POSIROT ® – PRDS Output CANopen

POSIROT ® – PRDS
Output CANopen
Description
Interface CANOP
­­Magnetic angle sensor with CANopen interface according to CiA 406.
Communication profile
Device profile
Configuration services
Error Control
Node ID
PDO
PDO Modes
SDO
CAM
Certified
Transmission rates
Bus connection
Integrated bus terminating
resistor
Bus, galvanic isolated
Specifications
Excitation voltage
Excitation current
Resolution
Linearity
Measuring rate
Stability (temperature)
Repeatability
Operating temperature
Protection
Dielectric strength
EMC Automation
CANopen CiA 301 V 4.02, Slave
Encoder CiA 406 V 3.2
Layer Setting Service (LSS), CiA Draft Standard
305 (transmission rate, node id)
Node Guarding, Heartbeat, Emergency Message
Default: 127; programmable voa LSS or SDO
3 TxPDO, 0 RxPDO, static mapping
Event-/Time triggered, Remote-request, Sync
cyclic/acyclic
1 server, 0 client
8 cams
Yes
50 kBaud to 1 MBaud, default: 125 kBaud;
programmable via LSS or SDO
M12 connector, 5 pins
No
No
11 ... 36 V DC
Typ. 15/30 mA for 24/12 V, 100 mA max.
0.05° max.
1° (0.25° as option)
1 kHz (asynchronous)
±50 x 10-6 / °C f.s.
1 LSB
-40 ... +105 °C
Reverse polarity, short circuit
1 kV (V AC, 50 Hz, 1 min.)
EN 61326:2004, table A1
ASM GmbH
www.asm-sensor.com
MAN-PRDS-E-11
21
POSIROT ® – PRDS
Output CANopen
Setup
Before connecting to the CAN bus make sure that every node has a different node ID and a common bit rate. If necessary set node ID and bit rate by
the Layer-Setting-Service (LSS) as defined in Standard CiA DSP-305.
If LSS is not available node ID and bit rate can be changed by writing the
new values to objects 2000 and 2010 via Service Data Object (SDO). New
node ID and bit rate become effective not before ”SAVE” and resetting the
device.
After power up the slave will send a boot-up message and will be ready
for configuration and start of data exchange. On first power-up the default
parameters are effective.
Change parameters and operating mode of process data objects after
importing the EDS file by the master software. Changed parameters become effective immediately. Parameters will become non-volatile on writing
”SAVE” to object 1010-1.
Note: Setting of some parameters may have influence on the function of
other parameters, e.g. changing the resolution may also influence the cam
function.
Warning notice
• Changing the parameters can cause a sudden step of the ­instantaneous
value and can result in unexpected machine (re)actions!
22
•
Precautions to prevent danger for man or machine are necessary!
•
Execute parametrizing at standstill of the machine only!
MAN-PRDS-E-11
www.asm-sensor.com
ASM GmbH
POSIROT ® – PRDS
Output CANopen
Device profile
SAVE
LOAD
Manufacturer-specific
Node ID
Bitrate
User Offset
Filter
Angle encoder CiA406
Operating Parameters
Measuring Units per Rev.
Preset Value
Position Value
Cyclic Timer
Number of revolutions
Profile and SW Version
Serial Number
Cam function CiA406
Cam state register
Cam enable register
Cam polarity register
Cam 1-8 low limit
Cam 1-8 high limit
Cam 1-8 hysteresis
Index
1010-1
1011-1
Default
„save“
„load“
Value range
MSB...LSB 73h,61h,76h,65h
MSB...LSB 6Ch,6Fh,61h,64h
2000
2010
2100
2102
127
4
0
1
1...127
0...7 (s. table below)
-231 …231-1
1...255
6000-0
6001-0
6003-0
6004-0
6200-0
6502-0
6507-0
650B-0
0
16383
0
0...7
6300-1
6301-1
6302-1
6310-1...6317-1
6320-1...6327-1
6330-1...6337-1
0
0
0
0
0
0
100
1
Operating Parameters Bit Code
15
...
...
...
4
3
MSB
cs = 0
cs = 1
sfc = 0
sfc = 1
2
sfc
1
0
cs
LSB
Code sequence CW
Code sequence CCW
Scaling function disabled
Scaling function disabled
Bit rates
Index
Bit rate
0
1
2
3
4
5
6
7
1 MBit/s
800 kBit/s
500 kBit/s
250 kBit/s
125 kBit/s
reserved
50 kBit/s
20 kBit/s
ASM GmbH
www.asm-sensor.com
MAN-PRDS-E-11
23
POSIROT ® – PRDS
Output CANopen
Process data
CAM
­function
PDO
TxPDO-01
TxPDO-02
TxPDO-04
CAM active inactive Content
Position value (4 Byte)
Position value (4 Byte)
CAM Status (1 Byte)
Preselected transmission mode
Asynchronous 100 ms
Sync Mode
Change of State Mode
Hysteresis Hysteresis Lo-Limit Signal wiring /
connection
CAN bus wiring
Signal name
Hi-Limit Connector pin
Wire color
1
2
3
4
5
Braid
White
Brown
Blue
Black
Shield
Excitation +
GND
CAN-H
CAN-L
Connect the device by a T-connector to the CAN trunk line. Total length of
stubs should be minimized. Do not use single stub lines longer than 0.5 m.
­Connect terminating resistors 120 Ohm at both ends of the trunk line.
Terminating
resistor
Cable
T-piece
Device 1
24
View to sensor connector
MAN-PRDS-E-11
www.asm-sensor.com
Cable
T-piece
Device 2
Terminating
T-piece resistor
Device n
ASM GmbH