204-10SYGC/S530-E2

LAMP
204-10SYGC/S530-E2
Features
• Choice of various viewing angles
• Available on tape and reel.
• Reliable and robust
• The product itself will remain within RoHS compliant version.
• Compliance with EU REACH
• Compliance Halogen Free .(Br <900 ppm ,Cl <900 ppm , Br+Cl < 1500 ppm)
Description
•The series is specially designed for applications requiring higher brightness
•The led lamps are available with different colors, intensities..
Applications
• TV set
• Monitor
• Telephone
• Computer
1
Copyright © 2010, Everlight All Rights Reserved. Release Date : Aug.28. 2014. Issue No: DLE-0007125_Rev.3
www.everlight.com
DATASHEET
LAMP
204-10SYGC/S530-E2
Device Selection Guide
Chip
Emitted Color
Materials
AlGaInP
Resin Color
Water Color
Brilliant Yellow Green
Absolute Maximum Ratings (Ta=25℃
℃)
Parameter
Symbol
Rating
Unit
Continuous Forward Current
IF
25
mA
Peak Forward Current (Duty 1/10 @ 1KHZ)
IFP
60
mA
Reverse Voltage
VR
5
V
Pd
60
mW
Operating Temperature
Topr
-40 ~ +85
Storage Temperature
Tstg
-40 ~ +100
Soldering Temperature
Tsol
Power Dissipation
260
℃ for 5 sec.
℃
℃
Electro-Optical Characteristics (Ta=25℃
℃)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Condition
Iv
125
250
-----
mcd
IF=20mA
2θ1/2
-----
20
-----
deg
IF=20mA
Peak Wavelength
λp
-----
575
-----
nm
IF=20mA
Dominant Wavelength
λd
-----
573
-----
nm
IF=20mA
Spectrum Radiation Bandwidth
∆λ
-----
20
-----
nm
IF=20mA
Forward Voltage
VF
1.7
2.0
2.4
V
IF=20mA
Reverse Current
IR
-----
-----
10
µA
VR=5V
Luminous Intensity
Viewing Angle
2
Copyright © 2010, Everlight All Rights Reserved. Release Date : Aug.28. 2014. Issue No: DLE-0007125_Rev.3
www.everlight.com
DATASHEET
LAMP
204-10SYGC/S530-E2
Typical Electro-Optical Characteristics Curves
SYG
℃)
℃)
Directivity (Ta=25
Radiation Angle
Relative Intensity (a.u.)
Relative Intensity vs. Wavelength (Ta=25
Wavelength (nm)
Relative Intensity (a.u.)
℃)
Forward Current vs. Forward Voltage (Ta=25
℃)
Relative Intensity vs. Forward Current (Ta=25
Forward Current (mA)
Relative Intensity(a.u.)
1.5
1.0
0.5
0.0
0
Forward Voltage (V)
20
25
40
Forward Current (mA)
Relative Intensity(a.u.)
15
Forward Current vs. Ambient Temp.
2.0
1.5
1.0
0.5
30
35
40
45
50
55
60
65
Ambient Temperature Ta(℃)
3
10
Forward Current (mA)
Relative Intensity vs. Ambient Temp.
0.0
25
5
70
30
20
10
0
0
20
40
60
80
100
Ambient Temperature Ta(℃)
Copyright © 2010, Everlight All Rights Reserved. Release Date : Aug.28. 2014. Issue No: DLE-0007125_Rev.3
www.everlight.com
DATASHEET
LAMP
204-10SYGC/S530-E2
Package Dimension
Note: Note:
1. All dimensions are in millimeters
2. The height of flange must be less than 1.5mm(0.059").
3. Without special declared, the tolerance is ±0.25mm.
4
Copyright © 2010, Everlight All Rights Reserved. Release Date : Aug.28. 2014. Issue No: DLE-0007125_Rev.3
www.everlight.com
DATASHEET
LAMP
204-10SYGC/S530-E2
Moisture Resistant Packing Materials
Label Explanation
CPN: Customer's
Pb
EVERLIGHT
X
Production Number
P/N : Production Number
QTY: Packing Quantity
RoHS
CAT: Ranks of Luminous Intensity
HUE: Ranks of Dominant Wavelength
204-10SYGC/S530-E2
REF: Ranks of Forward Voltage
LOT No: Lot Number
Packing Specification
■ Anti-electrostatic bag
■ Inner Carton
■ Outside Carton
Pb
EL ECTROSTATIC ELECTRONAGNETIC
MAGNETICOR RADIOACTIVE RELDS
anti-static for 750
■ Packing Quantity
1. Min 200 To 1000 PCS/1 Bag, 4 Bags/1 Inner Carton
2. 10 Inner Cartons/1 Outside Carton
5
Copyright © 2010, Everlight All Rights Reserved. Release Date : Aug.28. 2014. Issue No: DLE-0007125_Rev.3
www.everlight.com
DATASHEET
LAMP
204-10SYGC/S530-E2
Notes
1.
