Board for SKL / SKH

S/GEN/PRES-SKL/B/23/03/2000
page 1 / 4 GB
New concept for SSRs.
SKL
SKH
The SKA standard range for printed circuit board
is extended with products in hybrid technology
( Direct Copper Bonding (*) ) with :
By courtesy of
Aavid Thermalloy
--> 230VAC and 400VAC SKA models built
with 50A back to back thyristors which can drive a 6A permanent current and sustain very high
surge current : 600A/20ms and I2t >1800A2s.
--> SKL range for mounting on heatsink with
16, 25, 50 and 75A power element size . With
these SSRs you can drive loads with high inrush
current. The nominal current is limited by the
size of the heatsink and the printed circuit board
( generally 25/30A).( For example : you can drive a load with a nominal current of 25/30A according to the printed circuit board and the heatsink , but with an inrush current ≥ 75A during
few seconds)
--> SKH range with a small heatsink cliped on
the SKL products . SKH can drive a 10A
permanent current, extended to 25A with
forced air cooling.
10 SKL on a PCB and
cliped on a heatsink
Exemple mounting :
see application note
This range is particularly designed for heater , incandescent lamps and motor control . These
SSRs can sustain very high surge currents ( up to 1000A/10ms and 5000A2s) , therefore they can
easily be protected against short-circuit of the load and can drive loads with high inrush currents.
Many applications like motor switching (pump controls , motor reversing ,SSRs integration inside
the motor connections box,...), transformers, food equipment ( coffee machines , pizza ovens,... ,
lamps ( infrared lamps, traffic lights, lightning, ...), medical equipments , ........
As all celduc SSRs, this range is built with high immunity components in compliance with european standards, with very low zero cross voltage,..........
(*) The first advantage of DCB technology (Direct Copper bonding) is the thermal performances ,
but the main adavantage is the increasing of the lifetime expectancy , mainly on loads with high
inrush currents.

