Monitoring For Business-Critical Continuity™ Liebert IntelliSlot® Web Cards Firmware Upgrade Manual Liebert IntelliSlot Web Card, Liebert IntelliSlot Web Card-LB, Liebert IntelliSlot Web Card-LBDS, Liebert IntelliSlot Web Card NXL™, Liebert IntelliSlot Web Card-L, Liebert IntelliSlot Web/485 Card-ADPT TABLE OF CONTENTS 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Estimated Time to Download the Firmware Upgrade File . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 CONNECT TO THE CARD - TERMINAL EMULATION, TELNET OR WEB INTERFACE . . . . . . . . . .2 2.1 Open the Terminal Emulation Interface - Serial Connection . . . . . . . . . . . . . . . . . . . . . . . . . 2 2.2 Open the Terminal Emulation Interface - TCP/IP Connection . . . . . . . . . . . . . . . . . . . . . . . . 2 2.3 Open the Telnet Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.4 Open the Web Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3.0 PREPARING TO UPDATE LIEBERT INTELLISLOT FIRMWARE. . . . . . . . . . . . . . . . . . . . . . . . . .4 3.1 Requirements to Update the Liebert IntelliSlot Card’s Firmware . . . . . . . . . . . . . . . . . . . . . 4 3.2 Determine the Liebert IntelliSlot Card Type and Firmware Version . . . . . . . . . . . . . . . . . . . 4 3.3 Download the Firmware Upgrade File to the Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3.4 Choose a Method to Install the Firmware Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 4.0 UPDATING THE FIRMWARE - HTTP (WEB) METHOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 4.1 Install the Firmware Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 5.0 UPDATING THE FIRMWARE - TFTP (HYPERTERMINAL, TELNET, WEB) METHOD . . . . . . . . . .7 5.1 TFTP Method - Terminal Emulation / Telnet Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 5.2 TFTP Method - Web Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 6.0 UPDATING THE FIRMWARE - XMODEM (SERIAL) METHOD . . . . . . . . . . . . . . . . . . . . . . . . . . 11 FIGURES Figure 1 Null connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 TABLES Table 1 Table 2 Table 3 Table 4 Table 5 Overview of the upgrade process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Estimated Time for downloads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Communication settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firmware update settings - TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firmware update settings - Web . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i 1 1 2 7 9 ii 1.0 INTRODUCTION Liebert’s IntelliSlot® cards may be updated to take advantage of the latest release of the firmware with enhanced features, compatibility with new units or service patches. Upgraded firmware may be downloaded with a browser, such as Internet Explorer. Emerson maintains firmware upgrades on its Web site, www.liebert.com/downloads. Emerson manufactures various types of network cards for Liebert products. Before beginning any upgrade, determine the type of Liebert IntelliSlot card to be upgraded. This identifying information—the type of card and firmware version currently installed—may be found in the documentation shipped with the card or by reading the card’s support information through a terminal emulation, Telnet or Web interface, as described in 3.2 - Determine the Liebert IntelliSlot Card Type and Firmware Version. NOTE Emerson recommends that users read all the instructions prior to attempting a firmware upgrade. 1.1 Overview The firmware upgrade involves these steps: Table 1 Overview of the upgrade process Step For details, see: 1. Decide which interface to use to connect to the Liebert IntelliSlot card 2.0 - Connect to the Card - Terminal Emulation, Telnet or Web Interface 2. Prepare for the upgrade • Make sure you have everything needed to perform the upgrade 3.1 - Requirements to Update the Liebert IntelliSlot Card’s Firmware • Check the type of card and firmware version currently installed 3.2 - Determine the Liebert IntelliSlot Card Type and Firmware Version • Download the upgrade file from the Liebert Web site 3.3 - Download the Firmware Upgrade File to the Computer • Decide which method to use for the upgrade 3.4 - Choose a Method to Install the Firmware Upgrade 3. Follow the step-by-step instructions to upgrade the firmware with the chosen method: 1.2 • HTTP (Web) Method 4.0 - Updating the Firmware - HTTP (Web) Method • TFTP (HyperTerminal, Telnet, Web) Method 5.0 - Updating the Firmware - TFTP (HyperTerminal, Telnet, Web) Method • Xmodem (Serial) Method 6.0 - Updating the Firmware - Xmodem (Serial) Method Estimated Time to Download the Firmware Upgrade File The amount of time required to download the firmware upgrade file depends on the upgrade method used. Refer to Table 2 for estimated times for each method. Table 2 Estimated Time for downloads Upgrade Method Expected Speed HTTP (Web) Method (.bin file) 6-7 minutes (subject to network traffic) TFTP (HyperTerminal, Telnet, Web) Method (.bin file) 5-6 minutes (subject to network traffic) Xmodem (Serial) Method Xmodem 1K 115,200 bps 1st file 2 minutes 2nd file 2 minutes 3rd file 3-5 minutes 1 2.0 CONNECT TO THE CARD - TERMINAL EMULATION, TELNET OR WEB INTERFACE Upgrading the firmware requires connecting to the card with one of these interfaces. 