LIQUI-TECT® 410
Specifications
• Glycol, Chilled
Water Cooling
• Humidification
Feed Water Piping
• Condensate Pumps
and Drains
• Unit and Ceiling
Auxiliary Drip Pans
• Overhead Piping
Troughs
• Large-Scale Network Control
Centers
• Data Centers
• Server Rooms - Closets
• Unattended Remote Shelters
• Mechanical Equipment Rooms
• Sensitive Areas With
Overhead Piping
• Industrial Process Control
Rooms
Placement on Subfloor
5.85"
(148.5mm)
Form-C relay
outputs &
power wiring
connection
FRONT VIEW
4.46"
(113.2mm)
2.25"
(57.2mm)
Adjustable
probe height
0.0–0.5"
(0.0–12.7mm)
Shipping weight: 2 Ibs (0.9 kg)
Mounting holes: #8 screws
6.35"
(161.2mm)
Wiring Interconnections
Red Wires
Orange Wires
Yellow Wires
24 V, AC/DC
Alarm Contact Rating Alarm Contact Rating
@0.10A, 50-60Hz, DC
24 VAC @ 3A
24 VAC @ 3A
Class 2 Circuit Only Class 2 Circuit Only Class 2 Circuit Only
Power
Under Cooling Support Equipment
2-NC
2-COM
Locations
SIDE VIEW
TOP VIEW
2-NO
Applications
Dimensions-Top, Front & Side Views
1-NC
1-COM
The Liqui-tect 410
(LT410) provides a
single-point detection
of leaks. The point
detection sensor has
two gold-plated
sensing probes to
prevent corrosion
resistance and to
provide accurate
readings. The LT410
constantly monitors
points for leaks,
internal faults and power failures and warns of any
abnormal conditions. Mounting brackets allow for
sensor height adjustment and leveling.
The LT410 is the ideal solution for sensing leaks under
a raised computer floor or air conditioning drip pans.
Two independent outputs provide added flexibility
with the capacity to signal both a local alarm panel
and a remote building management system or external
equipment, such as motorized water shut-off valves.
The LT410 is also ideally suited for the following:
1-NO
Description
Liqui-tect 410 Sensor
Power requirements
24 VAC 100 mA, 50/60 Hz, 3 VA (max.)
Dimensions
6.35" x 2.25" x 4.46"
WxDxH
(161.2 mm x 57.2 mm x 113.2 mm)
Weight (assembled)
2.0 lbs (0.9 kg)
Metal enclosure
NEMA 1, IP 30
Environmental Conditions
Operating temperature 50°F to 104°F (10°C to 40°C)
10% to 95% relative humidity
Operating humidity
(non-condensing)
Operating altitude
0 to 10,000 ft (0 to 3,048 m)
Output Relays
Contact rating
2 Form-C; 3 A rating at 24 VAC
Agency Listings
UL
UL916
C-UL
C22.2, No. 205-M1983
CE
Yes
FCC Compliance
47 CFR, Part 15
Power
Point Leak Detection Sensor
To a Liebert
environmental
unit and
an optional*
monitoring
panel
Gold-plated
probes
To external
power
supply or
directly
from
unit
LT410
Leak detection
zone (directly
beneath unit)
Ordering Information
Product
Number
* Output connections to external alarm monitoring panels
such as the Liebert contact closure alarm panels
Product Specification Sheet
Height adjustable
0-0.5" (0-12.7mm)
LT410
page 1
Quantity
Description
Point Leak Detection Sensor
11/02 (Rev. 0)
Power Wiring
Wiring to Auxiliary Alarm Panels
The LT410 is rated for 24 VAC, 50/60 Hz and
0.10 amp.
The LT410 has two Form-C dry contact alarm output contacts: orange wires (1) and yellow wires (2).
Each contact is rated for 24 VAC at 3 amp.
Figure 1 24V from Liebert environmental units to LT410
Figure 3 LT410 to Liebert environmental units
Liebert
Deluxe Sys/3,
Liebert
Deluxe
System/3,
Challenger, Himod
or
Challenger,
Himod
or
MM2 (8 Ton)
Mini-Mate2 (8 ton)
LT410
TB1
TB1
RedTB1
wires
LT460 to Liebert Environmental Unit
LT460
LT410
LT460
T5T5
(24V)
(24V)
TB1-1
Red
(Ground)
G5G5(Ground)
TB1-2
Red
Liebert MM2 (1 to 5 Ton)
24
24(24V)
(24V)
51
51,
Orange
TB2wires
to LT460
TB1
T5 (24V)
T5 (24V)
connection
on main
controller
board of
Liebert unit
LT460
LT460
TB1
TB1
From 24V
transformer
(Ground)
TB1-1
TB1-1
TB1-2
TB1-2
TB2-2
(C)
1-COM
TB1-1
TB1-1(24V)
(24V)
TB2-1
1-NO(N.O.)
TB1-2
TB1-2
4V transformer of
(24V)
here are no
ated terminalFrom 24V
(Ground)
tions) transformer*
or TB1-3
OR
Figure 4 LT410 to Liebert contact monitor panel
LT460
LT410
Yellow
wires
TB2
TB2-3
2-NC(N.C.)
Liebert
Mini-Mate2
Liebert MM2
(1 to 5 Ton)
(1 to 5 ton)
Environmental
Env.
Unit
unit
TB2-3
1-NC(N.C.)
TB1-2
Location of
55 or 56
Liebert Mini-Mate2
Liebert MM2 (1 to 5 Ton)
(1 to 5 ton)
LT460
LT410
TB1-1
Transformer
G5
TB2-2
(C)
1-COM
TB2-1
1-NO(N.O.)
TB1
Environmental Unit to LT460
Liebert Deluxe Sys/3,
24V fromHimod
Transformer
Challenger,
or
MM2 (8 Ton)
Environmental
Env.
Unit
unit
TB2-3
1-NC(N.C.)
LT460
Power Wiring
4V transformer of
(24V)
here are no
ated terminal
24V(Ground)
from Liebert
tions)
Orange
TB2wires
LiebertLiebert
Deluxe
System/3,
Deluxe Sys/3,
Challenger, Himod
or
Challenger,
Himod
or
MM2 (8 Ton)
Mini-Mate2 (8 ton)
LT410
LT460
(C)
TB2-2
2-COM
RedTB1
wires
TB2-1
2-NO(N.O.)
TB1-1
Red
Contactmonitor
Liebert Liebert
contact
Monitor Panel
panel
Alarm
panel
Alarm Panel
Input
Input
Contact
contact
(N.O.)
(N.O.)
TB1-2
Red
* Requires a 24V external transformer (there are
no 24V
designated
terminal to
connections
on the unit)
from Transformer
LT460
Transformer
LT460
Figure 2 24V
24V
from transformer to LT410
from Transformer to LT460
Transformer
Transformer
LT410
LT460
RedTB1
wires
From 24V
From
24V
transformer
transformer
Product Specification Sheet
Red
TB1-1
TB1-2
Red
page 2