UT700 LEON 3FT Datasheet 9-14.fm

Standard Products
UT700 32-bit Fault-Tolerant
SPARCTM V8/LEON 3FT Processor
Datasheet
March 2015
www.aeroflex.com/LEON
INTRODUCTION
The UT700 features a seven stage pipelined monolithic, highperformance, fault-tolerant SPARCTM V8/LEON 3FT
Processor. L1 cache consists of 16kB for both instruction and
data caches. A Reed Solomon EDAC provides fault-tolerant
protection for SDRAM. Integer performance is 1.2 DMIPS /
MHz. RMAP protocol is supported for all four SpaceWire ports.
The UT700 provides a 32-bit master/target PCI interface,
including a 16 bit user I/O interface for off-chip peripherals. A
compliant 2.0 AMBA bus interface integrates the on-chip LEON
3FT, SpaceWire, Ethernet, memory controller, cPCI, CAN bus,
MIL-STD-1553, SPI and programmable interrupt peripherals.
FEATURES
 Supports up to 166 MHz clock rate
 Separate instruction and data cache architecture
 High-performance fully pipelined IEEE-754 FPU
 Enhanced pipeline with 1.2 DMIPS / MHz performance
 Implemented on 130nm CMOS technology
 Internally configured clock network
 Power saving 1.2V core power supply
 3.3V I/O compatibility
 Hardened-by-design flip-flops and memory cells
 Reed Solomon EDAC
 Multifunctional memory controller
 10/100 Base-T Ethernet port for VxWorks development
 Integrated PCI 2.2 compatible core
 Four integrated multi-protocol SpaceWire nodes that
support the RMAP protocol
 SPI interface
 Two CAN 2.0 compliant bus interfaces
 MIL-STD-1553 BC/RT/MT
The UT700 is SPARC V8 compliant; therefore, developers may
use industry standard compilers, kernels, and development
tools. A full software development suite is available including
a C/C++ cross-compiler system based on GCC and the Newlib
embedded C-library.
BCC includes a small run-time kernel with interrupt support and
Pthreads library. For multi-threaded applications, a SPARCTM
compliant port of the eCos real-time kernel, RTEMS 4.10, and
VxWorks 6.x is supported.
 -55oC to +105oC temperature range
 Operational environment:
- Intrinsic total-dose: 100 krad(Si)
- SEL Immune <110 MeV-cm2/mg
 Packaging options:
- 484-pin Ceramic Land Grid, Column Grid and Ball
Grid Array packages
 Standard Microcircuit Drawing 5962-13238
- QML Q, Q+, and V
 Applications
- Nuclear power plant controls
- Critical transportation systems
- High-altitude avionics
- Medical electronics
- X-Ray cargo scanning
- Spaceborne computer
- System controller boards
- Avionics processing boards
36-00-00-000
Ver. 1.3.1
1
Aeroflex Microelectronics Solutions - HiRel
1.0 Introduction
The UT700 LEON 3FT processor is based upon the industry-standard SPARC V8 architecture. The system-on-chip incorporates the
SPARC V8 core and the peripheral blocks indicated below. The core and peripherals communicate internally via the AMBA
(Advanced Microcontroller Bus Architecture) interconnect. This bus is comprised of the AHB (Advanced High-speed Bus) which is
used for high-speed data transfer, and the APB (Advanced Peripheral Bus) which is used for low-speed data transfer.
IEEE-754
FPU
LEON 3FT
MUL/DIV
4x4kB
Data Cache
4x4kB
Instr Cache
Debug
Support
Unit
JTAG
Debug
Link
SpW w/
RMAP
(4)
PCI
Bridge
Ethernet
MAC
CAN
(2)
SPI
MMU
AHB Interface
AMBA AHB
AHB
Controller
AMBA APB
AHB/APB
Bridge
FT Memory
Controller
512MB
PROM
256MB
I/O
Up to
1GB
SRAM
APB
UART
Timers
(4)
INT
Ctrl
GPIO
Clock
Gating
MILSTD1553
Up to
1GB
SDRAM
Figure 1. UT700 Functional Block Diagram
The LEON 3FT architecture includes the following peripheral blocks:
• LEON3 SPARC V8 integer unit with 16kB instruction cache and 16kB of data cache
• IEEE-754 floating point unit
• Debug support unit
• UART, JTAG, SpaceWire, PCI, and Ethernet debug links
• 8/16/32-bit memory controller with BCH EDAC for external PROM and SRAM
• 32-bit SDRAM controller with Reed Solomon EDAC for external SDRAM
• Timer unit with three 32-bit timers and watchdog
• Interrupt controller for 15 interrupts in two priority levels
• 16-bit general purpose I/O port (GPIO) which can be used as external interrupt sources
• Up to four SpaceWire links with RMAP on all channels
• MIL-STD-1553 interface supports BC/RT/MT
• Up to two CAN controllers
• Ethernet with support for MII
• cPCI interface with 8-channel arbiter
36-00-00-000
Ver. 1.3.1
2
Aeroflex Microelectronics Solutions - HiRel
2.0 Pin Identification and Description
Pin Function
I
IS
O
I/O
OD
PCI-I
PCI-O
PCI-I/O
PCI-3
Description
CMOS input
CMOS input Schmitt
CMOS output
CMOS bi-direct
CMOS open drain
PCI input
PCI output
PCI bi-direct
PCI three-state
2.1. System Signals
Pin Name
Function
Pin
Number
Reset
Value
Description
484 CLGA
SYSCLK
I
Y20
--
Main system clock
NODIV
I
E19
--
Clock divider input. Set to ‘1’ for 1x memory clock,
‘0’ for 1/2x memory clock, relative to SYSCLK.
RESET
IS
L19
--
System reset
ERROR1
OD
K19
--
Processor error mode indicator. This is an active low
output.
WDOG1
OD
J19
--
Watchdog indicator. This is an active low output.
Notes:
