Liebert NXC from 10 to 40 kVA

AC Power for
Business-Critical Continuity™
Liebert NXC from 10 to 40 kVA
®
Emerson Network Power, a division of Emerson, is a global company that combines technology
with design to supply innovative solutions for the benefit of its customers.
Emerson Network Power is the leader in the “business-critical continuity” field, thanks to the
company’s products and services.
Emerson Network Power’s broad technology base and global expertise support a full spectrum of
enterprise-wide solutions for today’s vital business needs.
Regardless of your size,
you can’t afford for your
critical business systems
to go down and you can’t
waste time recovering your
IT infrastructure after a
disruption.
Leave that to us, the experts
in business-critical continuity:
from grid to chip, from the
biggest to the smallest data
centers, we are ready to serve
your needs with the solutions
we have developed.
2
More standardization, so you
don’t need further budget
allocations to install it.
More simplification so you
don’t need to be a specialist
to get the best for your
business.
More support, so while you
are enjoying doing business,
we are protecting you.
3
Liebert® NXC From 10-40 kVA
Features and Performances
•0.9 output power factor
•Double conversion efficiency
up to 95%
•Eco mode efficiency up to
98%
•Input current
total harmonic distortion
correction (THDi) < 4%
•Battery charger up to 6 kW
•Integrated manual bypass
•Integrated input and output
breakers/switches
•Integrated parallel load
bus and synchronization
port (LBS)
Continuous Reliability
The Liebert® NXC 10 - 40
kVA range offers reliable and
flexible secure power in a fully
integrated package solution. Its
highly efficient transformer-free
double conversion technology
delivers installation and running
cost savings. With a rated
output power factor of 0.9,
Liebert® NXC is also able to
provide 12.5% greater active
power than a traditionally rated
0.8 power factor UPS.
Liebert® NXC achieves up
to 95% efficiency in double
conversion mode and up to
98% in Eco mode, thus ensuring
effective load protection,
while reducing the total
cost of ownership (TCO) and
environmental impact.
Liebert® NXC’s combination
of performance features,
impressive integrated
autonomy and compact
footprint make it ideal for
guaranteeing clean, continuous
power for a wide range of
applications from IT and
manufacturing to retail and
transport.
Its low THDi (< 4%) and active
input power factor correction
ensure that the current
absorbed from the upstream
distribution network is near
equal to its nominal output
current, hence eliminating the
need for oversizing gensets and
other equipment.
96%
95%
94%
93%
92%
91%
90%
89%
88%
20%
30%
40%
50%
60%
Load
Liebert ® NXC efficiency curve
4
70%
80%
90%
100%
Flexibility
To ensure superior protection
for critical loads, the Liebert®
NXC range has been designed
to optimize specific rating
requirements, thus enhancing
flexibility and installation space
needs.
Liebert® NXC’s flexibility is
further enhanced through:
•Single and three phase
output configuration
•Integrated parallel and dual
bus control
•Common or distributed
battery bank
•Multiple internal battery
configurations for flexible
internal back up time
management.
Output Configuration
Liebert® NXC models up to 20
kVA can be configured on-site
to deliver three (3/3) or single
(3/1) phase output giving it the
flexibility to adapt to changes in
installation environments.
Full Galvanic Isolation
Liebert® NXC offers integrated
full galvanic isolation, meaning
that an isolation transformer
may be housed inside the
UPS cabinet. This greatly
reduces the system footprint,
thus providing space saving
advantages. The transformer
may be connected to the input
or to the output of the UPS,
providing:
•Full galvanic isolation for
medical and other critical
applications
•Installation with two
independent input sources
(with different neutrals)
•Installation in distribution
without neutral.
UPS with fully
integrated
battery
1240
860
500
Integrated Autonomy
Liebert® NXC provides an
excellent integrated autonomy
which results in back up times
of up to one hour.
Its spacious internal
architecture is able to house
up to four battery strings,
further optimizing integrated
autonomy and delivering the
added advantage of virtually
eliminating the need for an
external battery cabinet.
This furthermore reduces
installation costs and minimizes
the demand on physical space.
In addition, Liebert® NXC’s
powerful battery charger (up to
6 kW) ensures rapid recharge,
increasing its ability to manage
longer back up times.
