Data Sheet

DRA1 SPF Series
• 10mm Single Channel DIN Rail Mount SSR Assembly
• AC Ratings up to 380 VAC and 10 Amps
• 3-15 VDC, 15-32VDC 18-36 VAC and 90-180 VAC control
• Cage style screw terminals for easy connection
• Fits standard 35mm DIN rail
• Includes LED Status indicator (DC control only)
PRODUCT SELECTION
Description
3-15 VDC Control
4-15 VDC Control
15-32 VDC Control
90-140 Vrms Control
18-36 Vrms Control
10 A
10A
DRA1-SPF240D25
DRA1-SPF240D25R (5)
10 A
DRA1-SPFE240D25
DRA1-SPFE240D25R (5)
10 A
DRA1-SPF380D25
DRA1-SPFE380D25
DRA1-SPF240A25
DRA1-SPFE240A25
OUTPUT SPECIFICATIONS (1)
Description
SPF(E)240x25
SPF(E)380x25
12-280
600
10
0.06
0.1
500
239/250
285/260
1.6
48-380**
1200
10
0.06
0.1
500
239/250
285/260
1.6
Operating Voltage [VAC]
Transient Overvoltage [Vpk]
Maximum Load Current [Arms] (2) (3)
Minimum Load Current [Arms]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum off-state dv/dt @ maximum rated voltage [V/µsec] (4)
Maximum 1 Cycle Surge Current (50/60 Hz) [Apk]
Maximum I²t for fusing (50/60 Hz, 1/2 cycle) [A² sec]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Must Turn On Voltage
Must Turn Off Voltage
Typycal Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec] (5)
Maximum Turn-Off Time [µsec]
SPF240D25
SPF380D25
SPFExxxD25
SPFxxxA25
SPFExxxA25
3-15 VDC
3.0 VDC
1 .0 VDC
15 mAdc
300 Ohm
1/2 Cycle
1/2 Cycle
4-15 VDC
4.0 VDC
1 .0 VDC
15 mAdc
240 Ohm
1/2 Cycle
1/2 Cycle
15-32 VDC
15.0 VDC
1 .0 VDC
15 mAdc
1500 Ohm
1/2 Cycle
1/2 Cycle
90-140 Vrms
90.0 Vrms
10.0 Vrms
10 mArms
14.1K Ohm
10
40
18-36 Vrms
18.0 Vrms
2.0 Vrms
10 mArms
2.1k Ohm
10
40
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
Parameters
4000 VRMS
109 Ohms
8 pF
-30 to 80°C
-30 to 125 °C
0.32 lb (145.5g)
Themally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) See derating chart on page 3.
3) Steady state load current exceeding 10 amps will damage socket.
4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
5) Turn-on time for DC control random turn-on versions is 0.1 msec
**NOTE: Voltages in excess of 380V will damage output terminals.
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
E116950 (relay only)
Rev. 110811
ANNEX - ENVIROMENTAL INFORMATION