1. This pin is actively driven low and must be tied to VDD through a pull-up resistor.
2.2 Address Bus
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
ADDR[0]
O
W5
low
Bit 0 of the address bus
ADDR[1]
O
Y5
low
Bit 1 of the address bus
ADDR[2]
O
W6
low
Bit 2 of the address bus
ADDR[3]
O
AA5
low
Bit 3 of the address bus
ADDR[4]
O
Y6
low
Bit 4 of the address bus
ADDR[5]
O
AB5
low
Bit 5 of the address bus
ADDR[6]
O
W7
low
Bit 6 of the address bus
36-00-00-000
Ver. 1.3.1
3
Aeroflex Microelectronics Solutions - HiRel
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
ADDR[7]
O
AA6
low
Bit 7 of the address bus
ADDR[8]
O
Y7
low
Bit 8 of the address bus
ADDR[9]
O
AA7
low
Bit 9 of the address bus
ADDR[10]
O
AB6
low
Bit 10 of the address bus
ADDR[11]
O
W8
low
Bit 11 of the address bus
ADDR[12]
O
AB7
low
Bit 12 of the address bus
ADDR[13]
O
Y8
low
Bit 13 of the address bus
ADDR[14]
O
AA8
low
Bit 14 of the address bus
ADDR[15]
O
W9
low
Bit 15 of the address bus
ADDR[16]
O
AB8
low
Bit 16 of the address bus
ADDR[17]
O
Y9
low
Bit 17 of the address bus
ADDR[18]
O
W10
low
Bit 18 of the address bus
ADDR[19]
O
AB9
low
Bit 19 of the address bus
ADDR[20]
O
Y10
low
Bit 20 of the address bus
ADDR[21]
O
AA9
low
Bit 21 of the address bus
ADDR[22]
O
W11
low
Bit 22 of the address bus
ADDR[23]
O
AA10
low
Bit 23 of the address bus
ADDR[24]
O
Y11
low
Bit 24 of the address bus
ADDR[25]
O
AB10
low
Bit 25 of the address bus
ADDR[26]
O
AB11
low
Bit 26 of the address bus
ADDR[27]
O
AA11
low
Bit 27 of the address bus
2.3 Data Bus
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
DATA[0]
I/O
W12
high-z
Bit 0 of the data bus
DATA[1]
I/O
W13
high-z
Bit 1 of the data bus
DATA[2]
I/O
Y12
high-z
Bit 2 of the data bus
36-00-00-000
Ver. 1.3.1
4
Aeroflex Microelectronics Solutions - HiRel
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
DATA[3]
I/O
AA13
high-z
Bit 3 of the data bus
DATA[4]
I/O
AA12
high-z
Bit 4 of the data bus
DATA[5]
I/O
AB13
high-z
Bit 5 of the data bus
DATA[6]
I/O
W14
high-z
Bit 6 of the data bus
DATA[7]
I/O
AA14
high-z
Bit 7 of the data bus
DATA[8]
I/O
Y13
high-z
Bit 8 of the data bus
DATA[9]
I/O
W15
high-z
Bit 9 of the data bus
DATA[10]
I/O
AB15
high-z
Bit 10 of the data bus
DATA[11]
I/O
Y14
high-z
Bit 11 of the data bus
DATA[12]
I/O
AB14
high-z
Bit 12 of the data bus
DATA[13]
I/O
W16
high-z
Bit 13 of the data bus
DATA[14]
I/O
AA18
high-z
Bit 14 of the data bus
DATA[15]
I/O
Y15
high-z
Bit 15 of the data bus
DATA[16]
I/O
AB16
high-z
Bit 16 of the data bus
DATA[17]
I/O
AA15
high-z
Bit 17 of the data bus
DATA[18]
I/O
AB17
high-z
Bit 18 of the data bus
DATA[19]
I/O
AA16
high-z
Bit 19 of the data bus
DATA[20]
I/O
AA19
high-z
Bit 20 of the data bus
DATA[21]
I/O
W17
high-z
Bit 21 of the data bus
DATA[22]
I/O
AB18
high-z
Bit 22 of the data bus
DATA[23]
I/O
Y16
high-z
Bit 23 of the data bus
DATA[24]
I/O
Y17
high-z
Bit 24 of the data bus
DATA[25]
I/O
AA17
high-z
Bit 25 of the data bus
DATA[26]
I/O
W18
high-z
Bit 26 of the data bus
DATA[27]
I/O
AB19
high-z
Bit 27 of the data bus
DATA[28]
I/O
Y19
high-z
Bit 28 of the data bus
DATA[29]
I/O
AB20
high-z
Bit 29 of the data bus
DATA[30]
I/O
Y18
high-z
Bit 30 of the data bus
DATA[31]
I/O
AA20
high-z
Bit 31 of the data bus
36-00-00-000
Ver. 1.3.1
5
Aeroflex Microelectronics Solutions - HiRel
2.4 Check Bits
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
CB[0]
I/O
V19
high-z
Bit 0 of EDAC BCH/RS checkbits
CB[1]
I/O
AA21
high-z
Bit 1 of EDAC BCH/RS checkbits
CB[2]
I/O
Y21
high-z
Bit 2 of EDAC BCH/RS checkbits
CB[3]
I/O
W19
high-z
Bit 3 of EDAC BCH/RS checkbits
CB[4]
I/O
Y22
high-z
Bit 4 of EDAC BCH/RS checkbits
CB[5]
I/O
W20
high-z
Bit 5 of EDAC BCH/RS checkbits
CB[6]
I/O
W22
high-z
Bit 6 of EDAC BCH/RS checkbits
CB[7]
I/O
W21
high-z
Bit 7 of EDAC BCH/RS checkbits
CB[8]
I/O
V18
high
Bit 8 of EDAC RS checkbits
CB[9]
I/O
U18
high
Bit 9 of EDAC RS checkbits
CB[10]
I/O
T18
high
Bit 10 of EDAC RS checkbits
CB[11]
I/O
R18
high
Bit 11 of EDAC RS checkbits
CB[12]
I/O
P18
high
Bit 12 of EDAC RS checkbits
CB[13]
I/O
N18
high
Bit 13 of EDAC RS checkbits
CB[14]
I/O
M18
high
Bit 14 of EDAC RS checkbits
CB[15]
I/O
M19
high
Bit 15 of EDAC RS checkbits
2.5 Memory Control Signals
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
WRITE
O
V21
high
PROM and I/O write enable strobe
OE
O
U19
high
PROM and I/O output enable
IOS
O
T20
high
I/O area chip select
ROMS[0]
O
V22
high
PROM chip select
ROMS[1]
O
U20
high
PROM chip select
RWE[0]
O
U22
high
SRAM write enable strobe
RWE[1]
O
T19
high
SRAM write enable strobe
36-00-00-000
Ver. 1.3.1
6
Aeroflex Microelectronics Solutions - HiRel
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
RWE[2]
O
T22
high
SRAM write enable strobe
RWE[3]
O
T21
high
SRAM write enable strobe
RAMOE[0]
O
V20
high
SRAM output enable
RAMOE[1]
O
R21
high
SRAM output enable
RAMOE[2]
O
R20
high
SRAM output enable
RAMOE[3]
O
R22
high
SRAM output enable
RAMOE[4]
O
R19
high
SRAM output enable
RAMS[0]
O
P22
high
SRAM chip select
RAMS[1]
O
P20
high
SRAM chip select
RAMS[2]
O
P21
high
SRAM chip select
RAMS[3]
O
P19
high
SRAM chip select
RAMS[4]
O
N19
high
SRAM chip select
READ
O
K20
high
SRAM, PROM, and I/O read indicator
BEXC
I
K22
--
Bus exception
BRDY
I
K21
--
Bus ready
2.6 SDRAM
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
SDCLK
O
AB12
high
SDRAM clock
SDRAS
O
N22
high
SDRAM row address strobe
SDCAS
O
N20
high
SDRAM column address strobe
SDWE
O
N21
high
SDRAM write enable
SDCS[0]
O
M21
high
SDRAM chip select
SDCS[1]
O
M22
high
SDRAM chip select
SDDQM[0]
O
L21
high
SDRAM data mask
SDDQM[1]
O
M20
high
SDRAM data mask
SDDQM[2]
O
L20
high
SDRAM data mask
36-00-00-000
Ver. 1.3.1
7
Aeroflex Microelectronics Solutions - HiRel
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
SDDQM[3]
O
L22
high
SDRAM data mask
2.7 CAN 2.0 Interface
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
CAN_RXD[0]
I
J20
--
CAN receive data
CAN_TXD[0]
O
J22
high
CAN transmit data
CAN_RXD[1]
I
J21
--
CAN receive data
CAN_TXD[1]
O
H22
high
CAN transmit data
2.8 Debug Support Unit (DSU)
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
DSUACT
O
H19
low
DSUmode indicator
DSUBRE
I
H20
--
DSU break
DSUEN
I
G19
--
DSU enable
DSURX
I
G20
--
DSU UART receive data
DSUTX
O
G21
high
DSU UART transmit data
2.9 JTAG Interface
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
TRST
I
F20
--
JTAG reset
TMS
I
F21
--
JTAG test mode select
TCK
I
G22
--
JTAG clock
TDI
I
F22
--
JTAG test data input
36-00-00-000
Ver. 1.3.1
8
Aeroflex Microelectronics Solutions - HiRel
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
TDO
O
F19
undef
JTAG test data output
2.10 Ethernet Interface
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
EMDC
O
E22
low
ERX_CLK
I
D22
--
EMDIO
I/O
D20
high-z
ERX_COL
I
E21
--
Ethernet collision error
ERX_CRS
I
E20
--
Ethernet carrier sense detect
ERX_DV
I
D21
--
Ethernet receiver data valid
ERX_ER
I
C21
--
Ethernet reception error
ERXD[0]
I
C22
--
Ethernet receive data
ERXD[1]
I
B21
--
Ethernet receive data
ERXD[2]
I
C20
--
Ethernet receive data
ERXD[3]
I
B20
--
Ethernet receive data
ETXD[0]
O
C19
low
Ethernet transmit data
ETXD[1]
O
C18
high
Ethernet transmit data
ETXD[2]
O
B18
low
Ethernet transmit data
ETXD[3]
O
B19
high
Ethernet transmit data
ETX_CLK
I
A19
--
ETX_EN
O
A18
low
Ethernet transmit enable
ETX_ER
O
A20
low
Ethernet transmit error. Always driven low.