UPS with
integrated
isolation
transformer
and battery
1240
860
500
5
In The Field
Trellis™ Platform
Liebert® NXC can be integrated
into Emerson Network Power’s
Trellis™ platform. A real-time
infrastructure optimization
platform that enables the unified
management of data centre IT
and facilities infrastructure.
The Trellis™ platform software
can manage capacity, track
inventory, plan changes, visualize
configurations, analyze and
calculate energy usage, and
optimize cooling and power
equipment as well as enable for
virtualization.
The Trellis™ platform monitors
the data center, providing a
thorough understanding of
system dependencies to help IT
and facilities organizations keep
the data center running at peak
performance. This unified and
complete solution, delivers the
power to see the real situation in
your data center, make the right
decision and take action with
confidence.
Parallel and Dual Bus Ready
Liebert® NXC can be connected
with up to four units in parallel.
A single unit can be upgraded
to parallel operation via easy
to modify software settings,
allowing the system to be
customized for the requested
configuration.
The Loop BUS connection
used in paralleling the system
Furthermore, the output
of two single or parallel
Liebert® NXC units can be
synchronized to deploy a dual
bus feed, achieving Tier IV level
reliability.
Automatic AC Bypass
AC
Normal
AC
Normal
AC
Normal
Load
Liebert ® NXC - Parallel configuration
6
delivers ultimate reliability and
eliminates the possibility of a
single point of failure, ensuring
perfect load sharing and fast
detection of any variation in the
system status.
AC
Normal
Communication
Liebert® NXC features a multi-lingual LCD user interface allowing
close control and monitoring of system status and performance.
The UPS offers the following communication features:
• Voltage-free contact ports
• USB interface
• Optocoupler based interfaces
• Intellislot for SNMP, Modbus or Relay communication.
These communication capabilities make Liebert® NXC compatible
with any building management system.
Software Connectivity
Liebert Multilink™ software
prevents unexpected server
shutdowns and minimizes
downtime warning of pending
power losses and initiating safe
shutdown of operating systems if
required.
Liebert Nform™ network
communications system
enables customers to leverage
the distributed monitoring
capabilities of network
connected equipment, providing
centralized management of
distributed systems.
Serviceability
The architecture of the Liebert®
NXC is designed to optimize
installation and simplify service
with its easily removable power
assembly. This architecture
considerably minimizes the time
needed for repairs and optimizes
serviceability.
Liebert® NXC also comes
equipped with casters to
facilitate ease of movement and
relocation.
Liebert ® NXC - 10 - 20 kVA
Liebert ® NXC - 30 - 40 kVA
Connectivity cards
7
Servicing Critical Infrastructure
Proactive equipment maintenance reduces downtime and extends equipment life which in turn maximizes
return on investment and increases system availability. Emerson Network Power supports entire critical
infrastructures with an extensive service offering, guaranteeing network availability and total peace of mind
24/7.
Our approach to servicing critical infrastructure covers all aspects of availability and performance, from
single units to entire mission critical systems, providing customers with tailored services to meet their
individual business needs and further guaranteeing Business-Critical Continuity™.
Emerson Network Power’s service program is designed to ensure that your critical power protection
system is maintained in an optimum state of readiness at all times.
The LIFE™.net remote monitoring and diagnostic service provides early warning of UPS conditions and out of
tolerances. This allows effective proactive maintenance, fast incident response and remote trouble shooting,
giving customers complete security and peace of mind.
Maximize Availability
Pre-Emptive Maintenance
Regular preventive maintenance increases uptime. Emerson Network Power’s LIFE™.net
provides early warning of operating anomalies allowing real-time diagnosis and swift
identification and resolution.
Minimize Downtime
Immediate Identification of Problems
Should an emergency condition arise, an engineer in the 24/7 manned LIFE™.net
service center carries out an immediate fault analysis and instigates appropriate
corrective action.
Reduce Operating Costs
Superior Asset Management
Through comprehensive data collection and analysis, LIFE™.net’s detailed reporting
system provides valuable information on power and equipment trends, over any selected
period of time.