2.1 Open the Terminal Emulation Interface - Serial Connection To connect to the card using terminal emulation software with a serial connection to the Web card: 1. Open a terminal emulation application, such as HyperTerminal. To do this: • Click the Start button, then Programs, Accessories, Communications and finally HyperTerminal. 2. In the Connection Description window, enter a name for the connection—for example, GXT2U—then click OK. 3. In the Connect To window: • Choose COM3 from the Connect Using drop-down list. • Click OK. 4. In the COM3 Properties window, enter the communication settings shown in Table 3. Table 3 Communication settings Baud Rate: Data Bits: Parity: Stop Bits: Flow Control: Name COM3 9600 8 Connection settings None 1 None 5. When the message at right appears in the HyperTerminal window, press the Enter key. 2.2 Open the Terminal Emulation Interface - TCP/IP Connection To connect to the card using terminal emulation software with an Ethernet connection to the Web card: 1. Open a terminal emulation application, such as Name HyperTerminal. To do this: • Click the Start button, then Programs, Accessories, Communications and finally HyperTerminal. 2. In the Connection Description window, enter a name for the connection—for example, GXT2U—then click OK. 3. In the Connect To window: • Choose TCP/IP (Winsock) from the Connect Using drop-down list. TCP/IP • Enter the IP address of the Web card—for example, (Winsock) 192.168.0.125—in the Host Address box, then click OK. 4. When the message at right appears in the HyperTerminal window, RTCS v2.96.00 Telnet press the Enter key. Service Port Manager <Esc> Ends Session 5. Enter the Administrator username and password (both are casesensitive): a. Login (username—default is Liebert) Login: Liebert Password: ******** b. Password (default is Liebert) 2 server Active 2.3 Open the Telnet Interface To connect to the card using Telnet: 1. Open a Telnet connection on a computer with an Ethernet connection to the Liebert unit. To do this: • Open a command prompt window—click the Start button, then Run. • Enter cmd and click OK. • In the command prompt window that opens, enter telnet followed by a space and the IP address of the Web card—for example: telnet 192.168.0.125 C:>telnet 192.168.0.125 2. When the message at right appears in the command prompt window, RTCS v2.96.00 Telnet server press the Enter key. Service Port Manager Active <Esc> Ends Session 3. Enter the Administrator username and password (both are casesensitive): a. Login (username—default is Liebert) Login: Liebert Password: ******** b. Password (default is Liebert) 2.4 Open the Web Interface To connect to the card using the Web interface: 1. Open a Web browser such as Internet Explorer. 2. Enter the IP address of the Web card in the address bar—e.g., 192.168.0.125. 3. Click on a tab at the top of the window. Configure and Support Tabs 3 3.0 PREPARING TO UPDATE LIEBERT INTELLISLOT FIRMWARE 3.1 Requirements to Update the Liebert IntelliSlot Card’s Firmware Make sure you have the following before starting the update: • Firmware upgrade downloaded from the Liebert Web site (see 3.3 - Download the Firmware Upgrade File to the Computer) • A computer running Internet Explorer 5.5 or newer • A Liebert IntelliSlot card • A connection to the Liebert IntelliSlot card • Null modem cable—serial upgrade method • Ethernet connection—TFTP or HTTP upgrade method • An Internet connection 3.2 Determine the Liebert IntelliSlot Card Type and Firmware Version Each type of Liebert IntelliSlot card uses different firmware. Attempting to upgrade a card with the firmware for another type of card will fail and may damage the card. To determine the type of card in your Liebert equipment: Terminal Emulation (Serial or TCP/IP Connection) / Telnet To view Web card information using terminal emulation or Telnet: Factory Settings Menu ---------------------1: Reset to Factory Defaults 2: Agent Card Information 1. Open a connection to the Liebert IntelliSlot card (if needed, see <ESC>: Cancel menu level instructions in 2.1 - Open the Terminal Emulation Interface Please select a key ?