AC Power Systems Nfinity High Availability Power Protection The Problem Is That You Depend On Your Network More Than Ever The digital lifeblood of many organizations - computers, servers, phones, datacom links-now resides on networks…outside of the traditional “glass house” protection. This may make companies more flexible and responsive, but it also makes them far more vulnerable to power problems, and the threat of catastrophic losses in sales, customers, pro ductivity…your business lifeblood. The Solution Is A UPS Designed Like Never Before Now for the first time, your can achieve the highest levels of UPS reliability in a system that is sized to protect network applications. The Liebert Nfinity UPS is designed for use with workstations, servers, networks, telecommunications equipment or other sensitive electronics. It provides continuous, high-quality AC power to your missioncritical systems, protecting them from any power aberrations due to blackouts, brownouts, surges or noise interference. The Nfinity power system is a scalable 4 to 16 kVA UPS, designed with N+x parallel redundancy to provide a fault-tolerant network of power protection formaximum systems availability. Its modular design makes Nfinity the most adapt able UPS on the market, offering easy upgrades and servicing. Scalability Is Just The Start Of The Value } Configure the system that’s right for you today and tomorrow you need shipped complete, ready for final connection } Everything Intelligence Means Maximum Performance } Power responsiveness ability to communicate } Self diagnosis } The Highest Levels Of Redundancy Mean Maximum Systems Availability } Redundancy at all the critical points of UPS operation without shutdown } Maintainability Liebert Puts It All Together In The Nfinity UPS System It looks and works like no UPS we’ve offered before. Nfinity’s unique frame design houses all of the modular system components. It contains bays to hold the power modules, battery modules and system control modules. The modules offer hotswap capability, making it easy to add capacity or replace modules. The Nfinity class of power protection offers a variety of advantages. The Right Size For Your Network Protection Plans Nfinity’s modular design was devised to provide easy scalability to users as their power demands grow. By simply installing additional power or battery modules, you can expand your current system, extend yourbackup runtime or add redundancy. Scalability Provides The Flexibility To expand Nfinity’s patent-pending frame design provides the user with the maximum adaptability that is demanded in today’s everchanging network environment. Because Nfinity is scalable for redundancy, power capacity or battery run time, you have greater flexibility in how you can use the system. Configurations can be cost-effectively upgraded without re-investing in a new system or installation. Longer Battery Run Time The system’s flexible frame design allows battery backup times to be customized to customer needs while maintaining a smaller footprint. To extend run times, just add battery modules. Nfinity also has a faster recharge time than similar units. Hot-Swappable Hot-swappable modules allow you to add or replace power, battery and control modules without shutting the load down or affecting power to it. In redundant mode, this means no downtime for repair. Nfinity’s hot-swappable modules also make it easy for the user to handle basic service. Cabinet Stands Small, Stays Small Nfinity’s compact, efficient design allows you to pack more power and battery capability into a much smaller sized unit, so it takes up less of your valuable floor space. Initial System 4 kVA Redundant Upgrade System Capacity 8 kVA Redundant Extend System Run Time 8 kVA Redundant Power Modules Power Modules Power Modules Blank Blank Batteries Batteries Batteries The system control module provides communications and control for the unit. The system utilizes independent 4 kVA power modules. Up to four power modules can be operating at one time. Each battery module is composed of ten individual 12-volt batteries encased in a plastic housing. Power and battery modules are housed in identical bays within the frame. Power modules must be contained in the top half of the frame, while battery modules can be utilized in any of the bays. This allows battery backup times to be configured to customer needs. Fault-Tolerant Dual Control Modules Fasieners Fault LED Status LED User interfce Module Lever System Control Module IntelliControl™ Module - The system control module works with the user interface to provide vital information about the condition of the power and battery modules. The use of a paired system control provides full systems functionality in the event of any single failure and ensures that operations and communications are always available. Communications Capability The Liebert Nfinity UPS incorporates extensive firmware designed to provide a comprehensive range of control and operating information, as well as communications capability. User Interface Control Panel The user interface module is the main source of communication between the Nfinity UPS and the user. It features an easy-toread