3M Housings CH Series For Cartridge Filters The CH housings are constructed from 316 L or 304 stainless steel and manufactured in accordance to design and construction code EN13445 Group 3. They have a maximum pressure rating design of 10 bar g and can be used in temperatures up to 90 ºC. The CH housings are fully CE marked in accordance with the European Pressure Equipment Directive (PED) and are available in a variety of sizes to accommodate from 3 to 116 cartridges (from 3 EQSL to 464 EQSL). Supplied as standard with all internal parts necessary for operation using Double Open Ended (DOE) cartridges, they can be readily converted to take Single Open Ended (SOE) cartridges by using alternative internal components that can be ordered separately. Pressure Equipment Directive 97/23/CE CH vessels are built to PED 97/23/CE Category 3.3 “Sound Engineering Practice” as standard. The vessel designs have been developed so that they can be manufactured for the highest demanding applications - Group 1 (Hazardous Gas) - upon request from existing and known production documentation. All dimensions remain as shown here. ATEX Directive 94/9/CE CH housings are approved for use in ATEX condition II-2-G/D-T5. The user of these housings must ensure that they are used in accordance with the requirements of these PED and ATEX directives at all times. Please consult your local 3M Purification representative for any other classification, other details for PED coded applications or further information. Table 1 : Standard Housing Specifications Features & Benefits 316L and 304 stainless steel construction • Provides excellent corrosion protection for rugged, long-lasting service. Optimum quality standards at competitive costs • Ensure the most appropriate housing is available at the right price. Closure 316L (1.4404) or 304 (1.4306) Stainless Steel Pickle passivated or Glass bead blasted Bolted 08 CH / 12 CH / 19 CH / 22 CH / 27 CH / 30 CH / 40 CH / 55 CH / 80 CH / 116 CH 316L (1.4404) or 304 (1.4306) Stainless Steel Pickle passivated or Glass bead blasted Bolted Housing Orientation Vertical Vertical Standard Gasket Material Nitrile (others on request) Nitrile (others on request) Industrial Cartridges Height 1, 2, 3 and 4 high 3 and 4 high Chemical from 24 to 464 Commercial Food & Beverage Housing Type Specifications Housing Material (in contact) Surface Finish 03 CH / 04 CH / 05 CH Number of Cartridges (EQSL) from 3 to 20 Connection Sizes ISO flat faced flange ISO flat faced flange Vent Connection see table 2 see table 2 and 4 Drain Connection see table 2 see table 2 and 4 Max. Operating Pressure 10 bar g 10 bar g Max. Operating Temperature 90 °C 90 °C PED 97/23/CE Article 3.3 Article 3.3 ATEX 94/9/CE II-2-G/D-T5 II-2-G/D-T5 This table is intended as a guide. Swing bolt design • Optimizes cartridge change-out. Applications Table 2 : Other Specifications Housings 03 CH to 12 CH Housing Type Inlet/Outlet Vent Drain Bolts Volume Weight 03 CHB 1 DN 50 G ¼” B R ½” 3 x M16 18 L 30 Kg 03 CHB 2 DN 50 G ¼” B R ½” 3 x M16 27 L 35 Kg 03 CHB 3 DN 50 G ¼” B R ½” 3 x M16 36 L 40 Kg 03 CHB 4 DN 50 G ¼” B R ½” 3 x M16 45 L 45 Kg 04 CHB 1 DN 50 G ¼” B R ½” 3 x M16 18 L 30 Kg 04 CHB 2 DN 50 G ¼” B