> Serial Connection, 2.2 - Open the Terminal Emulation Interface - TCP/IP Connection or 2.3 - Open the Telnet Interface). 2. Choose Factory Settings from the Main Menu, then choose Agent Card Information. 3. The Liebert IntelliSlot card model, part number and firmware version appear in the following example. Press the Enter key to return to the previous menu MAC Address Network Card Model Network Card Part # Manufacture Date Serial Number Boot Version Boot Label App Version App Label Hardware Version CPU Speed Flash Usage Hit Enter to Exit Model and Part Number Firmware Version 00-00-68-16-82-C1 IntelliSlot Web Card OCWEBCARD APR 28,2004 416701G105T2004APR280074 2.300.0 OCWEBCARD_HID3_2.300.0_034380 2.300.0 OCWEBCARD_HID3_2.300.0_035191 3 50 MHz 4327 Out Of 8388 KByte Web Interface To view Web card information using a Web browser: 1. Open a connection to the Liebert IntelliSlot card (if needed, see instructions in 2.4 - Open the Web Interface). 2. Click on the Support tab, then Summary in the left panel. The Liebert IntelliSlot card model, part number and firmware version appear in the right panel. Support tab Model, Part Number and Firmware Version Summary 4 3.3 Download the Firmware Upgrade File to the Computer NOTE Turn off the power management on your PC or laptop before beginning the update to ensure that communication will not be disrupted during the process. To download the upgrade file: 1. Open a Web browser, such as Internet Explorer (5.5 or newer). 2. Navigate to the Liebert Web site, www.liebert.com/downloads. 3. Choose the firmware upgrade for your card from the selections on the Web page (see 3.2 - Determine the Liebert IntelliSlot Card Type and Firmware Version). 4. Click on the link to download the file. 5. Save the file to your computer’s hard drive. Be sure to make a note of the location where the file is saved. 3.4 Choose a Method to Install the Firmware Upgrade To install the firmware upgrade, choose one of these three methods and refer to the associated stepby-step directions: • HTTP (Web) - see 4.0 - Updating the Firmware - HTTP (Web) Method • TFTP - see 5.0 - Updating the Firmware - TFTP (HyperTerminal, Telnet, Web) Method • Xmodem (Serial) - see 6.0 - Updating the Firmware - Xmodem (Serial) Method 5 4.0 UPDATING THE FIRMWARE - HTTP (WEB) METHOD Follow these steps to install the firmware upgrade using the HTTP (Web) method. This method is available through the Web interface only and requires an Ethernet connection to the Web card. 4.1 Install the Firmware Upgrade NOTE Turn off the power management on your PC or laptop before beginning the update to ensure that communication will not be disrupted during the process. To update the Liebert IntelliSlot card firmware using the HTTP (Web) method: 1. Open a connection to the Liebert IntelliSlot card (if needed, see instructions in 2.4 - Open the Web Interface). 2. Click on the Configure tab, then click on Web (under Firmware Update) in the left panel. The Connect To box opens for you to enter the username and password. 3. Enter the Administrator username and password (both case-sensitive): a. User Name (default is Liebert) b. Password (default is Liebert) 4. Click OK. The Web (HTTP) Firmware Update window opens, as shown at right below. Configure tab Browse Web Connect To Filename Update Firmware 5. Click on the Browse button to locate the upgrade file. This is the file with the extension “.bin” downloaded in 3.3 - Download the Firmware Upgrade File to the Computer. Then click Open to return to the update screen. 6. When ready to begin the update, click the Update Firmware button. A screen will appear, showing the firmware update progress. NOTE Do not refresh your browser or open another browser window. Wait until the firmware update has been completed before opening other applications or using the computer for other tasks. 7. A message appears indicating whether the update was successful. After the firmware update is completed, the card will reinitialize and you may return to the Liebert IntelliSlot card’s Web interface. Check the new firmware version if you wish (see 3.2 - Determine the Liebert IntelliSlot Card Type and Firmware Version). 6 5.0 UPDATING THE FIRMWARE - TFTP (HYPERTERMINAL, TELNET, WEB) METHOD Follow these steps to update the firmware using the TFTP method. This method is available through the terminal emulation, Telnet and Web interfaces with an Ethernet connection to the Web card. NOTE This method includes a time-sensitive operation requiring expeditious location of the upgrade files downloaded in 3.3 - Download the Firmware Upgrade File to the Computer. Read through this entire section before beginning the upgrade. 