Lead Forming
During lead formation, the leads should be bent at a point at least 3mm from the base of the epoxy bulb.
Lead forming should be done before soldering.
Avoid stressing the LED package during leads forming. The stress to the base may damage the LED’s characteristics or it
may break the LEDs.
Cut the LED lead frames at room temperature. Cutting the lead frames at high temperatures may cause failure of the LEDs.
When mounting the LEDs onto a PCB, the PCB holes must be aligned exactly with the lead position of the LED. If the LEDs
are mounted with stress at the leads, it causes deterioration of the epoxy resin and this will degrade the LEDs.
2.
Storage
The LEDs should be stored at 30°C or less and 70%RH or less after being shipped from Everlight and the storage life limits
are 3 months. If the LEDs are stored for 3 months or more, they can be stored for a year in a sealed container with a
nitrogen atmosphere and moisture absorbent material.
Please avoid rapid transitions in ambient temperature, especially, in high humidity environments where condensation can
occur.
3.
Soldering
Careful attention should be paid during soldering. When soldering, leave more then 3mm from solder joint to epoxy bulb,
and soldering beyond the base of the tie bar is recommended.
Recommended soldering conditions:
Hand Soldering
300 Max. (30W Max.)
Temp. at tip of iron
Soldering time
3 sec Max.
Distance
3mm Min.(From solder
joint to epoxy bulb)
Recommended soldering profile
℃
Preheat temp.
Bath temp. & time
Distance
DIP Soldering
100 Max. (60 sec Max.)
260 Max., 5 sec Max
3mm Min. (From solder
joint to epoxy bulb)
℃
laminar wave
Fluxing
Preheat
Avoiding applying any stress to the lead frame while the LEDs are at high temperature particularly when soldering.
Dip and hand soldering should not be done more than one time
After soldering the LEDs, the epoxy bulb should be protected from mechanical shock or vibration until the LEDs return to
room temperature.
6
A rapid-rate process is not recommended for cooling the LEDs down from the peak temperature.
Copyright © 2010, Everlight All Rights Reserved. Release Date : Aug.28. 2014. Issue No: DLE-0007125_Rev.3
www.everlight.com
DATASHEET
LAMP
204-10SYGC/S530-E2
Although the recommended soldering conditions are specified in the above table, dip or hand soldering at the lowest
possible temperature is desirable for the LEDs.
Wave soldering parameter must be set and maintain according to recommended temperature and dwell time in the solder
wave.
4.
Cleaning
When necessary, cleaning should occur only with isopropyl alcohol at room temperature for a duration of no more than
one minute. Dry at room temperature before use.
Do not clean the LEDs by the ultrasonic. When it is absolutely necessary, the influence of ultrasonic cleaning on the LEDs
depends on factors such as ultrasonic power and the assembled condition. Ultrasonic cleaning shall be pre-qualified to
ensure this will not cause damage to the LED
5.
Heat Management
Heat management of LEDs must be taken into consideration during the design stage of LED application. The current
should be de-rated appropriately by referring to the de-rating curve found in each product specification.
The temperature surrounding the LED in the application should be controlled. Please refer to the data sheet de-rating
curve.
6. ESD (Electrostatic Discharge)
The products are sensitive to static electricity or surge voltage. ESD can damage a die and its reliability.
When handling the products, the following measures against electrostatic discharge are strongly
recommended:
Eliminating the charge
Grounded wrist strap, ESD footwear, clothes, and floors
Grounded workstation equipment and tools
ESD table/shelf mat made of conductive materials
Proper grounding is required for all devices, equipment, and machinery used in product assembly.
Surge protection should be considered when designing of commercial products.
If tools or equipment contain insulating materials such as glass or plastic,
the following measures against electrostatic discharge are strongly recommended:
Dissipating static charge with conductive materials
Preventing charge generation with moisture
Neutralizing the charge with ionizers
7.
Directions for use
The LEDs should be operated with forward bias. The driving circuit must be designed so that the LEDs are not subjected
to forward or reverse voltage while it is off. If reverse voltage is continuously applied to the LEDs, it may cause migration
resulting in LED damage.
8.
Other
Above specification may be changed without notice. EVERLIGHT will reserve authority on material change for above
specification.
When using this product, please observe the absolute maximum ratings and the instructions for using outlined in these
specification sheets. EVERLIGHT assumes no responsibility for any damage resulting from use of the product which does
not comply
with the absolute maximum ratings and the instructions included in these specification sheets.
7
These specification sheets include materials protected under copyright of EVERLIGHT corporation. Please don’t
Copyright © 2010, Everlight All Rights Reserved. Release Date : Aug.28. 2014. Issue No: DLE-0007125_Rev.3
www.everlight.com
DATASHEET
LAMP
204-10SYGC/S530-E2
reproduce or cause anyone to reproduce them without EVERLIGHT’s consent.
8
Copyright © 2010, Everlight All Rights Reserved. Release Date : Aug.28. 2014. Issue No: DLE-0007125_Rev.3
www.everlight.com