PCV Series • Proportional controller • Ratings from 15A to 90A @ 240 VAC • 2-7 V DC or 2-10 V DC analog input range • For use with resistive loads only PRODUCT SELECTION Description 2-7 VDC Control 2-10 VDC Control 15 A 25 A 50 A 75 A 90 A 7PCV2415 10PCV2415 7PCV2425 10PCV2425 10PCV2450 10PCV2475 10PCV2490 OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) Maximum Load Current (3) [Arms] Minimum Load Current [Arms] Maximum Surge Current (16.6ms) [Apk] Maximum On-State Voltage Drop @ Rated Current [Vpk] Maximum I² t for Fusing (8.3 msec) [A² sec] Minimum Power Factor (with Maximum Load) 15 A 25 A 50 A 75 A 90 A 100-240 600 10 200 15 0.15 150 1.6 94 0.5 100-240 600 10 200 25 0.15 250 1.6 260 0.5 100-240 600 10 200 50 0.15 625 1.6 1620 0.5 100-240 600 10 200 75 0.15 1000 1.6 4150 0.5 100-240 600 10 200 90 0.15 1200 1.6 6000 0.5 INPUT SPECIFICATIONS (1) Description Control Voltage Range Typical Input Current @ 5 VDC 7PCV24xx 10PCV24xx 2-7 VDC 4 mA 2-10 VDC 4 mA GENERAL SPECIFICATIONS Description Dielectric Strength, Signal to Load (50/60Hz) Dielectric Strength, Signal to Base Ambient Operating Temperature Range Ambient Storage Temperature Range Weight (typical) Encapsulation Terminals GENERAL NOTES 1) All parameters at 25°C unless otherwise specified. Parameters 2500 Vrms 2500 Vrms -30 to 80 °C -40 to 125 °C 3.5 oz. (100g) Themaly Conductive Epoxy Screws and Saddle clamps Furnished, Unmounted MECHANICAL SPECIFICATIONS WIRING DIAGRAM THERMAL DERATE INFORMATION TYPICAL APPLICATIONS • Industrial temperature controllers • Light dimming • Vibratory feeders • Resistive heating elements • Rectified DC motors • Conveyor speed control UNSUITABLE APPLICATIONS The PCV is not suitable for some load applications Including, but not limited to the following: • AC motor control • Three Phase motors • Transformers requiring pure sine wave input • Zero crossing applications Please contact Crydom’s application Engineering department for additional Information and specific application questions. AGENCY APPROVALS E116950 LR81689-73 Rev. 042012 ANNEX - ENVIROMENTAL INFORMATION