celduc
All technical characteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
r
e
l
a
i
s
S/GEN/PRES-SKL/B/23/03/2000
page 2 / 4 GB
REFERENCE
l =10,2mm
h=25,4mm
standard range
(with or without LED)
L=43,2mm
l =10,2mm
h=25,4mm
I2t (A2s)
Control
Type
R input
protection
72A2s
72A2s
72A2s
72A2s
72A2s
72A2s
72A2s
72A2s
72A2s
-
2,5-10VDC
4-30VDC
4-30VDC
2,5-10VDC
5-30VDC
5-30VDC
4-30VDC
2,5-10VDC
4-30VDC
3-30VDC
3-30VDC
Z.Cross
Z.Cross
random
Z.Cross
Z.Cross
Z.Cross
random
Z.Cross
Z.Cross
-
330Ω
1000Ω
1000Ω
330Ω
1000Ω
1000Ω
1000Ω
330Ω
1000Ω
1000Ω
1000Ω
VDR
VDR
VDR
VDR
VDR
-
Other models : with LED : see SKA and SKB
data-sheets
SKA10420
SKA20420
SKA20421
SKA10440
SKA20440
SKA20460
SKA20461
SKB10420
SKB20420
SKD10306
SKD10120
L=43,2mm
Output
Output
voltage
current
12-275VAC
4A
12-275VAC
4A
12-275VAC
4A
12-460VAC
4A
12-460VAC
4A
24-600VAC
4A
24-600VAC
4A
12-280VAC
4A
12-280VAC
4A
2-60VDC
3A
2-200VDC
1A
REFERENCE
new SKA : hybrid
technology
L=43,2mm l =6,3mm h=25,4mm
Output
Output
I2t (A2s)
voltage
current
SKA10620
12-280VAC
6A
1800A2S
SKA20620
12-280VAC
6A
1800A2S
SKA10640
24-600VAC
6A
1800A2S
SKA20640
24-600VAC
6A
1800A2S
SKA 6A with I2t as SKL range: on request
REFERENCE
new SKL
with external heatsink
L=43,2mm l =21mm h=35,7mm
Output
voltage
Current with
WF032000
heatsink
SKL10120
12-280VAC 15A @ 40°C
SKL20120
12-280VAC 15A @ 40°C
SKL10220
12-280VAC 20A @ 25°C
SKL20220
12-280VAC 20A @ 25°C
SKL10240
24-600VAC 20A @ 35°C
SKL20240
24-600VAC 20A @ 35°C
SKL10520
12-280VAC 27A @ 25°C
SKL20520
12-280VAC 27A @ 25°C
SKL10540
24-600VAC 27A @ 25°C
SKL20540
24-600VAC 27A @ 25°C
SKL10740
24-600VAC 30A @ 20°C
SKL20740
24-600VAC 30A @ 20°C
All models available in Random control
3-30VDC control : SK541100
Control
Type
R input
Protection
4-14VDC
8-32VDC
4-14VDC
8-32VDC
Z.Cross
Z.Cross
Z.Cross
Z.Cross
440Ω
1640Ω
440Ω
1640Ω
-
Thyristors
size
I2t (A2s)
16A
16A
25A
25A
25A
25A
50A
50A
50A
50A
75A
75A
128A2s
128A2s
312A2s
312A2s
450A2s
450A2s
1800A2S
1800A2S
1800A2S
1800A2S
5000A2S
5000A2S
Control
Type
R input
4-14VDC
8-32VDC
4-14VDC
8-32VDC
4-14VDC
8-32VDC
4-14VDC
8-32VDC
4-14VDC
8-32VDC
4-14VDC
8-32VDC
Z.Cross
Z.Cross
Z.Cross
Z.Cross
Z.Cross
Z.Cross
Z.Cross
Z.Cross
Z.Cross
Z.Cross
Z.Cross
Z.Cross
440Ω
1640Ω
440Ω
1640Ω
440Ω
1640Ω
440Ω
1640Ω
440Ω
1640Ω
440Ω
1640Ω
REFERENCE
new SKH
with integrated heatsink
l=30mm
Output
Output
output curI2t
Control
Type
R input
voltage
current
rent with fan (A2s)
SKH10120
12-280VAC 10A @20°C
16A
128
4-14VDC Z.Cross
440Ω
SKH20120
12-280VAC 10A @20°C
16A
128
8-32VDC Z.Cross 1640Ω
SKH10240
24-600VAC 10A @25°C
25A
450
4-14VDC Z.Cross
440Ω
SKH20240
24-600VAC 10A @25°C
25A
450
8-32VDC Z.Cross 1640Ω
The SKH is built with SKL + a clipped heatsink . So all the SKL range can become SKH
SKL
ACCESSOIRIES
Dissipateurs thermiques ( Max Clip System (*) : S507 /Aavid Thermalloy):
WF042000 : L=100mm :≈ 3,6-4 K/W (sans ventilation)
WF032000: L=150mm :≈ 2,6-3 K/W (sans ventilation)
Clips for
WF03/04 :
1L941000
h=51mm
L=100/150mm
* The Max Clip System of Aavid Thermalloy,
Patented Worldwide ( patent N°9805561)

celduc
r
e
l
a
i
clips with screw
: 1L942000
Clip max 23
Aavid Thermalloy
www.celduc.com
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
S/GEN/PRES-SKL/B/23/03/2000
page 3 / 4 GB
Mains Applications :
The standard SKA/SKB/SKD range is mainly adapted for driving
small loads like contactors , electromagnets , lamps,........
resistive loads
lamps
inductive loads
REF
( contactors,...)
SKAxx4xx
Standard SK
range
SKBxx4xx
SKDxxxxx
New SKA in
hybrid technology
4A 230VAC
4A 400VAC
4A 600VAC
4A 230VAC
4A 400VAC
3A 60VDC
1A 200VDC
2,5A 230VAC
2,5A 400VAC
2,5A 600VAC
2,5A 230VAC
2,5A 400VAC
2A 60VDC
0,7A 200VDC
2,5A 230VAC
2,5A 400VAC
2A 60VDC
0,7A 200VDC
This SKA range with high Itsm and I2t is designed to drive loads
with :
--> a protection by Miniature Circuit Breakers : Typical example :
heating control on small molding machines.
--> high inrush current on loads like lamps or motors (ON/OFF or
reversing applications)
REF
resistive loads
( AC-51)
Lamps
( AC-55)
Inductive loads
( AC-53)
SKAxx6xx
6A 230VAC
6A 400VAC
6A 230VAC
6A 400VAC
6A 230VAC
6A 400VAC
Electromagnets , lamps,
contactors,.........
Id =1,4xIn
heater
Id =10xIn
The SKH range with integrated heatsink can drive loads up to 10A:
SKH with integrated
heatsink
SKL for external
heatsink
REF
resistive loads
( AC-51)
Lamps
( AC-55)
Inductive loads
( AC-53)
SKHxx1xx
10A 230VAC
3A 230VAC
3A 230VAC
SKHxx2xx
10A 400VAC
5A 400VAC
5A 400VAC
The large range of SKL is designed to be installed with an external
heatsink allows to reduce the sizes and the price of the equipment,
everywhere , there are many SSRs and electronic control . The limit
is given by the heatsink and the printed circuit board ( generally
25/30A).
The incomparable characteristics of Itsm and I2t in this small size allows to sustain very high surge current on loads like lamps , motors
or transformers.
The short circuit protection on the load can easily be made by Miniature Circuit Breakers.
All the range can be delivered with random control with a turn on time <50µs . These SSRs are adapted to phase angle control on different loads like lamps ,...... and to drive some loads like transformers.
REF
SKLxx1xx
SKLxx2xx
SKLxx5xx
SKLxx7xx
resistive loads
( AC-51)
Lamps
( AC-55)
Inductive loads
( AC-53)
16A 230VAC
5A 230VAC
3A 230VAC
25A 230VAC
25A 400VAC
30A 230VAC
30A 400VAC
30A 230VAC
30A 400VAC
8A 230VAC
8A 400VAC
16A 230VAC
16A 400VAC
25A 230VAC
25A 400VAC
5A 230VAC
5A 400VAC
12A 230VAC
12A 400VAC
16A 230VAC
16A 400VAC
infrared lamps or
lighting lamps
Id =8xIn
Motor
Id =100xIn
Transformer
SKL protected by
MCB
NB : All the range can be delivered on a Rail DIN adapter socket . See XK range.