5.1 TFTP Method - Terminal Emulation / Telnet Interface To update the Liebert IntelliSlot card firmware using the TFTP method with a terminal emulation or Telnet interface: Open a Connection to the Card 1. Open a terminal emulation or Telnet connection to the Liebert IntelliSlot card (if needed, see instructions in 2.2 - Open the Terminal Emulation Interface - TCP/IP Connection or 2.3 - Open the Telnet Interface). 2. Choose Firmware Updates from the Main Menu. Firmware Updates Menu ---------------------3. Choose TFTP Update from the Firmware Updates menu, 1: TFTP Update shown at right. Specify TFTP Server and Upgrade Filename 4. The TFTP Update Menu, shown at right, displays the TFTP server’s IP address and listening port, along with the name of the firmware update file. 5. Select options as needed and refer to the following guide to change any settings. Table 4 TFTP Update Menu ----------------1: IP Address 0.0.0.0 2: Port 69 3: Filename Uninitialized 4: Initiate TFTP Firmware Update <ESC>: Cancel menu level Please select a key ?> Firmware update settings - TFTP Parameter Description Server The IP address of the TFTP server—for example, 192.168.0.125. Port Port that the TFTP server is using, typically 69. Filename Name of the firmware update file—128 characters maximum, including spaces and punctuation. This is the file with the extension “.bin” downloaded in 3.3 - Download the Firmware Upgrade File to the Computer. 6. After making changes, press the Escape key twice to return to the Main Menu. 7. Choose Exit and Save to save your changes and reboot the card. Reconnect to the Card 8. Connect to the Liebert IntelliSlot card again (if needed, see 2.3 - Open the Telnet Interface or 2.1 - Open the Terminal Emulation Interface - Serial Connection). 9. Choose Firmware Updates from the Main Menu. Firmware Updates Menu ---------------------10. Choose TFTP Update from the Firmware Updates menu, 1: TFTP Update shown at right. 7 Begin the Upgrade Process 11. When ready to begin the update, choose Initiate TFTP Firmware Update. 12. Open the TFTP application and start TFTP. Ensure that all settings are ready to transfer the file, including the location of the upgrade file. Refer to your TFTP user manual for more details. 13. Return to the terminal emulation/Telnet screen. At the confirmation message prompt, enter y (yes) to confirm your choice. (To cancel, enter n for no.) 14. A message appears, as shown at right, showing the progress by percent complete. 15. When the progress screen shows 100% complete, the card will be rebooted. Press Enter when this is finished. 16. Press the Escape key to return to the Main Menu, then choose Exit and Save. The upgrade is now complete. Check the new firmware version if you wish (see 3.2 - Determine the Liebert IntelliSlot Card Type and Firmware Version). TFTP Update Menu ----------------1: IP Address 192.168.0.125 2: Port 69 3: Filename OCWEBCARD_HID3_2.300.0_035780_AppFwUpdt.bin 4: Initiate TFTP Firmware Update <ESC>: Cancel menu level Please select a key ?> All Code In Flash Will Be Rewritten, Confirm? [y/n] TFTP Update initiated The firmware on this card is currently being updated. This operation may take 6 or more minutes depending on network traffic and other factors. The card will be rebooted upon successful completion of the process OR control will be returned to this terminal session upon failure so another firmware update attempt can be made. Firmware update in process... Percent Complete(0%) Main Menu ---------1: System Information 2: IP Network Settings 3: Messaging 4: Factory Settings 5: Firmware Updates q: Quit and abort changes x: Exit and save Please select a key ?> 8 5.2 TFTP Method - Web Interface To update the Liebert IntelliSlot card firmware using the TFTP method with a Web interface: Open a Connection to the Card 1. Open a connection to the Liebert IntelliSlot card (if needed, see instructions in 2.4 - Open the Web Interface). 2. Click on the Configure tab, then TFTP in the left panel. Configure tab Edit TFTP 3. Enter the Administrator username and password (both are case-sensitive): a. Login (username—default is Liebert) b. Password (default is Liebert) Specify TFTP Server and Upgrade Filename 4. Click the Edit button in the right panel. 