3M™ CH Housings

3M Housings
CH Series
For Cartridge Filters
The CH housings are constructed from 316 L or 304 stainless steel and
manufactured in accordance to design and construction code EN13445 Group
3. They have a maximum pressure rating design of 10 bar g and can be used in
temperatures up to 90 ºC.
The CH housings are fully CE marked in accordance with the European
Pressure Equipment Directive (PED) and are available in a variety of sizes to
accommodate from 3 to 116 cartridges (from 3 EQSL to 464 EQSL).
Supplied as standard with all internal parts necessary for operation using Double
Open Ended (DOE) cartridges, they can be readily converted to take Single Open
Ended (SOE) cartridges by using alternative internal components that can be ordered
separately.
Pressure Equipment Directive 97/23/CE
CH vessels are built to PED 97/23/CE Category 3.3 “Sound Engineering Practice” as
standard. The vessel designs have been developed so that they can be manufactured
for the highest demanding applications - Group 1 (Hazardous Gas) - upon request
from existing and known production documentation. All dimensions remain as shown
here.
ATEX Directive 94/9/CE
CH housings are approved for use in ATEX condition II-2-G/D-T5.
The user of these housings must ensure that they are used in accordance with the
requirements of these PED and ATEX directives at all times. Please consult your local
3M Purification representative for any other classification, other details for PED coded
applications or further information.
Table 1 : Standard Housing Specifications
Features & Benefits
316L and 304 stainless steel construction
• Provides excellent corrosion protection for
rugged, long-lasting service.
Optimum quality standards at competitive costs
• Ensure the most appropriate housing is available
at the right price.
Closure
316L (1.4404) or 304 (1.4306)
Stainless Steel
Pickle passivated or
Glass bead blasted
Bolted
08 CH / 12 CH / 19 CH / 22 CH /
27 CH / 30 CH / 40 CH / 55 CH /
80 CH / 116 CH
316L (1.4404) or 304 (1.4306)
Stainless Steel
Pickle passivated or
Glass bead blasted
Bolted
Housing Orientation
Vertical
Vertical
Standard Gasket Material
Nitrile (others on request)
Nitrile (others on request)
Industrial
Cartridges Height
1, 2, 3 and 4 high
3 and 4 high
Chemical
from 24 to 464
Commercial
Food & Beverage
Housing Type Specifications
Housing Material (in contact)
Surface Finish
03 CH / 04 CH / 05 CH
Number of Cartridges (EQSL) from 3 to 20
Connection Sizes
ISO flat faced flange
ISO flat faced flange
Vent Connection
see table 2
see table 2 and 4
Drain Connection
see table 2
see table 2 and 4
Max. Operating Pressure
10 bar g
10 bar g
Max. Operating Temperature
90 °C
90 °C
PED 97/23/CE
Article 3.3
Article 3.3
ATEX 94/9/CE
II-2-G/D-T5
II-2-G/D-T5
This table is intended as a guide.
Swing bolt design
• Optimizes cartridge change-out.