EDCLDIS
I
E17
--
Ethernet EDCL disable
EMDINT
I
E18
--
Ethernet management interface data interrupt
36-00-00-000
Ver. 1.3.1
9
Ethernet media interface clock
Ethernet RX clock
Ethernet media interface data
Ethernet TX clock
Aeroflex Microelectronics Solutions - HiRel
2.11 General Purpose I/O
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
GPIO[0]
I/O
B17
high-z
Bit 0 of general purpose I/O
GPIO[1]
I/O
C17
high-z
Bit 1 of general purpose I/O
GPIO[2]
I/O
A17
high-z
Bit 2 of general purpose I/O
GPIO[3]
I/O
D17
high-z
Bit 3 of general purpose I/O
GPIO[4]
I/O
C16
high-z
Bit 4 of general purpose I/O
GPIO[5]
I/O
D16
high-z
Bit 5 of general purpose I/O
GPIO[6]
I/O
C15
high-z
Bit 6 of general purpose I/O
GPIO[7]
I/O
D15
high-z
Bit 7 of general purpose I/O
GPIO[8]
I/O
C7
high-z
Bit 8 of general purpose I/O
GPIO[9]
I/O
B5
high-z
Bit 9 of general purpose I/O
GPIO[10]
I/O
D7
high-z
Bit 10 of general purpose I/O
GPIO[11]
I/O
A5
high-z
Bit 11 of general purpose I/O
GPIO[12]
I/O
D6
high-z
Bit 12 of general purpose I/O
GPIO[13]
I/O
C5
high-z
Bit 13 of general purpose I/O
GPIO[14]
I/O
C6
high-z
Bit 14 of general purpose I/O
GPIO[15]
I/O
D5
high-z
Bit 15 of general purpose I/O
2.12 SpaceWire Interface
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
SPW_CLK
I
A11
--
SpaceWire clock
SPW_RXS[0]
I
A16
--
SpaceWire receive strobe
SPW_RXD[0]
I
A15
--
SpaceWire receive data
SPW_TXS[0]
O
B16
low
SpaceWire transmit strobe
SPW_TXD[0]
O
B15
low
SpaceWire transmit data
SPW_RXS[1]
I
A14
--
SpaceWire receive strobe
SPW_RXD[1]
I
A13
--
SpaceWire receive data
36-00-00-000
Ver. 1.3.1
10
Aeroflex Microelectronics Solutions - HiRel
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
SPW_TXS[1]
O
B14
low
SpaceWire transmit strobe
SPW_TXD[1]
O
B13
low
SpaceWire transmit data
SPW_RXS[2]
I
A9
--
SpaceWire receive strobe
SPW_RXD[2]
I
A8
--
SpaceWire receive data
SPW_TXS[2]
O
B9
low
SpaceWire transmit strobe
SPW_TXD[2]
O
B8
low
SpaceWire transmit data
SPW_RXS[3]
I
A7
--
SpaceWire receive strobe
SPW_RXD[3]
I
A6
--
SpaceWire receive data
SPW_TXS[3]
O
B7
low
SpaceWire transmit strobe
SPW_TXD[3]
O
B6
low
SpaceWire transmit data
2.13 UART Interface
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
RXD
I
C12
--
UART receive data
TXD
O
C11
high
UART transmit data
2.14 PCI Address and Data Bus
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
PCI_AD[0]
PCI-I/O
AA2
high-z
Bit 0 of PCI address and data bus
PCI_AD[1]
PCI-I/O
AA3
high-z
Bit 1 of PCI address and data bus
PCI_AD[2]
PCI-I/O
Y1
high-z
Bit 2 of PCI address and data bus
PCI_AD[3]
PCI-I/O
Y2
high-z
Bit 3 of PCI address and data bus
PCI_AD[4]
PCI-I/O
Y3
high-z
Bit 4 of PCI address and data bus
PCI_AD[5]
PCI-I/O
W1
high-z
Bit 5 of PCI address and data bus
PCI_AD[6]
PCI-I/O
W2
high-z
Bit 6 of PCI address and data bus
36-00-00-000
Ver. 1.3.1
11
Aeroflex Microelectronics Solutions - HiRel
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
PCI_AD[7]
PCI-I/O
W3
high-z
Bit 7 of PCI address and data bus
PCI_AD[8]
PCI-I/O
V2
high-z
Bit 8 of PCI address and data bus
PCI_AD[9]
PCI-I/O
V3
high-z
Bit 9 of PCI address and data bus
PCI_AD[10]
PCI-I/O
U1
high-z
Bit 10 of PCI address and data bus
PCI_AD[11]
PCI-I/O
U2
high-z
Bit 11 of PCI address and data bus
PCI_AD[12]
PCI-I/O
U3
high-z
Bit 12 of PCI address and data bus
PCI_AD[13]
PCI-I/O
T1
high-z
Bit 13 of PCI address and data bus
PCI_AD[14]
PCI-I/O
R2
high-z
Bit 14 of PCI address and data bus
PCI_AD[15]
PCI-I/O
R1
high-z
Bit 15 of PCI address and data bus
PCI_AD[16]
PCI-I/O
J1
high-z
Bit 16 of PCI address and data bus
PCI_AD[17]
PCI-I/O
K2
high-z
Bit 17 of PCI address and data bus
PCI_AD[18]
PCI-I/O
K1
high-z
Bit 18 of PCI address and data bus
PCI_AD[19]
PCI-I/O
G1
high-z
Bit 19 of PCI address and data bus
PCI_AD[20]
PCI-I/O
H3
high-z
Bit 20 of PCI address and data bus
PCI_AD[21]
PCI-I/O
H2
high-z
Bit 21 of PCI address and data bus
PCI_AD[22]
PCI-I/O
F1
high-z
Bit 22 of PCI address and data bus
PCI_AD[23]
PCI-I/O
F2
high-z
Bit 23 of PCI address and data bus
PCI_AD[24]
PCI-I/O
E1
high-z
Bit 24 of PCI address and data bus
PCI_AD[25]
PCI-I/O
E2
high-z
Bit 25 of PCI address and data bus
PCI_AD[26]
PCI-I/O
F3
high-z
Bit 26 of PCI address and data bus
PCI_AD[27]
PCI-I/O
D1
high-z
Bit 27 of PCI address and data bus
PCI_AD[28]
PCI-I/O
D2
high-z
Bit 28 of PCI address and data bus
PCI_AD[29]
PCI-I/O
E3
high-z
Bit 29 of PCI address and data bus
PCI_AD[30]
PCI-I/O
D3
high-z
Bit 30 of PCI address and data bus
PCI_AD[31]
PCI-I/O
C1
high-z
Bit 31 of PCI address and data bus
36-00-00-000
Ver. 1.3.1
12
Aeroflex Microelectronics Solutions - HiRel
2.15 PCI Control Signals
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
PCI_RST
PCI-I
C3
--
PCI reset input
PCI_CLK
PCI-I
C2
--
PCI clock input
PCI_C/BE[0]
PCI-I/O
V1
high-z
PCI bus command and byte enable
PCI_C/BE[1]
PCI-I/O
P2
high-z
PCI bus command and byte enable
PCI_C/BE[2]
PCI-I/O
H1
high-z
PCI bus command and byte enable
PCI_C/BE[3]
PCI-I/O
G2
high-z
PCI bus command and byte enable
PCI_PAR
PCI-I/O
P1
high-z
PCI parity checkbit
PCI_FRAME1
PCI-3
L1
high-z
PCI cycle frame indicator
PCI_IRDY1
PCI-3
L2
high-z
PCI initiator ready indicator
PCI_TRDY1
PCI-3
M1
high-z
PCI target ready indicator
PCI_STOP1
PCI-3
N1
high-z
PCI target stop request
PCI_DEVSEL1
PCI-3
M2
high-z
PCI device select
PCI_PERR1
PCI-3
N2
high-z
PCI parity error indicator
PCI_IDSEL
PCI-I
G3
--
PCI_REQ
PCI-O
A4
high-z
PCI request to arbiter in point to point configuration
PCI_GNT
PCI-I
B2
--
PCI bus access indicator in point to point configuration
PCI_HOST
PCI-I
AB3
--
PCI host enable input (Connect to SYSEN in PCI bus)
PCI initialization device select
Notes:
1. This pin must be tied to VDD through a pull-up resistor as specified in the PCI Local Bus Specification Revision 2.1 Section 4.3.3.
