Range (Accuracy)
419.9 m / 4.199 / 41.99 / 419.9 / 600 V
(Basic accuracy: ± 1.3 % rdg. ± 4 dgt.)
4.199 / 41.99 / 419.9 / 600 V
(Basic accuracy: ± 2.3 % rdg. ± 8 dgt.)
Average rectified
419.9 /4.199 k /41.99 k /419.9 k /4.199 M /41.99 MΩ
Resistance
Continuity
(Accuracy at range 419.9 Ω to 419.9 kΩ: ± 2.0 % rdg. ± 4 dgt.)
(Accuracy at range 4.199 MΩ: ±5.0 % rdg. ±4 dgt.)
(Accuracy at range 41.99 MΩ: ±10.0 % rdg. ±4 dgt.)
Open terminal voltage: 3.4 V max. at range 419.9 Ω, 0.7 V typ. at
4.199 kΩ, 0.5 V typ. at 41.99 kΩ to 41.99 MΩ
Buzzer sounds at a resistance 50 Ω ± 40 Ω or less
When used 419.9 Ω resistance range
Judge the forward direction identification
Diode check
Indicator flashes and buzzer sounds, open terminal voltage: 3.4 V or
less, and Testing current: 800 µA or less.
Works when diode has a forward voltage from 0.3 V to 2.0 V
PENCIL HiTESTER 3246
●Measurement system: average value rectification
●Display: Max.4199-count LCD
●Range switching: automatic or manual
●Ancillary functions: data hold function, auto power save function, battery life warning
function, penlight, backlight LCD
●Sampling rate: 2.5 times/sec
●Overload protection: 600 Vrms (sin) or 3 × 106 VHz for all functions
●Applicable standards: Safety - EN61010, EMC - EN61326
●Ambient temperature of use: 0 to 40˚C(32˚F to 104˚F), 80 % rh (no condensation)
●Storage temperature range: -20 to 60˚C (-4˚F to 140˚F), (no condensation)
●Power source: CR2032 battery × 1 (3V DC)
● Continuous operating time: approx. 150 hours (at DC V funtion), 30 hours (with
penlight turned on for 10 seconds and off for 20 seconds per cycle and in DC V function)
●Dimensions, mass: 30 mm (1.18 in)W × 182 mm (7.17 in)H × 26.5 mm (1.04 in)D, 80 g
(2.8 oz)
n Option
EXTERNAL SHUNT 9081
primary current: 10 A,
secondary voltage: 100 mV
HIOKI (Shanghai) Sales & Trading Co., Ltd. :
1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong
Road, Shanghai, P.R.China POSTCODE: 200021
TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360
E-mail: [email protected]
HEAD OFFICE :
81 Koizumi, Ueda, Nagano, 386-1192, Japan
TEL +81-268-28-0562 / FAX +81-268-28-0568
E-mail: [email protected]
HIOKI USA CORPORATION :
6 Corporate Drive, Cranbury, NJ 08512 USA
TEL +1-609-409-9109 / FAX +1-609-409-9108
E-mail: [email protected]
Output is 100mV at 10A. Multiply the displayed value by 1/10
and interpret the resulting value as current.
DISTRIBUTED BY
Beijing Office :
A-2602 Freetown, 58 Dong San Huan Nan Road
Beijing, P.R.China POSTCODE: 100022
TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090
E-mail: [email protected]
Guangzhou Office :
Room A-3206, Victory PlazaServices Center, No.103,
Tiyuxi Road, Guangzhou, P.R.China POSTCODE:510620
TEL +86-20-38392673/2676 FAX +86-20-38392679
E-mail: [email protected]
All information correct as of May. 1, 2009. All specifications are subject to change without notice.
3246E9-95B-00P
Printed in Japan