Applications
Table 2 : Other Specifications Housings 03 CH to 12 CH
Housing Type
Inlet/Outlet
Vent
Drain
Bolts
Volume
Weight
03 CHB 1
DN 50
G ¼” B
R ½”
3 x M16
18 L
30 Kg
03 CHB 2
DN 50
G ¼” B
R ½”
3 x M16
27 L
35 Kg
03 CHB 3
DN 50
G ¼” B
R ½”
3 x M16
36 L
40 Kg
03 CHB 4
DN 50
G ¼” B
R ½”
3 x M16
45 L
45 Kg
04 CHB 1
DN 50
G ¼” B
R ½”
3 x M16
18 L
30 Kg
04 CHB 2
DN 50
G ¼” B
R ½”
3 x M16
27 L
35 Kg
04 CHB 3
DN 50
G ¼” B
R ½”
3 x M16
36 L
40 Kg
04 CHB 4
DN 50
G ¼” B
R ½”
3 x M16
45 L
45 Kg
05 CHB 1
DN 50
G ¼” B
R ½”
3 x M16
18 L
30 Kg
05 CHB 2
DN 50
G ¼” B
R ½”
3 x M16
27 L
35 Kg
05 CHB 3
DN 50
G ¼” B
R ½”
3 x M16
36 L
40 Kg
05 CHB 4
DN 50
G ¼” B
R ½”
3 x M16
45 L
45 Kg
08 CHB 3
DN 80
G ½” B
R ¾”
6 x M16
57 L
65 Kg
08 CHB 4
DN 80
G ½” B
R ¾”
6 x M16
70 L
70 Kg
12 CHB 3
DN 100
G ½” B
R ¾”
8 x M16
81 L
90 Kg
12 CHB 4
DN 100
G ½” B
R ¾”
8 x M16
101 L
100 Kg
Table 3 : Dimensions Housings 03 CH to 12 CH (in mm)
2
Housing Type A
Vent to
Inlet
B
Inlet to
Outlet
C
Drain to
Outlet
D
Diameter
E
Top to
Outlet
F
distance for
change out
X
03 CHB 1
200
250
200
219
615
900
278
03 CHB 2
200
250
200
219
865
1400
278
03 CHB 3
200
250
200
219
1115
1900
278
03 CHB 4
200
250
200
219
1365
2400
278
04 CHB 1
200
250
200
219
615
900
278
04 CHB 2
200
250
200
219
865
1400
278
04 CHB 3
200
250
200
219
1115
1900
278
04 CHB 4
200
250
200
219
1365
2400
278
05 CHB 1
200
250
200
219
615
900
278
05 CHB 2
200
250
200
219
865
1400
278
05 CHB 3
200
250
200
219
1115
1900
278
05 CHB 4
200
250
200
219
1365
2400
278
08 CHB 3
250
300
250
273
1150
1900
332
08 CHB 4
250
300
250
273
1400
2400
332
12 CHB 3
300
350
290
324
1200
2000
383
12 CHB 4
300
350
290
324
1450
2500
383
3M Housings
CH Series
For Cartridge Filters
Table 4 : Other Specifications Housings 19 CH to 116 CH
Housing Type
Inlet/Outlet
Vent
Drain
Bolts
Volume
Weight
19 CHB 3
DN 150
Rp ½”
R 1” ½
8 x M20
132 L
156 Kg
19 CHB 4
DN 150
Rp ½”
R 1” ½
8 x M20
162 L
166 Kg
22 CHB 3
DN 150
Rp ½”
R 1” ½
8 x M20
172 L
176 Kg
22 CHB 4
DN 150
Rp ½”
R 1” ½
8 x M20
210 L
188 Kg
27 CHB 3
DN 150
Rp ½”
R 1” ½
8 x M20
172 L
176 Kg
27 CHB 4
DN 150
Rp ½”
R 1” ½
8 x M20
210 L
188 Kg
30 CHB 3
DN 200
Rp ½”
R 1” ½
10 x M20
216 L
233 Kg
30 CHB 4
DN 200
Rp ½”
R 1” ½
10 x M20
263 L
249 Kg
40 CHB 3
DN 200
Rp ¾”
R 2”
10 x M24
316 L
368 Kg
40 CHB 4
DN 200
Rp ¾”
R 2”
10 x M24
384 L
387 Kg
55 CHB 3
DN 250
Rp ¾”
R 2”
12 x M27
441 L
500 Kg
55 CHB 4
DN 250
Rp ¾”
R 2”
12 x M27
534 L
527 Kg
80 CHB 3
DN 250
Rp 1”
R 2”
12 x M24
695 L
540 Kg
80 CHB 4
DN 250
Rp 1”
R 2”
12 x M24
818 L
567 Kg
116 CHB 3
DN 300
Rp 1”
R 2”
16 x M24
836 L
775 Kg
116 CHB 4
DN 300
Rp 1”
R 2”
16 x M24
1009 L
805 Kg
Table 5 : Dimensions Housings 19 CH to 116 CH (in mm)
Housing
Type
A
Middle
to Inlet
B
Inlet to
Outlet
C
Drain to
Outlet
D
E
Diameter Outlet to
Bottom
F
Top to
Outlet
G
distance for
change out
X
19 CHB 3
300
400
280
400
400
1530
2340
530
19 CHB 4
300
400
280
400
400
1780
2800
530
22 CHB 3
350
450
330
450
400
1570
2330
580
22 CHB 4
350
450
330
450
400
1820
2840
580
27 CHB 3
350
450
330
450
400
1570
2330
580
27 CHB 4
350
450
330
450
400
1820
2840
580
30 CHB 3
400
470
330
500
400
1580
2340
630
30 CHB 4
400
470
330
500
400
1830
2850
630
40 CHB 3
450
550
390
600
450
1760
2520
770
40 CHB 4
450
550
390
600
450
2010
3030
770
55 CHB 3
550
600
440
700
450
1800
2560
870
55 CHB 4
550
600
440
700
450
2050
3070
870
80 CHB 3
550
600
440
800
450
1810
2570
970
80 CHB 4
550
600
440
800
450
2060
3080