2.16 PCI Arbiter
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
PCI_ARB_REQ[0]
PCI-I
B4
--
PCI arbiter bus request
PCI_ARB_REQ[1]
PCI-I
AB4
--
PCI arbiter bus request
36-00-00-000
Ver. 1.3.1
13
Aeroflex Microelectronics Solutions - HiRel
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
PCI_ARB_REQ[2]
PCI-I
Y4
--
PCI arbiter bus request
PCI_ARB_REQ[3]
PCI-I
T3
--
PCI arbiter bus request
PCI_ARB_REQ[4]
PCI-I
P3
--
PCI arbiter bus request
PCI_ARB_REQ[5]
PCI-I
M3
--
PCI arbiter bus request
PCI_ARB_REQ[6]
PCI-I
K3
--
PCI arbiter bus request
PCI_ARB_REQ[7]
PCI-I
C4
--
PCI arbiter bus request
PCI_ARB_GNT[0]
PCI-O
B3
high-z
PCI arbiter bus grant
PCI_ARB_GNT[1]
PCI-O
AA4
high-z
PCI arbiter bus grant
PCI_ARB_GNT[2]
PCI-O
W4
high-z
PCI arbiter bus grant
PCI_ARB_GNT[3]
PCI-O
R3
high-z
PCI arbiter bus grant
PCI_ARB_GNT[4]
PCI-O
N3
high-z
PCI arbiter bus grant
PCI_ARB_GNT[5]
PCI-O
L3
high-z
PCI arbiter bus grant
PCI_ARB_GNT[6]
PCI-O
J3
high-z
PCI arbiter bus grant
PCI_ARB_GNT[7]
PCI-O
A3
high-z
PCI arbiter bus grant
2.17 Serial Peripheral Interface (SPI)
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
SPICLK
O
E12
SPI Clock
SPIMOSI
O
E13
SPI Master Out Slave In
SPIMISO
I
E11
SPISLVSEL
O
E10
--
SPI Master In Slave Out
SPI Select
2.18 MIL-STD-1553 Signals
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
1553CLK
36-00-00-000
Ver. 1.3.1
I
B11
--
14
MIL-STD-1553B Clock
Aeroflex Microelectronics Solutions - HiRel
Pin Name
Direction
Pin
Number
Reset
Value
Description
484 CLGA
1553RXA
I
C13
--
MIL-STD-1553B Receive Positive A
1553RXA
I
D12
--
MIL-STD-1553B Receive Negative A
1553RXB
I
C8
--
MIL-STD-1553B Receive Positive B
1553RXB
I
C9
--
MIL-STD-1553B Receive Negative B
1553RXENA
O
D11
high-z
MIL-STD-1553B Receive Enable A
1553RXENB
O
D9
high-z
MIL-STD-1553B Receive Enable B
1553TXINHA
O
D13
high-z
MIL-STD-1553B Transmit Inhibit A
1553TXINHB
O
D10
high-z
MIL-STD-1553B Transmit Inhibit B
1553TXA
O
D14
high-z
MIL-STD-1553B Transmit Positive A
1553TXA
O
C14
high-z
MIL-STD-1553B Transmit Negative A
1553TXB
O
B10
high-z
MIL-STD-1553B Transmit Positive B
1553TXB
O
C10
high-z
MIL-STD-1553B Transmit Negative B
2.19 Power and Ground Pins
Pin Number
Pin Name
Description
484 CLGA
VDD
B1, B12, B22, E7, E9, E14, E16, F6, F10, F13, F17, G5, G9, G14,
H6, H8, H10, H13, H15, J7, J16, K5, K8, K15, K17, L6, M6, N5, N8,
N15, N17, P7, P16, R6, R8, R10, R13, R15, T5, T9, T14, U6, U9,
U11, U12, U14, U17, V10, V13, AA1, AA22
I/O supply voltage
VSS
A1, A12, A22, E6, F4, G4, G8, G11, G12, G15, G17, H4, H7, H16,
H18, J2, J4, J9, J14, K4, K10, K13, L7, L11, L12, L17, M7, M11,
M12, M17, N4, N10, N13, P4, P9, P14, R4, R7, R16, T2, T4, T8,
T15, T17, U4, U10, U13, V4, V5, V8, V11, V12, V15, AB1, AB22
I/O supply ground
VDDC
A2, A21, E5, F8, F15, G7, G10, G13, G16, G18, H5, H9, H11, H12,
H14, H17, J6, J8, J15, K7, K16, L8, L15, L18, M4, M8, M15, N7,
N16, P6, P8, P15, R5, R9, R11, R12, R14, R17, T7, T10, T13, T16,
U8, U15, V6, V17, AB2, AB21
Core supply voltage
VSSC
A10, E8, E15, F5, F7, F9, F11, F12, F14, F16, F18, G6, H21, J5, J10,
J11, J12, J13, J17, K6, K9, K11, K12, K14, K18, L5, L9, L10, L13,
L14, L16, M5, M9, M10, M13, M14, M16, N6, N9, N11, N12, N14,
P5, P10, P11, P12, P13, P17, T6, T11, T12, U5, U7, U16, U21, V7,
V14, V16
Core supply ground
36-00-00-000
Ver. 1.3.1
15
Aeroflex Microelectronics Solutions - HiRel
Pin Number
Pin Name
Description
484 CLGA
N/C
D4, D18, E4, J18, L4, V9
No connect. These pins may be left
floating, or tied to VDD or VSS
Unused
D8
This pin may be left floating or tied to
VSS
Unused
D19
This pin must be tied to VSS
2.20 Bootstrap Signals
The states of the following signals are latched in upon the rising edge of reset in order to configure the UT700 for the indicated
operation.
Pin Name
GPIO[1:0]
GPIO[2]
GPIO[7:4]
GPIO[15:12]
36-00-00-000
Ver. 1.3.1
Function
Sets the data width of the PROM area
00: 8 bits
01: 16 bits
10: 32 bits
11: Not used
Enable EDAC checking of the PROM area
0: EDAC disabled
1: EDAC enabled
Set the SpW clock divisor link bits in the SpW Clock Divisor Register
Sets the least significant address nibble of the IP and MAC address for the Ethernet Debug Communication Link (EDCL)
16
Aeroflex Microelectronics Solutions - HiRel
3.0 AC and DC Electrical Specifications
3.1 Absolute Maximum Ratings1
Symbol
Description
Min
Max
Units
VDDC
Core supply voltage
-0.3
1.85
V
VDD
I/O supply voltage
-0.3
5.2
V
VIN
Input voltage any pin
VSS - 0.3
VDD + 0.3
V
PD2
Maximum power dissipation permitted @
TC = 105oC
--
4
W
Junction temperature
--
150
--
5
oC/W
-65
150
oC
2000
--
V
TJ
ΘJC
Thermal resistance, junction to case
TSTG
Storage temperature
ESDHBM
484 CLGA/CCGA/CBGA
ESD protection (human body model) Class 2
o
C
Notes:
1. Stresses greater than those listed in the following table can result in permanent damage to the device. These parameters cannot be violated.