R ½” 3 x M16 27 L 35 Kg 04 CHB 3 DN 50 G ¼” B R ½” 3 x M16 36 L 40 Kg 04 CHB 4 DN 50 G ¼” B R ½” 3 x M16 45 L 45 Kg 05 CHB 1 DN 50 G ¼” B R ½” 3 x M16 18 L 30 Kg 05 CHB 2 DN 50 G ¼” B R ½” 3 x M16 27 L 35 Kg 05 CHB 3 DN 50 G ¼” B R ½” 3 x M16 36 L 40 Kg 05 CHB 4 DN 50 G ¼” B R ½” 3 x M16 45 L 45 Kg 08 CHB 3 DN 80 G ½” B R ¾” 6 x M16 57 L 65 Kg 08 CHB 4 DN 80 G ½” B R ¾” 6 x M16 70 L 70 Kg 12 CHB 3 DN 100 G ½” B R ¾” 8 x M16 81 L 90 Kg 12 CHB 4 DN 100 G ½” B R ¾” 8 x M16 101 L 100 Kg Table 3 : Dimensions Housings 03 CH to 12 CH (in mm) 2 Housing Type A Vent to Inlet B Inlet to Outlet C Drain to Outlet D Diameter E Top to Outlet F distance for change out X 03 CHB 1 200 250 200 219 615 900 278 03 CHB 2 200 250 200 219 865 1400 278 03 CHB 3 200 250 200 219 1115 1900 278 03 CHB 4 200 250 200 219 1365 2400 278 04 CHB 1 200 250 200 219 615 900 278 04 CHB 2 200 250 200 219 865 1400 278 04 CHB 3 200 250 200 219 1115 1900 278 04 CHB 4 200 250 200 219 1365 2400 278 05 CHB 1 200 250 200 219 615 900 278 05 CHB 2 200 250 200 219 865 1400 278 05 CHB 3 200 250 200 219 1115 1900 278 05 CHB 4 200 250 200 219 1365 2400 278 08 CHB 3 250 300 250 273 1150 1900 332 08 CHB 4 250 300 250 273 1400 2400 332 12 CHB 3 300 350 290 324 1200 2000 383 12 CHB 4 300 350 290 324 1450 2500 383 3M Housings CH Series For Cartridge Filters Table 4 : Other Specifications Housings 19 CH to 116 CH Housing Type Inlet/Outlet Vent Drain Bolts Volume Weight 19 CHB 3 DN 150 Rp ½” R 1” ½ 8 x M20 132 L 156 Kg 19 CHB 4 DN 150 Rp ½” R 1” ½ 8 x M20 162 L 166 Kg 22 CHB 3 DN 150 Rp ½” R 1” ½ 8 x M20 172 L 176 Kg 22 CHB 4 DN 150 Rp ½” R 1” ½ 8 x M20 210 L 188 Kg 27 CHB 3 DN 150 Rp ½” R 1” ½ 8 x M20 172 L 176 Kg 27 CHB 4 DN 150 Rp ½” R 1” ½ 8 x M20 210 L 188 Kg 30 CHB 3 DN 200 Rp ½” R 1” ½ 10 x M20 216 L 233 Kg 30 CHB 4 DN 200 Rp ½” R 1” ½ 10 x M20 263 L 249 Kg 40 CHB 3 DN 200 Rp ¾” R 2” 10 x M24 316 L 368 Kg 40 CHB 4 DN 200 Rp ¾” R 2” 10 x M24 384 L 387 Kg 55 CHB 3 DN 250 Rp ¾” R 2” 12 x M27 441 L 500 Kg 55 CHB 4 DN 250 Rp ¾” R 2” 12 x M27 534 L 527 Kg 80 CHB 3 DN 250 Rp 1” R 2” 12 x M24 695 L 540 Kg 80 CHB 4 DN 250 Rp 1” R 2” 12 x M24 818 L 567 Kg 116 CHB 3 DN 300 Rp 1” R 2” 16 x M24 836 L 775 Kg 116 CHB 4 DN 300 Rp 1” R 2” 16 x M24 1009 L 805 Kg Table 5 : Dimensions Housings 19 CH to 116 CH (in mm) Housing Type A Middle to Inlet B Inlet to Outlet C Drain to Outlet D E Diameter Outlet to Bottom F Top to Outlet G distance for change out X 19 CHB 3 300 400 280 400 400 1530 2340 530 19 CHB 4 300 400 280 400 400 1780 2800 530 22 CHB 3 350 450 330 450 400 1570 2330 580 22 CHB 4 350 450 330 450 400 1820 2840 580 27 CHB 3 350 450 330 450 400 1570 2330 580 27 CHB 4 350 450 330 450 400 1820 2840 580 30 CHB 3 400 470 330 500 400 1580 2340 630 30 CHB 4 400 470 330 500 400 1830 2850 630 40 CHB 3 450 550 390 600 450 1760 2520 770 40 CHB 4 450 550 390 600 450 2010 3030 770 55 CHB 3 550 600 440 700 450 1800 2560 870 55 CHB 4 550 600 440 700 450 2050 3070 870 80 CHB 3 550 600 440 800 450 1810 2570 970 80 CHB 4 550 600 440 800 450 2060 3080 970 116 CHB 3 650 700 495 950 550 1860 2620 1120 116 CHB 4 650 700 495 950 550 2110 3130 1120 3 3M Housings CH Series For Cartridge Filters Ordering Guide CH Range Number of Cartridges