LIEBERT INTELLISLOT® 485 CARD W ITH ADAPTER Product Specification/Installation Sheet Description The Liebert IntelliSlot 485 Card with Adapter provides Modbus connectivity for your Emerson Network Power equipment. Operating status is monitored and alarms are communicated via the RS-485 using the Modbus protocol. Compatibility With Other Emerson Network Power Products Precision Cooling Unit (Controller*) * Controller Codes • Liebert Challenger™ 3000 (L00, L15, LSM, LAM) • Liebert DataMate™ (L0B) • Liebert Deluxe System/3™ (L10, L15, LSM, LAM) • Liebert Himod™ (LAM) • Liebert Industrial Cooling Series™ (L10, LSM, LAM) • Liebert Mini-Mate™ (L0B) • Liebert Mini-Mate2™ (MM2) • Liebert Mini-Mate2 8 Ton (L8T) • Hiross™ Microface IGMnet • PEC/Atlas™ (CEMS100/LECS15) L00: Level 00 L0B: Level 0B L10: Level 10 L15: Level 15 LSM: Standard Microprocessor LAM: Advanced Microprocessor Large UPS • • • • Liebert Npower™ Liebert Series 300™ Liebert Series 600™/610™ (Single Module) Liebert Series 610 System Control Cabinet (Multi-Module) • Hiross 7200 (EMEA) • Hiross HiPulse™ (EMEA) Power Management • • • • Liebert Datawave® Liebert FPC™ Liebert Precision Power Center™ Liebert Static Transfer Switches: STS™, STS2-3 pole, STS2/PDU Overall and Mounting Dimensions 0.6" (15.3mm) 7" (177.8mm) 2.8" (71.1mm) 3.4" (86.4mm) 0.8" (20.3mm) Six holes, each 0.156" diameter 2.4" (61mm) 4" (101.6mm) 0.4" (10.2mm) 0.2" (5mm) 3.2" (81.3mm) 1 Customer Wiring Input power (input to TB3) Pin 1(+) Pin 2(-) Pin 3 (NC) Modbus output for BMS (output from TB2) DTE serial port for configuration (requires null-modem connection) TB1: Pin 1 (+), Pin 2 (-) TB2: Pin 1 (+), Pin 2 (-) IGMnet or Liebert SiteScan® Comms from unit (input to TB1 or P1) Refer to user manual for details Specifications Power Requirements AC Inputs 18 - 24 VAC; 50/60 Hz DC Inputs 12 - 36VDC Power Consumption 6VA maximum Dimensions - W x D x H: in. (mm) Weight 7 x 4 x 1.5 (178 x 102 x 38) Net - oz. (kg) 7 (0.2) Shipping - lb. (kg) 1.3 (0.6) Ambient Operating Environment, °F (°C) 32 to 104 (0 to 40); 10% to 90% RH (non-condensing) Ambient Storage Temperature, °F (°C) -4 to 140 (-20 to 60) Protection SELV Isolated User Connections, Watchdog Timer Circuitry Communication Ports Service Terminal (RS-232) DB9F, DTE Unit Input Communications TB1, 2-Position Terminal Block P1, 20-PIN Vertical Header with Ejection Latches (for some UPS models) Modbus (RS-485) TB2, 2-Position Terminal Block Wiring Specifications Connection Supported Wire Types Maximum Wire Length TB1 (RS-422) 18-22 AWG Stranded & Shielded; 18 AWG* recommended Non Plenum - Belden 9461; Plenum - Belden 88761 1000 ft. (300m) TB2 (RS-485) 18-22 AWG Stranded & Shielded; 18 AWG* recommended Non Plenum - Belden 9461; Plenum - Belden 88761 3000 ft. (915m) TB3 (Power Input) 18-22 AWG Stranded & Shielded; 18 AWG* recommended Non Plenum - Belden 8770; Plenum - Belden 88770 20 ft. (6m) DB9F Connector DTE Null Modem Cable 50 ft. (15m) Liebert Corporation 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Telephone: 1-800-877-9222 Facsimile: 1-614-841-6022 www.liebert.com © 2007 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-29106_REV02_10-07 2