2. Per MIL-STD-883, Method 1012, Section 3.4.1, PD = (TJ(max)-Tc(max))/ΘJC
36-00-00-000
Ver. 1.3.1
17
Aeroflex Microelectronics Solutions - HiRel
3.2 Recommended Operating Conditions
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55°C to 105°C)
Symbol
Description
Min
Max
Units
VDDC
Core supply voltage
1.1
1.3
V
VDD
I/O supply voltage
3.0
3.6
V
VIN
Input voltage any pin
0
VDD
V
TC
Case operating temperature
-55
105
o
tR
Rise time, all CMOS and PCI inputs
(0.1VDD to 0.9VDD)
--
20
ns
tF
Fall time, all CMOS and PCI inputs
(0.9VDD to 0.1VDD)
--
20
ns
C
3.3 Operational Environment
The UT700 processor includes the following SEU mitigation features:
* Cache memory error-detecting of up to 4 errors per tag or 32-bit word
* Autonomous and software transparent error handling
* No timing impact due to error detection or correction
PARAMETER
LIMIT
UNITS
Total Ionizing Dose (TID) 1
1E5
rad (Si)
Single Event Latchup Immune (SEL) 2
<110
MeV-cm2/mg
Single Event Upset (SEU) 3, 4
Inherent register upset rate
5.2E-7
errors/device-day
Single Event Upset (SEU) 3, 4
Multiple-bit error (MBE) rate which overcomes internal error detection & correction
architecture
2.8E-11
MBE/device-day
Notes:
1. TID irradation per MIL-STD-883, Test Method 1019, condition A. Post irradiation electrical testing performed at room temperature.
2. Worst case temperature of TC = +105oC, VDD = 3.6V, VDD = 1.3V.
3. Contact factory for additional information regarding the determination of the inherent and multiple-bit upset rates.
4. The error rate calculation was performed using SpaceRad 6.0 for a Geosynchronous orbit in the Adams 90% worst-case environment with 100mil Al shielding.
36-00-00-000
Ver. 1.3.1
18
Aeroflex Microelectronics Solutions - HiRel
3.4 Power Supply Operating Characteristics (pre- and post-radiation)
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
IDDCS
Standby core power supply quiescent current
Conditions
Standby I/O power supply quiescent current
Max
Units
--
8
mA
TC = 105oC
--
100
TC = 25oC
--
50
TC = -55oC
--
0.7
--
2
TC = -55oC
VDDC = 1.3V, VDD= 3.6V
All clock inputs at 0MHz
and 25oC
RHA: R
IDDS
Min
VDDC = 1.3V, VDD = 3.6V
All clock inputs at 0MHz
and 25oC
TC = 105oC
36-00-00-000
Ver. 1.3.1
mA
19
Aeroflex Microelectronics Solutions - HiRel
3.5 DC Characteristics for LVCMOS3 Inputs (pre- and post-radiation)
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
Conditions
Min
Max
Units
VIH1
High-level input voltage
0.7VDD
--
V
VIL1
Low-level input voltage
--
0.3VDD
V
VT+
Positive going threshold voltage for Schmitt
inputs
--
0.7VDD
V
VT-
Negative going threshold voltage for Schmitt
inputs
0.3VDD
--
V
VH
Hysteresis voltage for Schmitt inputs
0.4
--
V
IIN
Input leakage current
(All inputs except pull-ups and pull-downs)
VIN = VDD
--
1
μA
VIN = VSS
-1
--
VIN = VDD
-10
10
VIN = VSS
-100
-10
Input leakage current for pins with internal
pull-down resistors
(EDCLDIS, SPIMISO, 1553CLK, 1553RXA,
1553RXA, 1553RXB, and 1553RXB)
VIN = VDD
+10
+150
VIN = VSS
-10
10
Input pin capacitance
f = 1MHz; VDD = 0V,
VDDC = 0V
--
16
IIN
IIN
CIN2
Input leakage current for pins with internal
pull-up resistors
(CB[15:8], EMDINT, and NODIV)
μA
μA
pF
Notes:
1. JTAG inputs are not tested.
2. Capacitance is measured for initial qualification and when design changes might affect the input/output capacitance.
36-00-00-000
Ver. 1.3.1
20
Aeroflex Microelectronics Solutions - HiRel
3.6 DC Characteristics for LVCMOS3 Outputs (pre- and post-radiation)
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
VOL11
Low-level output voltage
(All outputs except those listed below and in
Section 3.8)
High-level output voltage
(All outputs except those listed below and in
Section 3.8)
IOH = -100μA
VOH11,2
VOL2
VOH2
VOL3
VOH3
VOL4
VOH4
IOZ
IOS3
COUT4
Min
Max
Units
IOL = 100μA
--
0.25
V
IOL = 4mA
--
0.4
VDD-0.25
--
IOH = -4mA
2.4
--
Low-level output voltage
(GPIO[15:0], SPW_TXD[3:0],
SPW_TXS[3:0], TXD)
IOL = 100μA
--
0.25
IOL = 12mA
--
0.4
High-level output voltage
(GPIO[15:0], SPW_TXD[3:0],
SPW_TXS[3:0], TXD)
IOH = -100μA
VDD-0.25
--
IOH = -12mA
2.4
--
Low-level output voltage
(WRITE, OE, IOS, ROMS[1:0], RWE [3:0],
RAMOE [4:0], RAMS[4:0], SDCS[1:0],
SDRAS, SDCAS, SDWE, SDCLK, READ,
SDDQM[3:0], ADDR[27:0], DATA[31:0]
and CB[15:0])
IOL = 100μA
--
0.25
IOL = 24mA
--
0.4
High-level output voltage
(WRITE, OE, IOS, ROMS[1:0], RWE [3:0],
RAMOE [4:0], RAMS[4:0], SDCS[1:0],
SDRAS, SDCAS, SDWE, SDCLK, READ,
SDDQM[3:0], ADDR[27:0], DATA[31:0]
and CB[15:0])
IOH = -100μA
VDD-0.25
--
IOH = -24mA
2.4
--
Low-level output voltage
(SPICLK, SPIMOSI, SPISLVSEL)
IOL = 100μA
--
0.25
IOL = 8mA
--
0.4
VDD-0.25
--
IOH = -8mA
2.4
--
VO = VDD
-10
10
VO = VSS
-10
10
VO = VDD; VDD = 3.6V
--
130
VO = VSS; VDD = 3.6V
-65
--
--
16
High-level output voltage
(SPICLK, SPIMOSI, SPISLVSEL)
Three-state output current
Short-circuit output current
(All outputs except PCI outputs)
Output pin capacitance
Conditions
IOH = -100μA
f = 1MHz; VDD = 0V,
VDDC = 0V
V
V
V
V
V
V
V
μA
mA
pF
Notes:
1. JTAG outputs are not tested.
2. Except open-drain output.
3. Guaranteed by design.
4. Capacitance is measured for initial qualification and when design changes might affect the input/output capacitance.
36-00-00-000
Ver. 1.3.1
21
Aeroflex Microelectronics Solutions - HiRel
3.7 AC Electrical Characteristics for LVCMOS3 Inputs and Outputs (pre- and post-radiation)
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
Conditions
Min
Max
Units
fCLK
System clock frequency
--
166
MHz
tHIGH
System clock high time
2.4
--
ns
tLOW
System clock low time
2.4
--
ns
tDSD1
System clock to SDRAM clock propagation
delay
2.0
6.0
ns
Notes:
1. Reference Figure 17 for test load.
1/fCLK
tHIGH
tLOW
tDSD
tDSD
SYSCLK
SDCLK
tDSD
tDSD
SDCLK
(SYSCLK / 2)
Figure 2. System Clock and SDCLK Timing Diagram
36-00-00-000
Ver. 1.3.1
22
Aeroflex Microelectronics Solutions - HiRel
3.8 DC Electrical Characteristics for PCI Inputs (pre- and post-radiation)
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
Conditions
Min
Max
Units
VIH
High-level input voltage
0.5VDD
--
V
VIL
Low-level input voltage
--
0.3VDD
V
IIN
Input leakage current
VIN = VDD
--
+10
μA
VIN = VSS
-10
--
--
22
pF
Min
Max
Units
CIN1
Input pin capacitance
f = 1MHz; VDD = 0V,
VDDC = 0V
Notes:
1. Capacitance is measured for initial qualification and when design changes might affect the input/output capacitance.
3.9 DC Electrical Characteristics for PCI Outputs (pre- and post-radiation)
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
Conditions
VOH
High-level output voltage
(PCI_AD[31:0], PCI_C/BE[3:0], PCI_RST,
PCI_IDSEL, PCI_FRAME, PCI_IRDY,
PCI_TRDY, PCI_DEVSEL, PCI_STOP,
PCI_PERR, PCI_PAR)
IOH = -500μA
0.9VDD
--
V
VOL
Low-level output voltage
(PCI_AD[31:0], PCI_C/BE[3:0], PCI_RST,
PCI_IDSEL, PCI_FRAME, PCI_IRDY,
PCI_TRDY, PCI_DEVSEL, PCI_STOP,
PCI_PERR, PCI_PAR)
IOL = 1500μA
--
0.1VDD
V
IOZ
Three-state output current
VO = VDD
-10
+10
μA
VO = VSS
-10
+10
VO = VDD; VDD = 3.6V
--
270
VO = VSS; VDD = 3.6V
-130
--
--
22
IOS1
COUT2
Short-circuit output current
Output pin capacitance
f = 1MHz; VDD = 0V,
VDDC = 0V
mA
pF
Notes:
1. Guaranteed by design.
2. Capacitance is measured for initial qualification and when design changes might affect the input/output capacitance.
36-00-00-000
Ver. 1.3.1
23
Aeroflex Microelectronics Solutions - HiRel
3.10 AC Electrical Characteristics for PCI Inputs (pre- and post-radiation)
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
Conditions
Min
Max
Units
fPCI_CLK
PCI clock frequency
--
33
MHz
tHIGH
PCI clock high time
11
--
ns
tLOW
PCI clock low time
11
--
ns
1/fPCI_CLK
tHIGH
tLOW
PCI_CLK
Figure 3. PCI Clock Timing Diagram
36-00-00-000
Ver. 1.3.1
24
Aeroflex Microelectronics Solutions - HiRel
4.0 Timing Specifications
4.1 Power Sequencing and Reset
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
Conditions
Min
Max
Units
tVCD1
VDD valid to VDDC delay
VDD > 3.0V; VDDC > 1.1V
0
--
ns
tVHBZ1
VDD valid to control signals high-z
(WRITE, OE, IOS, ROMS[1:0], RWE[3:0],
RAMOE [4:0], READ SDWE, and
SDCS[1:0])
VDD > 1.5V; VDDC = 0V
--
4
tCLK
VDD valid to outputs high-z
([DATA[31:0], CB[15:0], and GPIO[15:0])
tCHBV1
VDDC valid to control signals valid-inactive
(WRITE, OE, IOS, ROMS[1:0], RWE[3:0],
RAMOE [4:0], READ SDWE, and
SDCS[1:0])
VDD > 3.0V; VDDC > 1.1V
--
4
tCLK
tRESET11
VDDC valid to RESET deassert
VDDC > 1.1V
4
--
tCLK
tRESET21
RESET deasserted to outputs valid-active
(ROMS[0] and OE)
--
12
tCLK
tRESET31
RESET asserted to control signals validinactive
(WRITE, OE, IOS, ROMS[1:0], RWE[3:0],
RAMOE [4:0], READ SDWE, and
SDCS[1:0])
--
4
tCLK
RESET asserted to outputs high-z
(DATA[31:0], CB[15:0], and GPIO[15:0])
Notes:
1. Guaranteed by design.
36-00-00-000
Ver. 1.3.1
25
Aeroflex Microelectronics Solutions - HiRel
SYSCLK
VDD 3.3V
0V
tVCD
VDDC 1.2V
0V
tRESET1
RESET
tCHBV
tVHBZ
Memory Bus
Control Signals
tRESET2
VALID-INACTIVE
tRESET3
VALID-ACTIVE
tVHBZ
VALID-INACTIVE
tRESET3
Tri-State Outputs
VALID-ACTIVE
Figure 4. Power Sequencing and Reset Timing Diagram
4.1.1. Power Sequencing
For optimal power sequencing, both power-up and power-down, ramp both VDD and VDDC together. During power-up, if VDDC >
VDD + 0.3V, excessive current or damage may occur to the device. During power down, it is acceptable for VDD to be less than
VDDC by more than 0.3V as long as VDDC is not actively driven.
4.1.2 Bus Control and Bi-Direct Fail-Safe Circuitry
In order to prevent bus contention on the external memory interface while VDDC is ramping up, the UT700 has functionality to
ensure that the bi-direct and memory bus control signals described in Section 4.1 will be in a high-z state tVHBZ delay after VDD
reaches 1.5V. The core logic will put these signals into their valid-inactive states tCHBV clock cycles after VDDC reaches 1.1V.
Aeroflex recommends that users place pull-up resistors on the indicated output enable, write enable, and chip select pins, and a pulldown resistor on the READ pin, if tVCD is greater than 100ns. This will prevent bus capacitance or transients from inadvertently
placing these pins in an active state, which could result in external memory devices driving the address and data buses.
4.1.3 Reset Circuitry
The reset circuitry is controlled by the core logic; therefore, the circuitry is functional only after VDDC reaches its minimum operating voltage of 1.1V. After VDDC is stable, the system must continue to assert RESET for a minimum of tRESET1 clock cycles before
it can be de-asserted. Asserting RESET for less time could result in the RESET signal not being recognized.
The UT700 will begin fetching code from external memory no more than tRESET2 clock cycles after RESET is de-asserted. Control
signals ROMS[0] and OE will be driven to their valid-active states in order for the UT700 to begin fetching code from PROM.
During normal operation, the indicated bus control signals will go to a valid-inactive state, and the bi-directs will go to a high-z
state, within tRESET3 clock cycles after the assertion of RESET.
36-00-00-000
Ver. 1.3.1
26
Aeroflex Microelectronics Solutions - HiRel
36-00-00-000
Ver. 1.3.1
27
Aeroflex Microelectronics Solutions - HiRel
Boot Strap Programming on GPIO
Data on pins GPIO[2:0], GAPIO[7:4] and GPIO[15:12] are latched on the rising edge of reset. The states of GPIO[2:0] determine
the data width of the PROM area, and enable EDAC for the PROM area. Chapter 3 of the User’s Manual describes the value of
these inputs to achieve the required operation. The states of GPIO[7:4] provides a means to configure the SpaceWire clock divisor
link bits in the Clock Divisor Register. The states of GPIO[15:12] set the least significant address nibble of the IP and MAC address
for the Ethernet Debug Communication Link (EDCL).
In order for the state of GPIO pins to be properly latched, Aeroflex recommends placing pull-up or pull-down resistors on these pins
to ensure that the setup and hold timing is met. The states of these pins should be statically set prior to the rising edge of RESET.
