POSITILT® CANopen Output Specification

POSITILT®
CANopen Output Specification
Description
CANopen Interface
Inclination sensor with CANopen interface according to CiA 410.
Communication profile
Device profile
Configuration services
Error Control
Node ID
PDO
PDO Modes
SDO
Certified
Transmission rate
Bus connection
Integrated bus terminating
resistor
Bus, galvanic isolation
Specifications
Excitation voltage
Excitation current
Measuring rate
Stability (temperature)
Repeatability
Operating temperature
Protection
EMC
CANopen CiA 301 V 4.02, Slave
Inclinometer CiA 410 V 1.2
LSS, CiA Draft Standard 305 (transmission rate,
node ID)
Node Guarding, Heartbeat, Emergency Message
Adjustable via LSS or via object dictionary;
default: 127
1 TxPDO, 0 RxPDO, static mapping
Event-/Time triggered, Remote-request, Sync
cyclic/acyclic
1 Server, 0 Client
Yes
50 kBaud to 1 MBaud, adjustable via LSS or via
object dictionary, default: 125 kBaud
M12 connector, 5 pin
Configurable
No
8 ... 36 V DC
15/30 mA typical for 24/12 V, 100 mA max.
1 kHz standard
±100 x 10-6 / °C f.s.
1 LSB
-40 ... +85 °C
Reverse polarity, short circuit
EN61326-1:2006
ASM GmbH
www.asm-sensor.com
MAN-PT-E-10
13
POSITILT®
CANopen output - set up procedure
Setup
procedure
­ efore connecting to the CAN bus make sure that every node ID is used
B
once only and all nodes have the same baud rate. If necessary set node
IDs and transmission rate.
After power up the slave sends a boot-up message and is ready for
­configuration and start of data exchange. On the first power-up the default
parameters are effective.
After reading the EDS file by the control unit the parameters can be changed according to application requirements. Changed parameters become
effective immediately. Non-volatile storage of the parameters by write
­access „save“ on object 1010/1. Node ID and bit rate can be changed via
LSS (CANopen Layer Setting Services). Alternatively node ID and bitrate
can be configured via object dictionary. These settings become effective
not before „save“ and resetting the device.
Note: Setting of some parameters may have influence on the function of
other parameters, e.g. changing the resolution may also influence the cam
function. For further information refer to the device profile.
Warning notice
• Changing the parameters can cause a sudden step of the ­instantaneous
value and can result in unexpected machine (re)actions!
14
•
Precautions to prevent danger for man or machine are necessary!
•
Execute parametrizing at standstill of the machine only!
MAN-PT-E-10
www.asm-sensor.com
ASM GmbH
POSITILT®
CANopen output - set up procedure
Device profile
SAVE
LOAD
Manufacturer specific
Node-ID
Bitrate
Hysteresis send-on-change
Bus termination
Filter
Inclinometer CiA410
Resolution (in 0,001°)
Slope long16
inclination angle round x axis
Oper. parameters slope long16
1 or 2 axes
Slope long16 preset value
Slope lateral16
inclination angle round y axis
Oper. parameters slope lateral16
2nd axis
Slope lateral16 preset value
Index
1010-1
1011-1
Default
„save“
„load“
Value range
MSB...LSB 73h, 61h, 76h, 65h
MSB...LSB 6Ch, 6Fh, 61h, 64h
2000
2010
2040
2050
2102
127
4
10
0
16
1 ... 127
0...6 (s. table below)
6000
6010
100
10 ... 10000
6011
0
6012
6020
0
6021
0
6022
0
0 (off), 1 (on)
1...65535
Operating Parameters Bit Code
7
m
MSB
...
i = 0/1
s = 0/1
m = 0/1 Bit rates
2
1
s
0
i
LSB
Code sequence CW/CCW
Scaling function disabled/enabled
Operating mode: 1 axis x ±180°/2 axes x,y ±60°
Index
Bit rate
0
1
2
3
4
5
6
1 MBit/s
800 kBit/s
500 kBit/s
250 kBit/s
125 kBit/s
reserved
50 kBit/s
ASM GmbH
www.asm-sensor.com
MAN-PT-E-10
15
POSITILT®
CANopen output - set up procedure
Process data
Signal wiring /
connection
CAN bus
wiring
Preselected
transmission mode
PDO
Inclination 4 byte
TxPDO-01
LSBX MSBX LSBY MSBY Asynchronous 100 ms
Signal name
Wire color
Connector pin
Grey
White
Brown
Green
Yellow
1
2
3
4
5
Screen
Excitation +
GND
CAN-H
CAN-L
View to sensor connector
Connect the device by a T-connector to the CAN trunk line. Total length of
stubs should be minimized. Do not use single stub lines longer than 0.5 m.
­Connect terminating resistors 120 Ohm at both ends of the trunk line.
Terminating
resistor
Cable
T-piece
Device 1
Cable
T-piece
Device 2
Terminating
T-piece resistor *
Device n
* Only if device n has no
internal terminating resistor
16
MAN-PT-E-10
www.asm-sensor.com
ASM GmbH