Housing Type Closure Type Cartridge Height Housing Orientation Material of Construction 03 04 05 CH B = Bolted 1 2 3 4 V = Vertical 08 12 19 22 27 30 40 55 80 116 CH B = Bolted 3 4 V = Vertical Gasket Surface Finish Connection Outlet Orientation 4 = 304 St. St. 6 = 316L St. St. NB = Nitrile F0 = Pickle Passivated or Glass Bead Blasted BP = ISO Flat Faced Flange DN = Downwards 4 = 304 St. St. 6 = 316L St. St. NB = Nitrile F0 = Pickle Passivated or Glass Bead Blasted BP = ISO Flat Faced Flange DN = Downwards Important Notice 3M Purification MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Since a variety of factors can affect the use and performance of a 3M Purification product in a particular application, some of which are uniquely within the user’s knowledge and control, user is responsible for determining whether or not the 3M Purification product is fit for a particular purpose and suitable for user’s method of application. Limitation of Remedies and Liability If the 3M Purification product is proved to be defective, THE EXCLUSIVE REMEDY, AT 3M PURIFICATION’S OPTION, SHALL BE TO REFUND THE PURCHASE PRICE OR TO REPAIR OR REPLACE THE DEFECTIVE PRODUCT. 3M shall not otherwise be liable for loss or damages, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including, but not limited to, contract, negligence, warranty or strict liability. WARRANTY Seller warrants its equipment against defects in workmanship and material for a period of 12 months from date of shipment from the factory under normal use and service and otherwise when such equipment is used in accordance with instructions furnished by Seller and for purposes disclosed in writing at the time of purchase, if any. Any unauthorized alteration or modification of the equipment by Buyer will void this warranty. Seller’s liability under this warranty shall be limited to the replacement or repair, F.O.B. point of manufacture, of any defective equipment or part which, having been returned to the factory, transportation charges prepaid, has been inspected and determined by the Seller to be defective. THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EITHER EXPRESSED OR IMPLIED, AS TO DESCRIPTION, QUALITY, MERCHANTABILITY, FITNESS FOR ANY PAR TICULAR PURPOSE OR USE, OR ANY OTHER MATTER. Under no circumstances shall Seller be liable to Buyer or any third party for any loss of profits or other direct or indirect costs, expenses, losses or consequential damages arising out of or as a result of any defects in or failure of its products or any part or parts thereof or arising out of or as a result of parts or components incorporated in Seller’s equipment but not supplied by the Seller. 3M United Kingdom plc 3M Ireland 3M Purification 3M Centre, Cain Road Bracknell, RG12 8HT United Kingdom Tel.: 0845 602 5237 Fax: +44 (0)1344 858559 E-mail: [email protected] 3M Purification The Iveagh Building, The Park, Carrickmines, Dublin 18 Republic of Ireland Tel.: 1800 320 500 Fax: +353 (0)1 280 3555 For more contact addresses visit our website www.3m.eu/filtration or www.3mpurification.com/international. Data may be subject to change without further notice. © 3M 2010. All rights reserved. DOC10002 LITHSCH1.E - 0510