36-00-00-000
Ver. 1.3.1
28
Aeroflex Microelectronics Solutions - HiRel
4.2 Output Timing Characteristics for Memory Interface, ERROR, and WDOG
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
Min
Max
Units
1.5
8.5
ns
t1a1
SDCLK↑ to ADDR[27:0] valid
t1b1
SDCLK↑ to SDCS[1:0] valid
2
7.5
ns
t1c1
SDCLK↑ to output valid
SDRAS, SDCAS, and SDWE
1.5
8.5
ns
t1d1
SDCLK↑ to SDDQM[3:0] valid
2.5
8.5
ns
t1e1
SDCLK↑ to output valid
(WRITE, OE, IOS, ROMS[1:0], RWE [3:0], RAMOE [4:0],
RAMS[4:0], and READ)
1
8
ns
t21,2
SDCLK↑ to output valid
(DATA[31:0] and CB[15:0])
2.5
8.5
ns
t31,2,3
SDCLK↑ to output high-Z
(DATA[31:0] and CB[15:0])
2.5
8.5
ns
SDCLK↑ to signal low
(ERROR and WDOG4)
--
10
ns
WRITE↑ or RWE[3:0]↑ to output high-z
(DATA [31:0] and CB[15:0])
0.5
--
ns
Skew from first memory output signal transition to last memory output
signal transition
--
2
ns
t41
t81,2,3
t91
Notes:
1. All outputs are measured using the load conditions shown in Figure 17.
2. CB[7] is not tested in the case of BCH EDAC.
3. High-Z defined as +/-300mV change from steady state.
4. Guaranteed by design.
36-00-00-000
Ver. 1.3.1
29
Aeroflex Microelectronics Solutions - HiRel
SDCLK
t1a
t9
ADDR[27:0]
t1b
SDCS
t1c
SDRAS, SDCAS, and SDWE
t1d
SDDQM[3:0]
WRITE and RWE[3:0]
t8
t2
t3
DATA[31:0] and CB[15:0]
t4
ERROR and WDOG
t1e
All Other Outputs
Figure 5. Memory Interface, ERROR, and WDOG Output Timing Diagram
36-00-00-000
Ver. 1.3.1
30
Aeroflex Microelectronics Solutions - HiRel
4.3 Input Timing Characteristics for Memory Interface
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
Min
Max
Units
t5a1
Setup time to SDCLK↑
(DATA[31:0] and CB[15:0])
1
--
ns
t5b
Setup time to SDCLK↑
(BEXC, and synchronous BRDY)
2
--
ns
t6a1
Hold time from SDCLK↑
(DATA[31:0] and CB[15:0])
1.5
--
ns
t6b
Hold time from SDCLK↑
(Synchronous BRDY)
0
--
ns
t72
Asynchronous BRDY pulse width
1.5
--
tCLK
Notes:
1. CB[7] is not tested in the case of BCH EDAC.
2. Supplied as a design limit. Neither guaranteed nor tested.
SDCLK
t6a
t5a
DATA[31:0] and CB[15:0]
t6b
t5b
BEXC and Synchronous BRDY
t7
Asynchronous BRDY
Figure 6. Memory Interface Input Timing Diagram
36-00-00-000
Ver. 1.3.1
31
Aeroflex Microelectronics Solutions - HiRel
4.4 Timing Characteristics for General Purpose Input / Output (GPIO)
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
SDCLK↑ to GPIO output valid
(GPIO[15:0])
t101
Min
Max
Units
--
10
ns
Notes:
1. All outputs are measured using the load conditions shown in Figure 17.
SDCLK
t10
GPIO[15:0]
Figure 7. General Purpose I/O Timing Diagram
36-00-00-000
Ver. 1.3.1
32
Aeroflex Microelectronics Solutions - HiRel
4.5 Timing Characteristics SpaceWire Interface
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
SPW_CLK period
t11 1,2
Transmit data and strobe bit width variation
(SPW_TXD[3:0] and SPW_TXS[3:0])
t14 3,4,5
Min
Max
Units
5
--
ns
UI-600
UI+600
ps
t15 5,6
Receive data and strobe bit width
(SPW_RXD[3:0] and SPW_RXS[3:0])
5
--
ns
t16 5
Receive data and strobe edge separation
(SPW_RXD[3:0] and SPW_RXS[3:0])
1/2*t11 + 0.5
--
ns
Notes:
1. The SPW_CLK frequency must be less than or equal to 10x the SYSCLK frequency. For example, if SPW_CLK is running at 200MHz, the SYSCLK frequency
must be greater than or equal to 20MHz.
2. Functionally tested.
3. Applies to both high pulse and low pulse.
4. A unit interval (UI) is defined as the nominal, or ideal, bit width.
5. Guaranteed by design.
6. The SPW_CLK period must be less than or equal to the minimum receive data/strobe bit width.
t11
SPW_CLK
t14
SPW_TXD
t14
SPW_TXS
Figure 8. SpaceWire Transmit Timing Diagram
t15
SPW_RXD
t16
t16
t15
SPW_RXS
Figure 9. SpaceWire Receive Timing Diagram
36-00-00-000
Ver. 1.3.1
33
Aeroflex Microelectronics Solutions - HiRel
4.6 Timing Characteristics for PCI Interface
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Description
Min
Max
Units
t171
PCI_CLK↑ to output valid
(PCI_AD[31:0], PCI_C/BE[3:0], PCI_PAR, PCI_FRAME,
PCI_IRDY, PCI_TDRY, PCI_STOP, PCI_DEVSEL,
PCI_PERR, PCI_REQ, and PCI_ARB_GNT[7:0])
2
13
ns
t181,2
PCI_CLK↑ to output valid from high-z
(PCI_AD[31:0], PCI_C/BE[3:0], PCI_PAR, PCI_FRAME,
PCI_IRDY, PCI_TDRY, PCI_STOP, PCI_DEVSEL, and
PCI_PERR
2
13
ns
t191,2
PCI_CLK↑ to output high-Z
(PCI_AD[31:0], PCI_C/BE[3:0], PCI_PAR, PCI_FRAME,
PCI_IRDY, PCI_TDRY, PCI_STOP, PCI_DEVSEL, and
PCI_PERR
--
14
ns
t203,4
Setup time to PCI_CLK↑
(PCI_AD[31:0], PCI_C/BE[3:0], PCI_PAR, PCI_FRAME,
PCI_IRDY, PCI_TDRY, PCI_STOP, PCI_DEVSEL,
PCI_PERR, PCI_IDSEL, PCI_GNT, and PCI_ARB_REQ[7:0])
4
--
ns
t213,4
Hold time from PCI_CLK↑
(PCI_AD[31:0], PCI_C/BE[3:0], PCI_PAR, PCI_FRAME,
PCI_IRDY, PCI_TDRY, PCI_STOP, PCI_DEVSEL,
PCI_PERR, PCI_IDSEL, PCI_GNT, and PCI_ARB_REQ[7:0])
1
--
ns
t225
PCI_CLK↑ to RESET deassertion
10
--
PCI Clocks
t23a5
PCI_CLK↑ to PCI_RST deassertion
10
--
PCI Clocks
t23b5
PCI_RST assertion to PCI_CLK idle
10
PCI_RST active to output high-Z
--
t24
PCI Clocks
40
ns
Notes:
1. All outputs are measured using the load conditions shown in Figure 17.
2. High-Z defined as +/-300mV change from steady state.
3. PCI_TRDY, PCI_STOP, and PCI_DEVSEL timing is guaranteed by design when used as inputs.
4. PCI_PERR and PCI_GNT are guaranteed by design.
5. Guaranteed by design.
36-00-00-000
Ver. 1.3.1
34
Aeroflex Microelectronics Solutions - HiRel
PCI_CLK
t17
All Outputs
t18
t19
Bi-Direct and
Tri-State Outputs
t21
t20
All Inputs
Figure 10. PCI Timing Diagram
SYSCLK
PCI_CLK
t23a
t23b
PCI_RST
t22
RESET
t24
Bi-Direct and
Tri-State Outputs
Figure 11. Timing Relationships of Clock and Reset for PCI Core Utilization
SYSCLK
PCI_CLK
t22
RESET
PCI_RST
Figure 12. Timing Relationships of Clock and Reset for Unused PCI Core
36-00-00-000
Ver. 1.3.1
35
Aeroflex Microelectronics Solutions - HiRel
4.7 Timing Characteristics for Ethernet Interface
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
Min
Max
Units
ETX_CLK↑ to output valid
(ETXD[3:0], and ETX_EN)
--
12
ns
t262,3
Setup time to ERX_CLK↑
(ERX_DV, ERX_ER, and ERXD[3:0])
1
--
ns
t272,3
Hold time from ERX_CLK↑
(ERX_DV, ERX_ER, and ERXD[3:0])
1
--
ns
t251
Description
Conditions
t281
EMDC↑ to output valid (EMDIO)
-4+tAMBA4
4+tAMBA4
ns
t295
Setup time to EMDC↑ (EMDIO)
10
--
ns
t305
Hold time from EMDC↑ (EMDIO)
10
--
ns
Notes:
1. All outputs are measured using the load conditions shown in Figure 17.
2. ERX_ER timing is guaranteed by design.
3. ERX_COL and ERX_CRS are asynchronous inputs and are not tested.
4. tAMBA is defined as tSYSCLK for NODIV = 1 and tSYSCLK * 2 for NODIV = 0.
