Features
• Two chips are matched for uniform light output, wide viewing angle
• Long life-solid state reliability
• I.C. compatible/Low power consumption
• The product itself will remain within RoHS compliant version
• Compliance with EU REACH
• Compliance Halogen Free .(Br <900 ppm ,Cl <900 ppm , Br+Cl < 1500 ppm)
Description
• The 339-1 LED lamp contain two integral chips and is available as both bicolor and bipolar types.
• The Brilliant Red and Brilliant Yellow Green light is emitted by diodes of AlGaInP and AlGaInP
• Type of bipolar lamps are both White Clear and Color Clear while the bicolor are Water Clear
Applications
• TV set
• Monitor
• Telephone
• Computer
1 Copyright
Revision
:2 ©
LifecyclePhase:
Date:2014-12-15
09:57:02.0
www.everlight.com
2010, Everlight All Rights Reserved. Release Date : Dec.11 .2014 . IssueRelease
No: D LE-0007419
_Rev.2
Expired Period: Forever
DATASHEET
LAMP
339-1SURSYGC/S530-A3
Device Selection Guide
Chip
Emitted Color
Materials
Resin Color
AlGaInP
Brilliant Red
AlGaInP
Brilliant Yellow Green
Water Clear
Absolute Maximum Ratings (Ta=25℃)
Parameter
Symbol
Continuous Forward Current
IF
Peak Forward Current (Duty 1/10 @ 1KHZ)
IFP
Reverse Voltage
VR
Rating
SUR
SYG
SUR
SYG
Unit
25
25
60
60
mA
mA
5
Power Dissipation
Pd
Operating Temperature
Topr
SUR
60
SYG
60
-40 ~ +85
Storage Temperature
Tstg
-40 ~ +100
Soldering Temperature
Tsol
V
mW
℃
℃
260 ℃ for 5 sec.
Electro-Optical Characteristics (Ta=25℃)
Parameter
Symbol
Forward Voltage
VF
Reverse Current
IR
Luminous Intensity
IV
Viewing Angle
2θ1/2
Peak Wavelength
λp
Dominant Wavelength
λd
Spectrum Radiation Bandwidth
△λ
2 Copyright
Revision
:2 ©
LifecyclePhase:
Min.
Typ.
Max.
SUR
1.7
2.0
2.4
SYG
1.7
2.0
2.4
SUR
-----
-----
10
SYG
-----
-----
10
SUR
160
250
----
SYG
40
63
----
SUR
----
25
-----
SYG
----
25
----
SUR
----
632
----
SYG
----
575
----
SUR
----
624
----
SYG
----
573
----
SUR
----
20
----
SYG
----
20
----
Unit
Condition
V
IF=20mA
μA
VR=5V
mcd
IF=20mA
deg
IF=20mA
nm
IF=20mA
nm
IF=20mA
nm
IF=20mA
Date:2014-12-15
09:57:02.0
www.everlight.com
2010, Everlight All Rights Reserved. Release Date : Dec.11 .2014 . IssueRelease
No: D LE-0007419
_Rev.2
Expired Period: Forever
DATASHEET
LAMP
339-1SURSYGC/S530-A3
Typical Electro-Optical Characteristics Curves
SUR
Directivity (Ta=25℃)
Radiation Angle
Relative Intensity (a.u.)
Relative Intensity vs. Wavelength (Ta=25℃)
Wavelength (nm)
Relative Intensity (a.u.)
Forward Current vs. Forward Voltage (Ta=25℃)
Relative Intensity vs. Forward Current (Ta=25℃)
Forward Current (mA)
Relative Intensity(a.u.)
1.5
1.0
0.5
0.0
0
Forward Voltage (V)
Forward Current (mA)
Relative Intensity (a.u.)
