PENCIL HiTESTER 3246 Field measuring instruments CAT IV 300 V CAT III 600 V Backlight LCD is highly visible, even in dark locations ✦ 600 V circuit protection makes fuses unnecessary Penlight brightly illuminates test points ✦ Comes with protective probe tip cap Actual-size ✦ Test lead fits neatly into back of instrument ■ Specifications (Accuracy at 23˚C ± 5˚C (73˚F ± 9˚F), 80 % rh or less) Function DC voltage AC voltage 50 to 500 Hz Range (Accuracy) 419.9 m / 4.199 / 41.99 / 419.9 / 600 V (Basic accuracy: ± 1.3 % rdg. ± 4 dgt.) 4.199 / 41.99 / 419.9 / 600 V (Basic accuracy: ± 2.3 % rdg. ± 8 dgt.) Average rectified 419.9 /4.199 k /41.99 k /419.9 k /4.199 M /41.99 MΩ Resistance Continuity (Accuracy at range 419.9 Ω to 419.9 kΩ: ± 2.0 % rdg. ± 4 dgt.) (Accuracy at range 4.199 MΩ: ±5.0 % rdg. ±4 dgt.) (Accuracy at range 41.99 MΩ: ±10.0 % rdg. ±4 dgt.) Open terminal voltage: 3.4 V max. at range 419.9 Ω, 0.7 V typ. at 4.199 kΩ, 0.5 V typ. at 41.99 kΩ to 41.99 MΩ Buzzer sounds at a resistance 50 Ω ± 40 Ω or less When used 419.9 Ω resistance range Judge the forward direction identification Diode check Indicator flashes and buzzer sounds, open terminal voltage: 3.4 V or less, and Testing current: 800 µA or less. Works when diode has a forward voltage from 0.3 V to 2.0 V PENCIL HiTESTER 3246 ●Measurement system: average value rectification ●Display: Max.4199-count LCD ●Range switching: automatic or manual ●Ancillary functions: data hold function, auto power save function, battery life warning function, penlight, backlight LCD ●Sampling rate: 2.5 times/sec ●Overload protection: 600 Vrms (sin) or 3 × 106 VHz for all functions ●Applicable standards: Safety - EN61010, EMC - EN61326 ●Ambient temperature of use: 0 to 40˚C(32˚F to 104˚F), 80 % rh (no condensation) ●Storage temperature range: -20 to 60˚C (-4˚F to 140˚F), (no condensation) ●Power source: CR2032 battery × 1 (3V DC) ● Continuous operating time: approx. 150 hours (at DC V funtion), 30 hours (with penlight turned on for 10 seconds and off for 20 seconds per cycle and in DC V function) ●Dimensions, mass: 30 mm (1.18 in)W × 182 mm (7.17 in)H × 26.5 mm (1.04 in)D, 80 g (2.8 oz) n Option EXTERNAL SHUNT 9081 primary current: 10 A, secondary voltage: 100 mV HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1608-1610 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] Output is 100mV at 10A. Multiply the displayed value by 1/10 and interpret the resulting value as current. DISTRIBUTED BY Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : Room A-3206, Victory PlazaServices Center, No.103, Tiyuxi Road, Guangzhou, P.R.China POSTCODE:510620 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] All information correct as of May. 1, 2009. All specifications are subject to change without notice. 3246E9-95B-00P Printed in Japan