5. Guaranteed by design.
ETX_CLK
t25
All Outputs
ERX_CLK
t26
t27
All Inputs
Figure 13. Ethernet Transmit and Receive Timing
EMDC
t28
EMDIO (Output)
t29
t30
EMDIO (Input)
Figure 14. Ethernet MDIO Interface Timing
36-00-00-000
Ver. 1.3.1
36
Aeroflex Microelectronics Solutions - HiRel
4.7 Timing Characteristics for MIL-STD-1553 Interface2
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
t311
Description
Conditions
1553CLK↑ to output valid
(1553RXENA, 1553RXENB, 1553TXINHA, 1553TXINHB, 1553TXA,
1553TXA, 1553TXB, and 1553TXB)
Min
Max
Units
--
20
ns
Notes:
1. All outputs are measured using the load conditions shown in Figure 17.
2. The 1553RXA, 1553RXA, 1553RXB and 1553RXB inputs are resynchronized internally.
1553CLK
t31
All Outputs
Figure 15. MIL-STD-1553 Interface Timing
36-00-00-000
Ver. 1.3.1
37
Aeroflex Microelectronics Solutions - HiRel
4.7 Timing Characteristics for SPI2
(VDD = 3.3V + 0.3V; VDDC = 1.2V + 0.1V; TC = -55oC to 105oC)
Symbol
t321
Description
Conditions
SPICLK↑ to output valid
(SPIMOSI)
Min
Max
Units
-2
2
ns
Notes:
1. All outputs are measured using the load conditions shown in Figure 17.
2. The SPIMISO input is resynchronized internally.
SPICLK
t32
t32
SPIMOSI
Figure 16. Serial Peripheral Interface (SPI) Timing
36-00-00-000
Ver. 1.3.1
38
Aeroflex Microelectronics Solutions - HiRel
4.8 Test Conditions for Timing Specifications
VDD
VDD
100
100
CL
Figure 17. Equivalent Load Circuit for Timing Characteristics Tests
CL = 50 pF for ATE test load
CL =15 pF for benchtop test load
36-00-00-000
Ver. 1.3.1
39
Aeroflex Microelectronics Solutions - HiRel
5.0 Packaging
Figure 18. 484-lead Ceramic Land Grid Array
36-00-00-000
Ver. 1.3.1
40
Aeroflex Microelectronics Solutions - HiRel
Figure 19. 484-lead Ceramic Column Grid Array
36-00-00-000
Ver. 1.3.1
41
Aeroflex Microelectronics Solutions - HiRel
Figure 20. 484-lead Ceramic Ball Grid Array
36-00-00-000
Ver. 1.3.1
42
Aeroflex Microelectronics Solutions - HiRel
7.0 Ordering Information
UT700 LEON 3FT
UT700 -
*
*
*
Lead Finish: (NOTE 1)
(C) = Gold
(A) = Hot Solder Dipped or Tinned
Screening Level: (NOTE 2 & 3)
(P) = Prototype (Temperature Range: 25oC only)
(E) = HiRel (Temperature Range: -55oC to +105oC)
Case Outline:
(Z) = 484-Ceramic Land Grid Array
(S) = 484-Ceramic Column Grid Array
(C) = 484-Ceramic Ball Grid Array
UT700 32-bit LEON 3FT
Notes:
1. Lead finish (A or C) must be specified.
2. Prototype Flow per Aeroflex Manufacturing Flows Document. Devices are tested at 25oC only. Radiation is neither tested nor guaranteed.
3. HiRel Flow per Aeroflex Manufacturing Flows Document. Radiation is neither tested nor guaranteed.
36-00-00-000
Ver. 1.3.1
Package Option
Associated Lead Finish
(Z) 484-CLGA
(C) Gold
(S) 484-CCGA
(A) Hot Solder Dipped
(C) 484-CBGA
(A) Hot Solder Dipped
43
Aeroflex Microelectronics Solutions - HiRel
UT700 LEON 3FT: SMD
5962
*
13238
**
*
*
*
Lead Finish: (NOTE 1)
(C) = Gold
(F) = Solder
Case Outline:
(X) = 484-Ceramic Land Grid Array Package
(Y) = 484-Ceramic Column Grid Array
Screening Level:
(Q) = QML Class Q
Device Type: (NOTE 2)
(01) = UT700 (Temperature range: -55oC to +105oC)
(02) = UT700 Assembled to Aeroflex’s Q+ Flow (Temp range: -55oC to +105oC)
Drawing Number:
13238
Total Dose:
(R) = 1E5 rad(Si)
Federal Stock Class Number: No Options
Notes:
1. Lead finish is “C” (gold) only.
2.Aeroflex’s Q+ assembly flow, as defined in section 4.2.2.d of the SMD, provides QML-Q product through the SMD that is manufactured with Aeroflex’s standard QML-V flow, and has completed QML-V qualification per MIL-PRF-38535.
36-00-00-000
Ver. 1.3.1
44
Aeroflex Microelectronics Solutions - HiRel
Aeroflex Colorado Springs - Datasheet Definition
Advanced Datasheet - Product In Development
Preliminary Datasheet - Shipping Prototype
Datasheet - Shipping QML & Reduced Hi-Rel
This product is controlled for export under the Export Administration Regulations (EAR). A
license from the U.S. Government is required prior to the export of this product from the United States.
www.aeroflex.com
[email protected]
Aeroflex Colorado Springs, Inc., reserves the right to
make changes to any products and services described
herein at any time without notice. Consult Aeroflex or an
authorized sales representative to verify that the
information in this data sheet is current before using this
product. Aeroflex does not assume any responsibility or
liability arising out of the application or use of any product
or service described herein, except as expressly agreed to
in writing by Aeroflex; nor does the purchase, lease, or
use of a product or service from Aeroflex convey a license
under any patent rights, copyrights, trademark rights, or
any other of the intellectual rights of Aeroflex or of third
parties.
36-00-00-000
Ver. 1.3.1
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused
45
Aeroflex Microelectronics Solutions - HiRel
DATA SHEET REVISION HISTORY
Revision &
Date
Description of Change
11/19/13
Ver. 1.0.0
Release of Preliminary Data Sheet
8/26/14
Ver. 1.1.0
Release Production Datasheet
Page 1: Corrected SEL Immune
Page 17: Corrected VDDC, VDD limits, and note 3 temperature
Page 18: Moved Operational Environment table from section 5 to 3.3 and updated
Page 19: Added IDDCS, IDDS limits from TBD
Page 20: Added IIN and IIN limits (to bound the range for pull up/down resistors)
Page 22: Corrected tDSD limits
Page 23: Corrected IIN and IOZ limits
Page 32: Corrected symbols t14, t15, t16, and the corresponding timing diagrams
Page 39: Moved the Operational Environment table to section 3.3 on page 18
Pages 40-42: Corrected package drawings
11/21/14
1.2.0
Page 2: Changed Figure 1 Data and Instr Cache Values from 2x4kB to 4x4kB
Page 16: Added GPIO[2] entry to Bootstrap signals table.
Page 28:Re-wrote section 4.1.4
Page 43:Corrected SMD lead finish designator.
Page All: Added Footer
March 2015 Page 17: Removed note 3 and changed the maximum junction temperature value from 125°C to 150°C in the
Absolute Maximum Ratings Table.
Ver. 1.3.1
Page 26: Rewrote section 4.1.1 on power sequencing.
36-00-00-000
Ver. 1.3.1
46
Aeroflex Microelectronics Solutions - HiRel