5. Select options as needed and refer to the following guide to change any settings. Table 5 Firmware update settings - Web Parameter Description Server The IP address of the TFTP server—for example, 192.168.0.125. Port Port that the TFTP server is using, typically 69. Filename Name of the firmware update file—128 characters maximum, including spaces and punctuation. This is the file with the extension “.bin” downloaded in 3.3 - Download the Firmware Upgrade File to the Computer. 6. After making changes, click Save, then click Reinitialize in the left panel to reboot the card. Configure tab Save TFTP Reinitialize Reconnect to the Card 7. Click the Configure tab, then TFTP and enter the username and password (Steps 2 and 3) to return to the TFTP screen as shown above. 9 Begin the Upgrade Process 8. Open the TFTP application and start TFTP. Ensure that all settings are ready to transfer the file, including the location of the upgrade file. Refer to your TFTP user manual for more details. 9. Return to the Web interface. 10. When ready to begin the download, click the Update Firmware button. Update Firmware 11. During the update, the window displays a progress bar, as shown below left. NOTE Do not close the Web browser during this process or the update will abort. After the firmware update is completed, the card will reinitialize automatically. A reboot message, as shown below right, remains until the rebooting is finished. Progress of update When the rebooting is complete, the Web browser window returns to the default opening view. The upgrade is now complete. Check the new firmware version if you wish (see 3.2 - Determine the Liebert IntelliSlot Card Type and Firmware Version). 10 6.0 UPDATING THE FIRMWARE - XMODEM (SERIAL) METHOD Follow these steps to update the firmware using the Xmodem (serial) method. This method works through the Web card’s serial port, employing terminal emulation software, such as HyperTerminal. NOTE This method includes a time-sensitive operation requiring expeditious location of the upgrade files downloaded in 3.3 - Download the Firmware Upgrade File to the Computer. Read through this entire section before beginning the upgrade. Connect a Cable to the Serial Ports 1. Connect one end of a DB-9 null modem or file transfer cable to the Web card’s serial port and the other to the computer’s serial port. The correct cable will have, at a minimum, Pins 2 and 3 crossed at the ends, as shown in Figure 1. The configuration cable is available separately from Emerson (P/N LIEBNULL). Figure 1 Null connection DTE Device DTE Device Receive Rx (Pin 2) Receive Rx (Pin 2) Transmit Tx (Pin 3) Transmit Tx (Pin 3) Open a Terminal Emulation Connection 2. Open a connection to the Liebert IntelliSlot card (if needed, see instructions in 2.1 - Open the Terminal Emulation Interface - Serial Connection). 3. Choose Firmware Updates from the Main Menu. 4. Choose XMODEM Update from the Firmware Updates menu, seen at right, and enter y (yes) to confirm your choice. 5. Choose Xmodem1K from the Select Firmware Update Protocol, as shown at right. Firmware Updates Menu ---------------------1: XMODEM Update 2: TFTP Update Firmware Update (Step 1/3) -------------------------Select Firmware Update Protocol ------------------------------1: XmodemCrc 2: Xmodem1K x: Exit/Cancel Please select a key ?> Current Communications Rate is 9600 bps. Change the Baud Rate to 115200 6. Choose 115200 bps from the menu, shown below left. 7. From the HyperTerminal menu, click on Call, then choose Disconnect (this will not close the HyperTerminal connection to the card). 8. In the HyperTerminal menu bar, click on File, then choose Properties. 9. Click on the Connect To tab and click the Configure button. This opens Port Settings tab in the COM1 Properties window, as shown below right. 10. Choose 115200 from the Bits Per Second drop-down list and click OK, then click OK to close the Properties window. 11. In the HyperTerminal menu bar, click on Call, then choose Call from the drop-down menu and press the Enter key. 115200 bps Call menu 115200 bps Configure button 11 Download the First Firmware Update File 12. After changing the communication rate to 115200 bps, press Enter to resume the firmware update. After you press Enter, HyperTerminal displays Cs as it counts down the time remaining to locate and begin transferring the upgrade files. NOTE After you begin the initialization process in Step 12, you must complete Steps 13 through 15 within 60 seconds. Before beginning, check to ensure that you know the location of the firmware files and read through the following steps to understand what needs to be done. This 60-second limit also applies to downloading the second and third upgrade files. 