LCD display and LED mimic diagram. The control panel informs the user of the status of the UPS, including the power and battery modules, and allows you to configure the system to fit specific needs or preferences. You can also review the event log and even receive instructions on replacing modules. Redundant Monitoring Options Dry contacts and a serial communications port are standard. The unit also includes four Intellislot™ ports for multiple user options including: } SNMP cards that allow the Nfinity to communicate with an Ethernet network. } MultiPort4 cards that enable up to four client computers to monitor UPS status. } Relay contact cards to provide contact closures or remote monitoring of alarm conditions. }The system also communicates to and monitors internal and extended battery cabinets. Flexible Power Modules Keep Your Business Online Intelligent Power Modules - provide protection against power outages, spikes, surges, noise, and sags. Designed in 4kVA “building blocks,” they utilize patent pending current sharing technology that ensures premium quality power. Nfinity power modules feature a power factor corrected (PFC) rectifier to create a sinusoidal input current waveform. This allows the system to use utility power more efficiently and reduces reflected distortion. A true on-line system, Nfinity provides continuous, regenerated sinewave output power. Nfinity is a 4 to 16 kVA UPS designed with N+x parallel redundancy to provide a fault tolerant network of power protection for maximum systems availability. Redundant Power Modules - parallel redundancy is achieved by adding extra powermodules that equally share the electrical load. Wider Input Voltage Window A wider, variable input voltage range minimizes transfer to battery to increase battery life. For lighter loads, low line transfer can range down to 110V. Generator Compatible Full time output voltage and frequency regulation is provided - a necessity for sensitive electronic equipment and a must for sites with back up generators. Highest Overload Capability Nfinity offers the highest overload capability of any system in its class - capable of sustaining 110% of the system’s rated load for an extended period of time. Power odule Battery Module Shipping serews Fastner Status LED Fault LED Cooling Fan Lever FRONT FRONT Under normal operation, the Status LED (green) will blink and the Fault LED (amber) will be off. Longer Runtimes For Maximum Availability IntelliBattery™ Module - Nfinity’s innovative battery module continuously monitors the battery’s voltage, current, and temperature to determine the state of its batteries and predict performance. Each module contains an intelligent battery sensing circuit that will take it off-line if a problem is detected, so as not to affect the pefor mance of other good battery modules in the system. Extended Battery Cabinets The Nfinity extended battery cabinet is available when extra run time is critical to your protected loads. This unit has 12 bays that accept up to 12 standard Nfinity intelligent battery modules, allowing you to add battery capacity as needs change. A built-in microprocessor in each battery module provides the intelligence and communication capability to allow the module to automatically remove itself from the critical DC bus if necessary. The extended battery cabinet reports and tracks individual module capacity, temperature and charge level, as well as other data and reports this information to the Nfinity system control. Nfinity Battery Run Times (min 8 Bay 1x1 Units 12 Bay 1x1 Units 12 Bay 3x1 Units Quantity of Battery Modules Load VA 20,000 19,500 19,000 18,500 18,000 17,500 17,000 16,500 16,000 15,500 15,000 14,500 14,000 13,500 13,000 12,500 12,000 11,500 11,000 10,500 10,000 9,500 9,000 8,500 8,000 7,500 7,000 6,500 6,000 5,500 5,000 4,500 4,000 3,500 3,000 2,500 2,000 Load Watt 14,000 13,650 13,300 12,950 12,600 12,250 11,900 11,550 11,200 10,850 10,500 10,150 9,800 9,450 9,100 8,750 8,400 8,050 7,700 7,350 7,000 6,650 6,300 5,950 5,600 5,250 4,900 4,550 4,200 3,850 3,500 3,150 2,800 2,450 2,100 1,750 1,400 1 7 9 11 14 18 2 7 8 8 9 11 12 14 15 19 23 28 33 42 3 7 7 7 8 9 10 11 12 13 14 16 17 19 21 23 25 31 37 44 52 65 4 7 7 7 8 8 8 9 10 12 12 12 14 15 15 16 17 19 21 23 24 24 23 28 37 43 51 60 71 88 5 7 7 7 8 8 8 9 9 9 10 11 12 13 13 13 14 16 17 17 18 19 21 22 23 25 28 30 32 36 39 42 47 55 65 76 89 112 6 9 9 9 11 12 12 13 13 13 13 14 15 16 16 17 18 20 21 21 23 24 26 28 29 31 34 36 40 43 47 52 57 66 79 93 109 136 7 12 12 13 13 14 14 15 15 17 17 18 19 20 20 21 22 24 25 26 28 29 30 33 35 37 40 43 47 51 56 61 67 79 93 109 128 160 8 19 20 21 22 23 24 25 26 28 29 30 32 34 36 38 40 43 47 50 55 60 66 72 78 91 107 126 147 183 Quantity of Extended Battery Cabinets 9 32 34 35 37 38 41 44 46 49 53 57 62 68 74 80 88 104 123 143 167 207 10 55 59 64 69 76 82 90 98 115 136 159 185 230 11 128 151 176 205 254 1 25 25 26 27 28 28 29 30 32 33 34 36 37 38 39 42 44 46 48 51 54 57 60 64 68 73 78 84 92 101 110 119 140 165 192 224 276 2 51 56 57 58 61 63 64 66 68 70 72 74 82 85 86 90 93 97 101 111 113 119 131 139 142 149 161 174 190 203 223 245 285 333 387 448 554 3 75 80 81 82 97 99 100 102 104 106 108 110 130 133 134 