5W Open Frame Medical Power Supply MP05 series Features: Universal AC input / Full range Medical safety approval: ANSI / AAMI ES 60601-1 / TUV EN 60601-1: 2006; IEC 60601-1 / 2xMOPP Isolation class Ⅱ Green design, No-load power consumption < 0.3W Protection: Short circuit, Over load, Over voltage Brown-out (Low AC Input Voltage) High operation temperature up to 70°C Withstand 2G vibration test 3 years warranty MEDICAL MODEL Output Input DC Voltage Range Rated Current Current Range Rated Power Ripple & Noise (Max.) Voltage Adj. Range Voltage Tolerance Line Regulation Load Regulation Setup, Rise Time Hold Up Time Voltage Range Frequency Range Efficiency (Typ.) at 230VAC AC Current (Typ.) Inrush Current (Typ.) Over Load Protection Over Voltage Environment Working Temp. Working Humidity Storage Temp. & Humidity Temp. Coefficient Vibration Safety Standards Safety & EMC Others Note Withstand Voltage Isolation Resistance EMI Conduction & Radiation Harmonic Current EMS Immunity MTBF Dimension (WxHxD) Packing MP05-05 MP05-12 E324816 MP05-15 MP05-24 5V 15V 12V 24V 0.33A 0.42A 0.21A 1A 0 ~ 0.33A 0 ~ 1A 0 ~ 0.42A 0 ~ 0.21A 5W 5.04W 4.95W 5.04W 100mVp-p 150mVp-p 150mVp-p 240mVp-p ±10% ±2% ±1% ±1% ±1% ±0.5% ±0.5% ±0.5% ±0.5% ±1% ±0.5% ±0.5% ±0.5% 100ms, 25ms / 230VAC, 100ms, 25ms / 115VAC at full load 100ms / 230VAC, 25ms / 115VAC at full load 85 ~ 264VAC, 125 ~ 373VDC 47 ~ 63Hz 71% 75% 75% 77% 0.13A / 115VAC, 0.08A / 230VAC Cold Start 25A / 115VAC, 45A / 230VAC Above 110% rated output power Protection type: Hiccup mode, recovers automatically after fault condition is removed 115 ~ 145% rated output voltage Protection type: latch-off mode -20 ~ 70°C (Refer to de-rating curve) 20 ~ 90% RH non-condensing -40 ~ +85°C, 10 ~ 95% RH ±0.03% / °C (0 ~ 50°C) 10 ~ 500Hz, 2G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Certified UL / cUL (ANSI / AAMI ES 60601-1; CAN / CSA-C22.2 No.60601-1); NFPA 99 Certified TUV (EN 60601-1; IEC 60601-1); MOPP approval I/P-O/P: 4KVAC I/P-O/P: 100M Ohms / 500VDC Certified EN 55011 Certified EN 61000-3-2; EN 61000-3-3 Certified EN 60601-1-2; IEC 61000-4-2, 3, 4, 5, 6, 8, 11 217.4K HRS Certified MIL-HDBK-217F 45x19.1x57.9 mm / 1.771x0.752x2.2798 inch 0.033kg; 144pcs / 5.75kg / 1.43CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 3. Tolerance: includes setup time tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of setup time is measured at first cold start. Turning ON/OFF the power supply continuously may increase the setup time. REV. B5 14/04/23 1 MP05 series 5W Open Frame Medical Power Supply Mechanical Drawings: 19.1 [0.752] Unit : mm[inch] 4.5 [0.177] 3.5 [0.138] 1.8 [0.070] 1.05 [0.041] DC OUTPUT 20.04 [0.789] +V AC/N AC/L 5 [0.196] -V 12.47 [0.490] C2 17.5 [0.689] 45 [1.771] AC INPUT 5.33 [0.209] 47 [1.8504] 57.9 [2.279] Block Diagram: RECTIFIERS & FILTER EMI FILTER I/P RECTIFIERS & FILTER POWER SWITCHING PWM CONTROL +V -V DETECTION CIRCUIT De-rating Curve: Load V.S Temp. Load V.S I/P Voltage Ta=25°C 100 100 90 Load (%) Load (%) 80 60 80 70 60 40 50 20 -20 40 0 10 20 30 40 50 Ambient Temperature (°C) 60 70 90 100 110 120 264Vac Input Voltage REV. B5 14/04/23 2