RPS-75 75W Single Output Medical Type series Features : Universal AC input/Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Free air convection for rated power and 23.5CFM forced air convection for peak load ANSI/AAMI ES60601-1/IEC60601-1/EN60601-1 medical safety approved No load power consumption<0.75W Fixed switching frequency at 65KHz 3 years warranty SPECIFICATION MODEL OUTPUT RPS-75-3.3 RPS-75-5 RPS-75-12 RPS-75-15 RPS-75-24 RPS-75-36 DC VOLTAGE 3.3V 5V 12V 15V 24V 36V 48V RATED CURRENT 15A 14A 6.3A 5A 3.2A 2.1A 1.6A CURRENT RANGE 0 ~ 20A 0 ~ 18.7A 0 ~ 8.3A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 2.8A 0 ~ 2.1A RATED POWER 49.5W 70W 75.6W 75W 76.8W 75.6W 76.8W PEAK LOAD (23.5CFM) 66W 93.5W 99.6W 100.5W 100.8W 100.8W 100.8W 80mVp-p 120mVp-p 150mVp-p 240mVp-p 300mVp-p 300mVp-p 4.75 ~ 5.5V 11.4 ~ 13.2V 13.5 ~ 16.5V 22.8 ~ 27.6V 34.2 ~ 39.6V 45.6 ~ 52.8V RIPPLE & NOISE (max.) Note.2 80mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1.5% 1.5% 1.0% 1.0% 1.0% 1.0% 1.0% 86% 86% 41.4 ~ 48.6V 55.2 ~ 64.8V LOAD REGULATION INPUT SETUP, RISE TIME 500ms, 30ms/230VAC HOLD UP TIME (Typ.) 80ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz 20ms/115VAC at full load 127 ~370VDC 73% 78% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.5A/115VAC 1A/230VAC LEAKAGE CURRENT Earth leakage current <200uA / 264VAC, Patient leakage current <100uA/264VAC OVERLOAD 140 ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed. OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION COLD START 25A/115VAC 3.8 ~ 4.46V 5.75 ~ 6.75V 83% 82% 85% 50A/230VAC 13.8 ~ 16.2V 17.25 ~ 20.25V 27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power to recover -20 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011 (CISPR11), EN55022 (CISPR22) Class B, EN61000-3-2,-3 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61000-6-2, EN61204-3, heavy industry level, EN61204-3 medical level, criteria A MTBF 446.8K hrs min. MIL-HDBK-217F (25 127*76.2*31mm (L*W*H) 0.26Kg; 63pcs/16.3Kg/1.35CUFT DIMENSION PACKING NOTE 500ms, 30ms/115VAC at full load EFFICIENCY(Typ.) PROTECTION OTHERS 2.9 ~ 3.6V RPS-75-48 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. Heat Sink HS1,HS2,HS3 can not be shorted. File Name:RPS-75-SPEC 2012-02-20 RPS-75 75W Single Output Medical Type Mechanical Specification series Unit:mm FAN 5.7 15cm 23.5CFM min. HS3 CN2 3 2 1 64.75 76.2 1 2 3 4 5 6 7 8 1 CN3 2 HS1 CN1 HS2 AC FUSE T2.5/250V AC Input Connector (CN1) : JST B3P-VH or equivalent Pin No. 1 2 3 Assignment AC/N No Pin AC/L Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN2) : JST B8P-VH or equivalent FS2 FS1 4115.8 5.6 Pin No. 1,2,3,4 5,6,7,8 3.8 127 Assignment +V -V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Remote Sense(CN3) : JST B2B-XH or equivalent 31 Pin No. 1 2 Assignment RS+ RS- Mating Housing Terminal JST XHP or equivalent JST SXH-001T-P0.6 or equivalent 3max. HS1,HS2,HS3 can not be shorted Block Diagram fosc : 65KHz +S RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING +V -V -S DETECTION CIRCUIT FG O.L.P. CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 133 23.5CFM Forced air Cooling 90 Others 100 80 Convection Cooling 70 3.3V,5V LOAD (%) LOAD (%) 80 50 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RPS-75-SPEC 2012-02-20