celduc
r
e
l
a
i
www.celduc.com
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19
S/GEN/PRES-SKL/B/23/03/2000
page 4 / 4 GB
Selector guide by application.
The new SKL/SKH SSRs are designed for mounting on a
printed circuit board. They are specified in :
* Thermal current ( Ie or Ith) depending on the heatsink size.
* Itsm : Maximum surge current into the SSR.
For each reference see curves on the data-sheets.
Use a varistor accross the SSR's output.
In the note below , some exemples are given for different
types of loads.
Ph
Ph
mounting
SK model
VDR on
the PCB
Charge
/ Load
Ou / Or
SSR
SK model
VDR on
the PCB
Charge
/ Load
SSR
N
N
When the load is cold , the starting current can increase at a maximum of 1,4xIn.
In a normal case , with fuses protection ( see application note : SSRs protection) , choose
the SSR in compliance with the nominal current and the starting current.
Generally a SKL on printed circuit board is limited at about 25A due to the PCB and the
connectors.
In case of a protection by MCB , you must use I2t SSRs : 1800 or 5000A2s
heating load
.Exemples :2000W/230VAC : In = 8,7A --> 16A SSR is acceptable : SKH20120
: 6KW with 3 resistors on 3x400VAC line / protection by MCB
--> 9A/phase ==> 3 SKL20540 + 2,6K/W + MCB 16A Z curve
AC-51
infrared lamp
Incandescent lamps ( infrared ,....) : AC-55b have generally inrush currents up to 8 or 10
times the nominal current . You can use the curve Itsm = f(t) , and take a good margin to
have a correct lifetime expectancy.
Exemple : lamp 1500W/230VAC : In = 6,5A --> SKL20520 : 50A rating.
Electric discharge lamp : AC-55a have also high inrush current , but in addition , there
are overvoltage at the turn OFF . ---> Use 400VAC SSRs for 230VAC loads and add a varistor to protect the SSR.
AC-55
motor
AC-53
transformer
AC-56b
others loads
Squirrel cage motors : AC-53 have generally inrush currents up to 5 or 8 times the
nominal current . Standards give 8 x In during 1,6s .
--> Adapt the SSR to the motor nominal current x 8
Exemple : Three phase motor :2,2KW /400VAC
IAC-53 = In = 5A ---> Id = 40A
Use 3 SKL20540 ( one by phase) and 3 VDRs ( 420V size 14)
See application note on transformer control.
Depending on the transformer type , the inrush current can reach 100 x In.
It is better to use random SSRs.
Check the inrush current into the transformer . A good method is to measure the primary
resistor, because when the transformer is satured , the current is near U/r.
With 75A SKL ( repetitive Itsm : 500A/20ms) , it is possible to drive transformers with
very high inrush currents.
In all cases, you must respect the maximum current at turn-ON , the thermal caracteristics
when running and the maximum overvoltage at turn-OFF.
SSRs with 1600Vpeak can be delivered for specific applications like PFC , UPS,............

celduc
r
e
l
a
i
www.celduc.com
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19