Liebert® PSP - Emerson Network Power

AC Power Systems for
Business-Critical ContinuityTM
Liebert® PSP
Best-Value Power Protection for PCs and Peripherals
Liebert PSP is a full featured UPS that delivers
cost-effective power protection in a compact
package.
The UPS provides battery-backed outlets and a surge protectiononly outlet. The UPS battery offers four minutes of backup power at
full load - ample time to shut down protected equipment if an outage occurs.
Shutdown software and a USB cable are also included, to allow
remote alerts and automated graceful shutdown of the connected
equipment.
Liebert PSP UPS Supports Your Sensitive
Electronics With These Standard Features:
Flexibility
I
Three battery-backed UPS outlets, and one surge
protection-only outlet differentiated by color
I
USB port, MultiLink Software shutdown software,
and USB cable
I
User replaceable batteries
Higher Availability
I
Up to four minutes of battery backup time at full load.
Protects against lightning, spikes and surges
I
Full sequenced battery testing to ensure batteries
are available when needed
I
Advance early warning of UPS shutdown
I
RJ-45 port for data line surge protection
Lowest Total Cost Of Ownership
I
Two-Year replacement warranty
I
Optional one year warranty extension
The Liebert PSP Is Ideally Suited For:
I
Professional workstations
I
Small routers and bridges
I
Point-of-sale terminals
I
Other sensitive electronics
Liebert® PSP Specifications
Locations
Model Number
PSP500MT3-230U
Capacity VA/W
500 / 300
PSP650MT3-230U
650 / 390
Net Weight: kg
3.9
Shipping Weight: kg
4.8
Dimensions: W x D x H, mm
87 x 215 x 251
On-Line Mains Voltage
[email protected]
160-287VAC
On-Line Frequency
Via Fornace, 30
40023 Castel Guelfo (BO) Italy
Tel: +39 0542 632 111
Fax: +39 0542 632 120
[email protected]
50/60Hz ±5Hz
Output Voltage (Mains Normal)
Typical 160-287VAC
Output Voltage (Battery Operation)
230VAC ±5%
On-Battery Wave Form
Stepped Sinewave
Battery Type - VDC x Ah - Quantity
12V x 7.2Ah x 1
Typical Recharge Time
6-8 hours to 90%
Audible and Visual
United States
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
Tel: +1 614 8880246
Audible alarm / LED
Backup Sockets
IEC 320 C13 (3)
Surge Sockets
IEC 320 C13 (1)
Operating Temperature, °C
Asia
7/F, Dah Sing Financial Centre
108 Gloucester Road, Wanchai
Hong Kong
Tel: +852 2572220
Fax: +852 28029250
0 to 40
Storage Temperature, °C
-15 to 40
Operating / Storage Relative Humidity
0%-90%, non-condensing
EMI Classification
Emerson Network Power
Via Leonardo Da Vinci 16/18
Zona Industriale Tognana
35028 Piove di Sacco (PD) Italy
Tel: +39 049 9719 111
Fax: +39 049 5841 257
Class B
Agency
Safety
IEC/EN/AS 62040-1-1
EMC
EN 62040-2:2005 Class B
IEC 61000-4-2 Electrostatic discharge
IEC 61000-4-3 Radiated E-RFI fields
IEC 61000-4-4 Fast E transients
IEC 61000-4-5 Surges/Lightning
IEC 61000-4-6 Conducted RFI
Transportation
ISTA Procedure 1A Certification
Warranty
2 years standard (+ 1 year warranty extension available)
Packaging
User Manual on CD, Software CD, USB cable, Safety Instruction Sheet,
Environment protection sheet
Load Autonomy
Load (watts)
50
100
150
200
250
300
350
PSP500MT3-230U
PSP650MT3-230U
55
18
11
8
5
3
0
56
18
12
8
5
4
3
Note: All run times are in minutes, assume fully charged batteries and are typical at 25°C (77°F) with resistive loads.
Tech Support
Always On! Our Commitment to your daily
Business, provided by our World Wide multi
language Tech Support.
Toll-free 00-80011554499
Toll +39 02 98250222
[email protected]
While every precaution has been taken to ensure
the accuracy and completeness of this literature,
Liebert Corporation assumes no responsibility and
disclaims all liability for damages resulting fromuse
of this information or for any errors or omissions.
©2010 Liebert Corporation
All rights reserved throughout the world.
Specifications subject to change without notice.
PSP00-FLY-EN-0709-01
MKA4L0UKPSP Rev.1-07/2009
Emerson Network PowerTM
The global leader in enabling
Business-Critical Continuity™.
RJ-45 jacks (2)
Network
Protection
AC Power
Connectivity
USB interface
Resettable
Circuit Breaker
DC Power
Embedded Computing
Embedded Power
Infrastructure Management & Monitoring
Input plug
IEC-320-C14
Outside Plant
Power Switching & Controls
Surge - only
receptacle
(1) IEC-320-C13
Battery Backup
receptacles
(3) IEC-320-C13
Back view
Communications/Shutdown Software:
Windows built-in power management functions provide monitoring of UPS status
and manage the automatic orderly shutdown of the computer if a power outage ever
exceeds the battery capacity of the UPS. Liebert Multilink shutdown and monitoring
software is also provided.
Precision Cooling
Racks & Integrated Cabinets
Services
Surge Protection
Emerson Network Power.com
Business-Critical Continuity, Emerson Network
Power and the Emerson Network Power logo
are trademarks and service marks of Emerson
Electric Co. ©2010 Emerson Electric Co.