13. In the HyperTerminal menu, click on Transfer, then Send File. Browse to locate upgrade file Press Enter to start firmware update Progress ... and window remaining shows time elapsed time... Choose 1K Xmodem 14. Click the Browse button to locate an upgrade file. Select the files in order—the filename ending in FILE1 for the first download, then FILE2, and finally FILE3—then click Open. 15. In the Send File window, choose 1K Xmodem from the Protocol drop-down list and click Send. A progress window opens, showing the elapsed time and amount of time remaining for the first file to be downloaded to the Liebert IntelliSlot card. The window closes after the first file is downloaded. NOTE Do not press any keys while the progress window remains open or the download will abort. Download the Second and Third Firmware Update Files 16. When the progress window closes, enter y (yes) in HyperTerminal to continue the upgrade. 17. Choose Xmodem1K in the Select Firmware Update Protocol menu. 18. The screen shows that the communication rate is 115200. This does not need to be changed. 19. Press Enter to continue. 20. Repeat Steps 12 through 15 within the 60-second limit to browse to the second upgrade file and download it to the Liebert IntelliSlot card. 21. Wait for the Progress window to close after the second file is downloaded. Then repeat Steps 16 through 20 to download the third upgrade file. This file is the largest and may take 30 minutes or longer to download. 12 Would You Like to Continue (Y or N)? Firmware Update (Step 2/3) -------------------------Select Firmware Update Protocol ------------------------------1: XmodemCrc 2: Xmodem1K x: Exit/Cancel Please select a key ?> Current Communications Rate is 115200 bps. Press a number to Change Communications Rate. ------------------------------1: 9600 bps 2: 19200 bps 3: 38400 bps 4: 57600 bps 5: 115200 bps Enter: Accept/Start Firmware Update Please select a key > Press Enter to Start Firmware Update. Complete the Upgrade and Restore Communication Rate 22. Choose 9600 bps from the menu, shown below left. 23. From the HyperTerminal menu, click on Call, then choose Disconnect (this will not close the HyperTerminal connection to the card). 24. In the HyperTerminal menu bar, click on File, then choose Properties. 25. Click on the Connect To tab and click the Configure button. This opens Port Settings tab in the COM1 Properties window, as shown below right. 26. Choose 9600 from the Bits Per Second drop-down list and click OK, then click OK to close the Properties window. 27. In the HyperTerminal menu bar, click on Call, then choose Call from the drop-down menu. 28. Press the Enter key. Call menu 9600 bps Configure button 29. Choose Exit and Save from the Main Menu to reboot the card. When rebooting is complete, the upgrade is finished. Check the new firmware version if you wish (see 3.2 - Determine the Liebert IntelliSlot Card Type and Firmware Version). Main Menu ---------1: System Information 2: IP Network Settings 3: Messaging 4: Factory Settings 5: Firmware Updates q: Quit and abort changes x: Exit and save Please select a key ?> 5 13 14 Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, the global leader in enabling business-critical continuity, ensures network resiliency and adaptability through a family of technologies—including Liebert power and cooling technologies—that protect and support business-critical systems. Liebert solutions employ an adaptive architecture that responds to changes in criticality, density and capacity. Enterprises benefit from greater IT system availability, operational flexibility and reduced capital equipment and operating costs. Technical Support / Service Web Site www.liebert.com Monitoring [email protected] 800-222-5877 Outside North America: +00800 1155 4499 Single-Phase UPS & Server Cabinets [email protected] 800-222-5877 Outside North America: +00800 1155 4499 Three-Phase UPS & Power Systems 800-543-2378 Outside North America: 614-841-6598 Environmental Systems 800-543-2778 Outside the United States: 614-888-0246 Locations United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy +39 049 9719 111 Fax: +39 049 5841 257 Asia 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 1605 Philippines +63 2 687 6615 Fax: +63 2 730 9572 While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2007 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-52625_REV02_12-09 Emerson Network Power. The global leader in enabling Business-Critical Continuity. Embedded Computing AC Power Embedded Power Connectivity DC Power Monitoring Outside Plant Power Switching & Controls Precision Cooling EmersonNetworkPower.com Racks & Integrated Cabinets Services Surge Protection Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.