20
25
40
1.5
1.0
0.5
30
20
10
0
30
35
40
45
50
55
60
Forward Current (mA)
LifecyclePhase:
15
Forward Current vs. Ambient Temp.
2.0
3 Copyright
Revision
:2 ©
10
Forward Current (mA)
Relative Intensity vs. Ambient Temp.
0.0
25
5
65
70
0
20
40
60
80
100
Ambient Temperature Ta(℃)
Date:2014-12-15
09:57:02.0
www.everlight.com
2010, Everlight All Rights Reserved. Release Date : Dec.11 .2014 . IssueRelease
No: D LE-0007419
_Rev.2
Expired Period: Forever
DATASHEET
LAMP
339-1SURSYGC/S530-A3
SYG
Directivity (Ta=25℃)
Radiation Angle
Relative Intensity (a.u.)
Relative Intensity vs. Wavelength (Ta=25℃)
Wavelength (nm)
Relative Intensity (a.u.)
Forward Current vs. Forward Voltage (Ta=25℃)
Relative Intensity vs. Forward Current (Ta=25℃)
Forward Current (mA)
Relative Intensity(a.u.)
1.5
1.0
0.5
0.0
0
Forward Voltage (V)
Chromaticity Coordinate vs. Forward Current(Ta=25℃)
Forward Current (mA)
Relative Intensity (a.u.)
15
20
25
40
1.5
1.0
0.5
0.0
25
30
35
40
45
50
55
60
Forward Current (mA)
LifecyclePhase:
10
Forward Current vs. Ambient Temp.
2.0
4 Copyright
Revision
:2 ©
5
Forward Current (mA)
65
70
30
20
10
0
0
20
40
60
80
100
Ambient Temperature Ta(℃)
Date:2014-12-15
09:57:02.0
www.everlight.com
2010, Everlight All Rights Reserved. Release Date : Dec.11 .2014 . IssueRelease
No: D LE-0007419
_Rev.2
Expired Period: Forever
DATASHEET
LAMP
339-1SURSYGC/S530-A3
Package Dimension
Note: Note:
1. All dimensions are in millimeters
2. The height of flange must be less than 1.5mm(0.059").
3. Without special declared, the tolerance is ±0.25mm.
5 Copyright
Revision
:2 ©
LifecyclePhase:
Date:2014-12-15
09:57:02.0
www.everlight.com
2010, Everlight All Rights Reserved. Release Date : Dec.11 .2014 . IssueRelease
No: D LE-0007419
_Rev.2
Expired Period: Forever
DATASHEET
LAMP
339-1SURSYGC/S530-A3
Moisture Resistant Packing Materials
Label Explanation
Pb
CPN: Customer's
EVERLIGHT
X
Production Number
P/N : Production Number
QTY: Packing Quantity
RoHS
CAT: Ranks of Luminous Intensity
HUE: Ranks of Dominant Wavelength
339-1SURSYGC/S530-A3
REF: Ranks of Forward Voltage
LOT No: Lot Number
Packing Specification
■ Anti-electrostatic bag
■ Inner Carton
■ Outside Carton
Pb
EL ECTR OSTATIC ELECTR ONAGNET IC
MAGNETIC OR RADIOACTIVE RELDS
anti-static for 750
■ Packing Quantity
1.Min 200 To 500 PCS/1 Bag, 4 Bags/1 Inner Carton
2. 10 Inner Cartons/1 Outside Carton
6 Copyright
Revision
:2 ©
LifecyclePhase:
Date:2014-12-15
09:57:02.0
www.everlight.com
2010, Everlight All Rights Reserved. Release Date : Dec.11 .2014 . IssueRelease
No: D LE-0007419
_Rev.2
Expired Period: Forever
DATASHEET
LAMP
339-1SURSYGC/S530-A3
Notes
1.
Lead Forming

