150W Open Frame Medical Power Supply MP-150 series Features: Universal AC input / Full range with active PFC 4"x 2" footprint Medical safety approval: ANSI / AAMI ES 60601-1 / TUV EN 60601-1; IEC 60601-1 / 2xMOPP 100W convection cooling and 150W with 10.5 CFM forced air Protection: Short circuit, Over load, Over voltage High operation temperature up to 70°C Built-in fan supply Withstand 2G vibration test 3 years warranty MEDICAL MP-150-12 MODEL DC Voltage Range Rated Current Current Range (Convection) Current Range (20 CFM Fan) Rated Power (Convection) Rated Power (20 CFM Fan) Output Input Ripple & Noise (Max.) Voltage Adj. Range Voltage Tolerance Line Regulation Load Regulation Setup, Rise Time Hold Up Time Voltage Range Frequency Range Efficiency (Typ.) at 230VAC AC Current (Typ.) Inrush Current (Typ.) Leakage Current Over Load Protection Over Voltage Environment Working Temp. Working Humidity Storage Temp. & Humidity Temp. Coefficient Vibration Safety Standards Safety & EMC Others Note MP-150-15 E324816 MP-150-48 MP-150-24 15V 12V 24V 12.5A 10A 6.25A 0 ~ 8.3A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 12.5A 0 ~ 10A 0 ~ 6.25A 99.6W 100.5W 100.8W 150W 150W 150W 120mVp-p 150mVp-p 240mVp-p ±10% ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 2000ms, 50ms / 230VAC, 3500ms, 50ms / 115VAC at full load 16ms / 230VAC, 16ms / 115VAC at full load 90 ~ 264VAC, 127 ~ 373VDC 47 ~ 63Hz 90% 91% 90% 1.72A / 100VAC, 0.73A / 240VAC Cold Start 30A / 115VAC, 60A / 230VAC For earth < 275uA / 264VAC, For patient < 100uA / 264VAC Above 110% rated output power Protection type: latch-style (Recovery after reset AC power ON) 115 ~ 140% rated output voltage Protection type: latch-style (Recovery after reset AC power ON) -20 ~ 70°C (Refer to output load de-rating curve) 20 ~ 90% RH non-condensing -40 ~ +85°C, 10 ~ 95% RH ±0.03% / °C (0 ~ 50°C) 48V 3.125A 0 ~ 2.1A 0 ~ 3.125A 100.8W 150W 480mVp-p ±2.0% ±1.0% ±1.0% 91% 10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Meets UL / cUL (ANSI / AAMI ES 60601-1; CAN / CSA-C22.2 No.60601-1); NFPA 99 Meets TUV (EN 60601-1; IEC 60601-1); MOPP approval I/P-O/P: 4KVAC, I/P-FG: 1.8KVAC, O/P-FG: 1.5KVAC Withstand Voltage Isolation Resistance I/P-O/P: 100M Ohms / 500VDC EMI Conduction & Radiation Certified EN 55011 Certified EN 61000-3-2; EN 61000-3-3 Harmonic Current Certified EN 60601-1-2; IEC 61000-4-2, 3, 4, 5, 6, 8, 11 EMS Immunity XXX K HRS Certified MIL-HDBK-217F MTBF Free Air convection for 100W, with 20 CFM Fan for 150W Cooling Dimension (WxHxD) 50.8x32.1x101.6 mm / 2.00x1.26x4.00 inch Packing XXX kg 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. *Note:The specifications are subject to change without notice. REV. A2 14/02/20 1 150W Open Frame Medical Power Supply MP-150 series Mechanical Specification: Unit : mm AC Input Connector (CN1): JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC / N N.C AC / L Mating Housing / Contact JST VHR-3N or equivalent JST SVH-21T-P1.1 or equivalent External Fan Power Connector (CN2): JST B2B-XH-A or equivalent Pin No. 1 2 Assignment GND +12V Mating Housing / Contact JST XHP-2 JST SXH-001T-P0.6 or equivalent or equivalent 10.5CFM FAN DC Output Connector (CN3): JST B6P-VH or equivalent Pin No. 1,2,3 4,5,6 Assignment +VO -VO 50mm AIR flow direction Mating Housing / Contact JST VHR-6N JST SVH-41T-P1.1 or equivalent or equivalent Block Diagram: RECTIFIERS & FILTER EMI FILTER I/P PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER +V -V Fan RECTIFIERS & FILTER +V -V Output DETECTION CIRCUIT O.L.P. FG CONTROL O.V.P. De-rating Curve: Load V.S Temp. Load V.S I/P Voltage Ta=25°C With 10.5CFM Free Air Convection 100 100 90 Load (%) Load (%) 80 66 60 70 60 Free Air Convection 40 80 50 20 -20 40 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 90 95 100 115 120 140 160 180 264Vac Input Voltage (Vac) 60Hz *Note:The specifications are subject to change without notice. REV. A2 14/02/20 2