8
Liebert® NXC
Specifications
Technical Characteristics (3/3 and 3/1 configurations)
10 kVA
Ratings (kVA)
15 kVA
20 kVA
30 kVA
40 kVA
Input
380/400/415
Nominal input voltage (V)
305V to 477
Input voltage range without battery discharge (V)
50/60
Nominal frequency (Hz)
40 to 70
Input frequency range (Hz)
0.99
Input power factor (kW/kVA)
<4
Current THD at full linear load (THDI%)
selectable from +20 to -40
Bypass voltage tolerance (%)
±20 ( ±10 selectable )
Bypass frequency tolerance (%)
Battery
Max: 240; Min: 180
Number battery cells per string
Max: 240; Min: 192
-3.0 (selectable 0 to -5.0 around 25°C or 20°C or inhibit)
Voltage temperature compensation (mV/°C/Cell)
Battery charger max. power (kW)
4.5
6
380/400/415 (three-phase)
or 220/230/240 (single-phase)
380/400/415 (three-phase)
Output
Nominal output voltage (V)
50/60
Nominal output frequency (Hz)
9
Nominal active power (kW)
13.5
27
36
2
THDv with 100% linear load (%)
105% for 60 min; 125% for 5 min; 150% for 1 min; >150% for 200ms
Inverter overload capacity
Double conversion efficiency
18
100%
94.4%
94.5%
94.2%
94.7%
94.4%
75%
94.0%
94.4%
94.5%
94.8%
94.7%
50%
93.5%
94.0%
94.4%
94.6%
94.8%
25%
90.5%
92.9%
93.5%
91.7%
93.6%
98.0%
Eco mode efficiency (%)
Dimensions and weight
500 x 860 x 1240
600 x 850 x 1600
Weight (excluding battery) kg
115/145
210/245
Weight (including 32 batteries) kg
215/245
600/635
Dimensions (W x D x H) mm
General
Noise at 1 m (dBA)
Protection level IEC (60529)
≤56
≤56
≤58
≤58
IP20
General and safety requirements for UPS
EN/IEC/AS 62040-1
EMC requirements for UPS
EN/IEC/AS 62040-2
UPS classification according to CEI EN 6240-3
≤56
VFI-SS-111
9
Emerson Network Power Business-Critical Continuity Expert
TM
Today’s successful businesses depend on adaptable technologies to help them respond quickly
to market demands. Your data center must be built on a support infrastructure designed to
match the power and cooling needs of rapidly changing IT initiatives such as virtualization and
consolidation. Each IT change, move or addition will affect the entire support infrastructure
so you need products and support that ensure your IT systems will operate reliably in these
environments.
Get more on line: www.EmersonNetworkPower.eu
10
More than 35,000 organizations in 70 countries depend
on our Business - Critical Continuity TM Promise:
your IT infrastructure stays up to support your Business!
11
Ensuring The High Availability
Of Mission-Critical Data And Applications.
About Emerson Network Power
Emerson Network Power, a business of Emerson (NYSE:EMR),
delivers software, hardware and services that maximize availability,
capacity and efficiency for data centers, healthcare and industrial
facilities. A trusted industry leader in smart infrastructure
technologies, Emerson Network Power provides innovative data
center infrastructure management solutions that bridge the gap
between IT and facility management and deliver efficiency and
uncompromised availability regardless of capacity demands. Our
solutions are supported globally by local Emerson Network Power
service technicians. Learn more about Emerson Network Power
products and services at
www.EmersonNetworkPower.eu
Locations
Emerson Network Power
Via Leonardo Da Vinci 16/18
Zona Industriale Tognana
35028 Piove di Sacco (PD) Italy
Tel: +39 049 9719 111
Fax: +39 049 5841 257
Via Fornace, 30
40023 Castel Guelfo (BO) Italy
Tel: +39 0542 632 111
Fax: +39 0542 632 120
[email protected]
United States
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
Tel: +1 614 8880246
Asia
7/F, Dah Sing Financial Centre
108 Gloucester Road,Wanchai
Hong Kong
Tel: +852 2572220
Fax: +852 28029250
While every precaution has been taken to ensure accuracy and completeness
of this literature, Emerson Network Power and/or its affiliates makes no
representations or warranty about the accuracy, reliability, completeness, or
timeliness of the materials and disclaims any and all liability for damages resulting
from use of this information or for any errors or omissions.
©2013 Emerson Network Power. All rights reserved.
Specifications subject to change without notice.
MKA4L0UKNXC Rev. 2-02/2013
Emerson Network Power
The global leader in enabling Business-Critical Continuity™
AC Power
Embedded Computing
Outside Plant
Racks & Integrated Cabinets
Connectivity
Embedded Power
Infrastructure Management & Monitoring
Power Switching & Controls
Services
Precision Cooling
Surge Protection
DC Power
Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2013 Emerson Electric Co.