RPD-60 60W Dual Output Medical Type series Features : 4" 2" miniature size Universal AC input/Full range Low leakage current<200uA Protections: Short circuit / Over load / Over voltage Cooling by free air convection ANSI/AAMI ES60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved Fixed switch frequency at 100KHz 3 years warranty SPECIFICATION MODEL OUTPUT INPUT RPD-60A CH1 CH2 CH1 CH2 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 5A 2A 3.5A 1.5A CURRENT RANGE 0.5 ~ 5.5A 0.1 ~ 2.2A 0.5 ~ 3.85A 0.1 ~ 1.65A RATED POWER 49W PEAK LOAD(10sec.) 80mVp-p 100mVp-p VOLTAGE TOLERANCE Note.3 +3,-2% 6.0% +3,-2% +8,-4% LINE REGULATION 0.5% 1.0% 0.5% 1.0% LOAD REGULATION 1.5% 2.0% 1.5% 2.0% 200ms, 15ms/230VAC HOLD UP TIME (Typ.) 70ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC 0.7 A/230VAC COLD START 60A/230VAC 30A/115VAC 200ms, 15ms/115VAC at full load 14ms/115VAC at full load 127 ~ 370VDC 82% LEAKAGE CURRENT For earth <200uA/264VAC, For patient <100uA/264VAC OVERLOAD 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +65 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A MTBF 677.8Khrs min. MIL-HDBK-217F (25 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT DIMENSION PACKING NOTE 80mVp-p SETUP, RISE TIME WORKING TEMP. WORKING HUMIDITY OTHERS 58.85W Note.4 53.9W OVER VOLTAGE (Note 5) 53.5W RIPPLE & NOISE (max.) Note.2 80mVp-p PROTECTION EMC RPD-60B OUTPUT NUMBER ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Heat Sink HS1,HS2 can not be shorted. File Name:RPD-60-SPEC 2012-01-09 RPD-60 60W Dual Output Medical Type Mechanical Specification series Unit:mm 101.6 3.175 95.25 50.8 44.45 FS1 CN1 3.175 AC FUSE T2.5/250V 3 2 1 HS2 1 2 3 4 5 6 FS2 AC FUSE T2.5/250V CN2 HS1 3.3 3 max. 29 4- DC Output Connector (CN2) : JST B6P-VH or equivalent AC Input Connector (CN1) : JST B3P-VH or equivalent Assignment AC/N No Pin AC/L Pin No. 1 2 3 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1,2 3,4 5 6 HS1,HS2 can not be shorted Assignment V1 COM V2 NC Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Block Diagram fosc : 100KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING RECTIFIERS & FILTER V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 65 70 (HORIZONTAL) 60 50 40 90 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RPD-60-SPEC 2012-01-09