During lead formation, the leads should be bent at a point at least 3mm from the base of the epoxy bulb.

Lead forming should be done before soldering.

Avoid stressing the LED package during leads forming. The stress to the base may damage the LED’s characteristics or it
may break the LEDs.

Cut the LED leadframes at room temperature. Cutting the leadframes at high temperatures may cause failure of the LEDs.

When mounting the LEDs onto a PCB, the PCB holes must be aligned exactly with the lead position of the LED. If the LEDs
are mounted with stress at the leads, it causes deterioration of the epoxy resin and this will degrade the LEDs.
2.
Storage

The LEDs should be stored at 30°C or less and 70%RH or less after being shipped from Everlight and the storage life limits
are 3 months. If the LEDs are stored for 3 months or more, they can be stored for a year in a sealed container with a
nitrogen atmosphere and moisture absorbent material.

Please avoid rapid transitions in ambient temperature, especially, in high humidity environments where condensation can
occur.
3.
Soldering

Careful attention should be paid during soldering. When soldering, leave more then 3mm from solder joint to epoxy bulb,
and soldering beyond the base of the tie bar is recommended.
Recommended soldering conditions:

Hand Soldering
300℃ Max. (30W Max.)
Temp. at tip of iron
Soldering time
3 sec Max.
Distance
3mm Min.(From solder
joint to epoxy bulb)
Recommended soldering profile

Avoiding applying any stress to the lead frame while the LEDs are at high temperature particularly when soldering.

Dip and hand soldering should not be done more than one time

After soldering the LEDs, the epoxy bulb should be protected from mechanical shock or vibration until the LEDs return to
Preheat temp.
Bath temp. & time
Distance
DIP Soldering
100℃ Max. (60 sec Max.)
260 Max., 5 sec Max
3mm Min. (From solder
joint to epoxy bulb)
room temperature.

A rapid-rate process is not recommended for cooling the LEDs down from the peak temperature.

Although the recommended soldering conditions are specified in the above table, dip or hand soldering at the lowest
possible temperature is desirable for the LEDs.
7 Copyright
Revision
:2 ©
LifecyclePhase:
Date:2014-12-15
09:57:02.0
www.everlight.com
2010, Everlight All Rights Reserved. Release Date : Dec.11 .2014 . IssueRelease
No: D LE-0007419
_Rev.2
Expired Period: Forever
DATASHEET
LAMP
339-1SURSYGC/S530-A3

Wave soldering parameter must be set and maintain according to recommended temperature and dwell time in the solder
wave.
4.
Cleaning

When necessary, cleaning should occur only with isopropyl alcohol at room temperature for a duration of no more than
one minute. Dry at room temperature before use.

Do not clean the LEDs by the ultrasonic. When it is absolutely necessary, the influence of ultrasonic cleaning on the LEDs
depends on factors such as ultrasonic power and the assembled condition. Ultrasonic cleaning shall be pre-qualified to
ensure this will not cause damage to the LED
5.
Heat Management

Heat management of LEDs must be taken into consideration during the design stage of LED application. The current
should be de-rated appropriately by referring to the de-rating curve found in each product specification.

The temperature surrounding the LED in the application should be controlled. Please refer to the data sheet de-rating
curve.
6.
ESD (Electrostatic Discharge)

The products are sensitive to static electricity or surge voltage. ESD can damage a die and its reliability.
When handling the products, the following measures against electrostatic discharge are strongly recommended:
Eliminating the charge
Grounded wrist strap, ESD footwear, clothes, and floors
Grounded workstation equipment and tools
ESD table/shelf mat made of conductive materials

Proper grounding is required for all devices, equipment, and machinery used in product assembly.
Surge protection should be considered when designing of commercial products.

If tools or equipment contain insulating materials such as glass or plastic,
the following measures against electrostatic discharge are strongly recommended:
Dissipating static charge with conductive materials
Preventing charge generation with moisture
Neutralizing the charge with ionizers
7.
Directions for use

The LEDs should be operated with forward bias. The driving circuit must be designed so that the LEDs are not subjected
to forward or reverse voltage while it is off. If reverse voltage is continuously applied to the LEDs, it may cause migration
resulting in LED damage.
8.
Other

Above specification may be changed without notice. EVERLIGHT will reserve authority on material change for above
specification.

When using this product, please observe the absolute maximum ratings and the instructions for using outlined in these
specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which does
not comply
with the absolute maximum ratings and the instructions included in these specification sheets.

These specification sheets include materials protected under copyright of EVERLIGHT corporation. Please don’t
reproduce or cause anyone to reproduce them without EVERLIGHT’s consent.
8 Copyright
Revision
:2 ©
LifecyclePhase:
Date:2014-12-15
09:57:02.0
www.everlight.com
2010, Everlight All Rights Reserved. Release Date : Dec.11 .2014 . IssueRelease
No: D LE-0007419
_Rev.2
Expired Period: Forever