R P T- 6 0 60W Triple Output Medical Type series Features : 4"x2" miniature size Universal AC input / Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Cooling by free air convection UL60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved Fixed switch frequency at 100KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT INPUT CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 12V -5V 5V 12V -12V 5V 15V -15V RATED CURRENT 4A 2A 0.5A 4A 2A 0.5A 4A 1.5A 0.5A CURRENT RANGE 0.5 ~ 4.4A 0.1 ~ 2.2A 0.1 ~ 0.55A 0.5 ~ 4.4A 0.1 ~ 2.2A 0.1 ~ 0.55A 0.5 ~ 4.4A 0.1 ~ 1.65A 0.1 ~ 0.55A RATED POWER 46.5W 100mVp-p 150mVp-p PEAK LOAD(10sec.) 80mVp-p 80mVp-p 80mVp-p VOLTAGE TOLERANCE Note.3 +3,-2% 6.0% +9,-8% LINE REGULATION 0.5% 1.0% LOAD REGULATION 1.5% 2.0% 55W 80mVp-p 100mVp-p 80mVp-p +3,-2% 6.0% +10,-6% +3,-2% 6.0% 8.0% 1.0% 0.5% 1.0% 2.0% 0.5% 2.0% 2.0% +5,-7% 1.5% 2.0% 5.0% 1.5% 3.0% 4.0% SETUP, RISE TIME 200ms, 15ms/230VAC HOLD UP TIME (Typ.) 70ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 77% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC COLD START 60A/230VAC LEAKAGE CURRENT For earth <200uA/264VAC, For patient <100uA/264VAC OVERLOAD 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE 200ms, 15ms/115VAC at full load 15ms/115VAC at full load 127 ~ 370VDC 78% 79% 0.7A/230VAC 30A/115VAC Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +65 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A EMS IMMUNITY MTBF 677.8Khrs min. DIMENSION 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT PACKING NOTE 50W 55W Note.4 51.15W WORKING TEMP. OTHERS 50W RIPPLE & NOISE (max.) Note.2 80mVp-p OVER VOLTAGE (Note 5) RPT-60C CH1 PROTECTION EMC RPT-60B RPT-60A OUTPUT NUMBER MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Heat Sink HS1,HS2 can not be shorted. File Name:RPT-60-SPEC 2011-03-31 R P T- 6 0 60W Triple Output Medical Type series Features : 4"x2" miniature size Universal AC input / Full range Low leakage current<200uA Protections: Short circuit / Overload / Over voltage Cooling by free air convection UL60601-1/IEC60601-1/EN60601-1 medical safety approved UL60950-1/IEC60950-1/EN60950-1 ITE safety approved Fixed switch frequency at 100KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT INPUT CH1 CH2 CH3 CH1 CH2 CH3 DC VOLTAGE 5V 24V 12V 3.3V 5V 12V RATED CURRENT 3.5A 1A 0.5A 5A 3A 0.7A CURRENT RANGE 0.5 ~ 3.85A 0.1 ~ 1.1A 0.1 ~ 0.55A 0.5 ~ 5.5A 0.3 ~ 3.3A 0.1 ~ 0.77A RATED POWER 47.5W PEAK LOAD(10sec.) 80mVp-p 80mVp-p VOLTAGE TOLERANCE Note.3 +3,-2% 6.0% 8.0% +3,-2% 8.0% +10,-6% LINE REGULATION 0.5% 2.0% 2.0% 0.5% 1.0% 2.0% LOAD REGULATION 1.5% 3.0% 4.0% 1.5% 2.0% +5.5,-5% 80mVp-p 80mVp-p 200ms, 15ms/230VAC HOLD UP TIME (Typ.) 70ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 79% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.1A/115VAC COLD START 60A/230VAC LEAKAGE CURRENT For earth <200uA/264VAC, For patient <100uA/264VAC OVERLOAD 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE CH1: 5.75 ~ 6.75V Protection type : Shut down o/p voltage, re-power on to recover -20 ~ +65 200ms, 15ms/115VAC at full load 15ms/115VAC at full load 127 ~ 370VDC 75% 0.7A/230VAC 30A/115VAC CH1: 3.8 ~ 4.45V (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 45 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, UL60601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55011(CISPR11),EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN60601-1-2, EN61204-3, medical level, criteria A EMS IMMUNITY MTBF 677.8Khrs min. DIMENSION 101.6*50.8*29mm (L*W*H) 0.15Kg; 96pcs/15.4Kg/0.89CUFT PACKING NOTE 150mVp-p SETUP, RISE TIME WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE OTHERS 43.9W Note.4 52.25W WORKING TEMP. (Note 5) 39.9W RIPPLE & NOISE (max.) Note.2 80mVp-p PROTECTION EMC RPT-6003 RPT-60D OUTPUT NUMBER MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. Heat Sink HS1,HS2 can not be shorted. File Name:RPT-60-SPEC 2011-03-31 R P T- 6 0 60W Triple Output Medical Type Mechanical Specification series Unit:mm 101.6 3.175 95.25 50.8 44.45 FS1 3.175 AC FUSE T2.5/250V 3 2 1 CN1 HS2 1 2 3 4 5 6 FS2 AC FUSE T2.5/250V CN2 HS1 3.3 3 max. 29 4- DC Output Connector (CN2) : JST B6P-VH or equivalent AC Input Connector (CN1) : JST B3P-VH or equivalent Assignment AC/N No Pin AC/L Pin No. 1 2 3 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Pin No. 1,2 3,4 5 6 HS1,HS2 can not be shorted Assignment V1 COM V2 V3 Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Block Diagram RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING V3 RECTIFIERS & FILTER +V2 RECTIFIERS & FILTER +V1 COM DETECTION CIRCUIT FG O.L.P. fosc : 100KHz RECTIFIERS & FILTER CONTROL O.V.P. Derating Curve Output Derating VS Input Voltage Ta=25 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -20 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 65 70 (HORIZONTAL) 60 50 40 90 95 100 115 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz File Name:RPT-60-SPEC 2011-03-31