138 141 145 149 171 173 179 203 211 214 221 245 258 286 299 331 365 429 489 567 652 818 4 99 104 105 106 133 135 136 138 140 142 144 146 178 181 182 186 189 193 197 231 233 239 275 283 286 293 329 342 382 395 439 485 573 645 747 856 1,082 NOTE: In Red backup times for 8-Bay units, in Blue backup times for 3x1 (up to 20kVA) units. Backup times are in minutes and are based on resistive loading at an ambient temperature of 25°C under controlled conditions, for non-redundant configurations. Extended battery cabinets are fully loaded with 12 battery modules. Extended battery cabinets assume that the UPS frame is fitted with all available battery modules. Maximum Protection For Mission Critical Applications Nfinity is the first redundant UPS of its kind that ships as a complete, pre-configured system that is tested at the factory. Everything you need is included in a single package that’s ready to roll-in an hook up. User Interface Control Enable Switch (SW2) REPO Terminal Intellislot Commutations Port Port 1 Port 2 COM1 Port 3 Port 4 COM2 DB-9 Commutations Port Power Module Bays Battery Module Bays Output Power Terminal 220/240 Jumper (option transformateur seulement) Imput Power Terminal Imput Earth Terminal Manual Bypass Switch Imput Circuit Breaker(CB1) Intate Cooling Fans External Battery Connection Front Back 8 Bay Model Displayed - Also Available: 12 Bay Model, Extended Battery Cabinet Power Monitoring And Network Shutdown With Multilink Software MultiLinkTM is the perfect complement to the Liebert Nfinity UPS because it prevents unexpected server shutdowns, protects data and minimizes downtime. The software provides unattended, orderly shutdown for one computer or many, and is especially effective with large server farms. MultiLink has full event management and displays UPS instrumentation on screen. MultiLink is available for all popular operating systems and can be downloaded from the Liebert web at www.liebert.com. General & Environmental Rating Unit kVA 4 8 12 16 20 kW 2.8 5.6 8.4 11.2 14 Conducted and Radiated EMC Levels EN50091-2 Class A Compliant Safety Standards EN50091-1, EN 60950, CE, Low Voltage Directive Compliant Immunity Standards EN61000 - 4 - 2,3,4,5,6 Encombrements Unités 8 Bay Dimensions: Width mm Dimensions: Depth mm 711 Dimensions: Height mm 1016 12 Bay 508 1372 Environmental Operating Temperature (max) °C 0°- 40° Relative Humidity % de 0 à 95% sans condensation Maximum Operating Altitude m Nominal Heat Dissipation W Acoustic Noise Level Input Data dBA Nominal Input Voltage VAC 3000 311 @ 622 @ 933 @ 4kVA 8kVa 12kVA 1244 @16kVA 1265 @ 20kVA <62@ 1m 220/230/240 for 1x1 units 380/400/415 for 3x1 units (12 bay only) Power Factor cosw .98 for 1x1 units .80 for 3x1 units Input Frequency (nominal) Hz 50 Input Frequency Range Hz 40 - 70 Battery Module Number Of Lead Acid Batteries 10 Number Of Battery Cells 60 Battery Capacity Autonomy Time (full load) AH minutes 9 7 (with an equal number of Battery & Power modules in non-redundant configuration) Maximum Charge Current (full load) A 3 Nominal Voltage VDC 120 Recharge Time Output Data h Units 3 à 5 (à 90% capacity) Output Voltageie VAC 220/230/240 VAC Voltage Regulation % ±3 % Voltage Stability (100% step load) % ±7 % Recovery Time ms 96 ms Voltage distortion % < 3 % THD linear load Output Frequency Hz Efficiency at 100% load % Output Overload Capability % < 7 % THD non-linear load 50 Hz 91 % >100% - 110% for 10 min. 111% - 150% operates for 8 sec 151% - 200% operates for 0.25 sec >201% operates for 2 cycles for 1x1 units >100% - 110% operates indefinitely 111% - 150% operates for 8 sec 151% - 200% operates for 0.25 sec >201% operates for 2 cycles for 3x1 units NOTE: 3x1 units available in 12-Bay frames only. 16kVA 1x1 requires 12-Bay frame. 20kVA rating available for 3x1 models only. While every precaution has been taken to ensure accuracy and completeness in this brochure, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2009 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. Emerson Network Power, a business of Emerson (NYSE:EMR), is the global leader in enabling Business-Critical Continuity™. The company is the trusted source for custom, adaptive and ultra-reliable solutions that enable and protect its customers’ business-critical technology infrastructures. Backed by the largest global services organization in the industry, Emerson Network Power offers a full range of innovative power, precision cooling, connectivity and embedded products and services for computer, communications, healthcare and industrial systems. Key product brands within the Emerson Network Power family include Liebert, Knuerr, ASCO, Astec, Lorain. Emerson Network Power TM The global leader in enabling business-critical continuity. Emerson Network Power EMEA Via Leonardo da Vinci, 16/18 35028 - Piove di Sacco (PD) - Italy tel. +39 0499719111 fax +39 0495841257 [email protected] www.eu.emersonnetworkpower.com Embedded Computing AC Power Connectivity DC Power Embedded Power Monitoring Out Side Plant Power Switching & Controls Precision Cooling Rack & Integrated Cabinets Services Surge Protection Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co. BRO-NFIN-GB-XX General Features