970
116 CHB 3
650
700
495
950
550
1860
2620
1120
116 CHB 4
650
700
495
950
550
2110
3130
1120
3
3M Housings
CH Series
For Cartridge Filters
Ordering Guide CH Range
Number of
Cartridges
Housing
Type
Closure
Type
Cartridge
Height
Housing
Orientation
Material of
Construction
03
04
05
CH
B = Bolted
1
2
3
4
V = Vertical
08
12
19
22
27
30
40
55
80
116
CH
B = Bolted
3
4
V = Vertical
Gasket
Surface Finish
Connection
Outlet
Orientation
4 = 304 St. St.
6 = 316L St. St.
NB = Nitrile
F0
= Pickle
Passivated or
Glass Bead
Blasted
BP
= ISO Flat
Faced Flange
DN
= Downwards
4 = 304 St. St.
6 = 316L St. St.
NB = Nitrile
F0
= Pickle
Passivated or
Glass Bead
Blasted
BP
= ISO Flat
Faced Flange
DN
= Downwards
Important Notice
3M Purification MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Since a variety of factors can affect the
use and performance of a 3M Purification product in a particular application, some of which are uniquely within the user’s knowledge and control, user is responsible for determining whether or not the 3M Purification product is fit for a
particular purpose and suitable for user’s method of application.
Limitation of Remedies and Liability
If the 3M Purification product is proved to be defective, THE EXCLUSIVE REMEDY, AT 3M PURIFICATION’S OPTION, SHALL BE TO REFUND THE PURCHASE PRICE OR TO REPAIR OR REPLACE THE DEFECTIVE PRODUCT. 3M shall not otherwise
be liable for loss or damages, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including, but not limited to, contract, negligence, warranty or strict liability.
WARRANTY
Seller warrants its equipment against defects in workmanship and material for a period of 12 months from date of shipment from the factory under normal use and service and otherwise when such equipment is used in accordance with
instructions furnished by Seller and for purposes disclosed in writing at the time of purchase, if any. Any unauthorized alteration or modification of the equipment by Buyer will void this warranty. Seller’s liability under this warranty shall
be limited to the replacement or repair, F.O.B. point of manufacture, of any defective equipment or part which, having been returned to the factory, transportation charges prepaid, has been inspected and determined by the Seller to be
defective. THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EITHER EXPRESSED OR IMPLIED, AS TO DESCRIPTION, QUALITY, MERCHANTABILITY, FITNESS FOR ANY PAR TICULAR PURPOSE OR USE, OR ANY OTHER MATTER. Under no
circumstances shall Seller be liable to Buyer or any third party for any loss of profits or other direct or indirect costs, expenses, losses or consequential damages arising out of or as a result of any defects in or failure of its products or any
part or parts thereof or arising out of or as a result of parts or components incorporated in Seller’s equipment but not supplied by the Seller.
3M United Kingdom plc
3M Ireland
3M Purification
3M Centre, Cain Road
Bracknell, RG12 8HT
United Kingdom
Tel.: 0845 602 5237
Fax: +44 (0)1344 858559
E-mail: [email protected]
3M Purification
The Iveagh Building, The Park,
Carrickmines, Dublin 18
Republic of Ireland
Tel.: 1800 320 500
Fax: +353 (0)1 280 3555
For more contact addresses visit our website www.3m.eu/filtration or
www.3mpurification.com/international.
Data may be subject to change without further notice.
© 3M 2010. All rights reserved.
DOC10002
LITHSCH1.E - 0510