FEATURES


Fully encapsulated Plastic Case
3 Mounting Versions:
- PCB Mounting with Solder Pins
- Chassis Mounting with Screw Terminals
- DIN-Rail Mounting

Package Dimension 88.9x67.5x34.2 mm (PCB
Mounting Version)

Universal Input 85-264VAC, 47-440 Hz

Protection Class ll

Extended Operating Temp.Range -40°C to +60°C
at full Load


LED Output Indicator (Chassis Version Models)
Industrial Safety to UL/cUL/IEC/EN 60950-1 and
UL508

Medical Safety Approval to UL/cUL/IEC/EN
60601-1 3rd Edition

Over Load Protection

3 Year Product Warranty
The new AB60S series is a range of fully encapsulated AC/DC power modules. These high performance products feature an
extended operating temperature range of -40°C to +80°C. Universal input voltage 85-264VAC and UL/IEC/EN safety approvals
including medical safety and UL508 listing qualify these power supplies modules for applications in products with worldwide
markets.EMI-filter meets EN55022, class B and FCC,part15, class B.
The AB60S series power modules provide an economical solution for many space critical applications in commercial, medical and
industrial electronic equipment.
Model Selection Guide
Model Number PCB Mounting
Output Current
Input Current
Max.
115VAC, 60Hz 230VAC, 50Hz
@Max. Load
VDC
mA
mA(typ.)
AB60S0500A
5.1
10000
880
AB60S1200A
12
5000
AB60S1500A
15
4000
AB60S2400A
24
AB60S4800A
48
DS_AB60S_06162014
Output
Voltage
Max. capacitive
Load
Efficiency
(typ.)
@Max. Load, 115VAC
μF
%
528
8000
84
1000
600
3900
87
1000
600
3300
87
2500
1000
600
1500
87
1250
988
593
680
88
E-mail: [email protected]
http://www.deltaww.com/dcdc
P1
Input Specifications
Parameter
Model
AC Voltage Input Range
Input Frequency Range
Max.
Unit
---
264
VAC
47
---
440
Hz
---
370
VDC
---
0.5
---
W
115VAC
---
---
30
A
230VAC
---
---
60
A
No-Load Power Consumption
Inrush Current (Cold Start at 25℃)
Typ.
85
120
All Models
DC Voltage Input Range
Min.
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Min.Load
Ripple & Noise
Over Voltage Protection
Temperature Coefficient
Overshoot
Current Limitation
Short Circuit Protection
Conditions
Min.
Typ.
--±1.0
Vin=Min. to Max.
--±0.2
Iout=Min. to Max.
--±0.5
No minimum Load Requirement
(5.1VDC Output Models)
--2.0
0-20 MHz Bandwidth
(Other Output Models)
--1.0
Zener diode clamp
--120
--±0.02
----85VAC, Hiccup Mode, auto-recovery
105
--(long term overload condition may cause damage)
Hiccup mode, indefinite (automatic recovery)
Max.
Unit
±2.0
±1.0
±1.0
%
%
%
3.0
1.5
----5
%VPP of Vo
%VPP of Vo
% of Vo
%/℃
%
---
%Inom.
General Specifications
Parameter
I/O Isolation Voltage (reinforced)
Leakage Current
I/O Isolation Resistance
Switching Frequency
Hold-up Time
MTBF (calculated)
Conditions
500 VDC
115VAC, 60Hz
230VAC, 50Hz
MIL-HDBK-217F@25℃, Ground
Benign
Protection Class II
Min.
Typ.
Max.
Unit
4000
--1000
-------
--80
--100
20
80
-------------
VACrms
μA
MΩ
KHz
ms
ms
125,000
---
---
Hours
According IEC/EN 60536
IEC/EN 60950-1, 60601-1 3rd, 2XMOPP
cUL/UL 60950-1, 60601-1 3rd, 2XMOPP, UL 508 listed
Safety Approvals
EMC Specifications
Parameter
Conducted and radiated EMI
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
PFMF
Dips
Interruption
DS_AB60S_06162014
Standards & Level
Performance
EN55011, EN55022, FCC part 15
EN61000-4-2 air ± 8kV , Contact ± 4kV
EN61000-4-3 10V/m
EN61000-4-4 ± 2kV
EN61000-4-5 ±1kV
EN61000-4-6 10Vrms
EN61000-4-8 30A/m
EN61000-4-11 30% 10ms
EN61000-4-11 >95% 5000ms
Class B
A
A
A
A
A
A
A
B
E-mail: [email protected]
http://www.deltaww.com/dcdc
P2
Environmental Specifications
Parameter
Temperature Range (operational)
Power Derating
Storage Temperature Range
Humidity (non condensing)
Cooling
Conditions
Min.
Max.
Ambient
Above +60℃
-40℃
+80℃
2.3W / ℃
+95℃
95% rel. H
-40℃
--Free-Air convection
Notes
1
2
3
4
5
6
7
8
9
This product is not designed for use in critical life support systems, equipment used in hazardous environment, nuclear control
systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet.
Specifications typical at Ta=+25℃, resistive load, 115VAC, 60Hz input voltage, after warm-up time rated output current unless
otherwise noted.
Safety approvals cover frequency 47-63 Hz.
We recommend to protect the converter by a slow blow fuse in the input supply line.
Other input and output voltage may be available, please contact factory.
To order the module with chassis mount package, please add a suffix C (e.g. AB60S1500C).
To order the module in chassis mount with DIN-Rail kit, please add a suffix D (e.g. AB60S1500D).
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
Specifications are subject to change without notice.
Package Specifications PCB Mounting
Mechanical Dimensions
Pin Connections
Pi
Function
n
25.4 [1.00]
6
1.0 [ 0.04]
4
1
AC (N)
2
AC (L)
4
+Vout
6
-Vout
88.9 [3.50]
17.00
[0.67]
Bottom View
81.3 [3.20]
Mounting M4 Thread
36.45
[1.44]
17.75
[0.70]
1
2
55.88 [2.20]
67.5 [2.66]
0.7 [0.03]
6.0 [0.24]
34.2 [1.35]
►All
dimensions in mm (inches)
►Tolerance:
±1.0 (±0.04)
diameter  1.0 ±0.1
(0.04±0.004)
►Pin
Physical Characteristics
Case Size
:
88.9x67.5x34.2mm (3.50x2.66x1.35 inches)
Case Material
:
Plastic resin (flammability to UL 94V-0 rated)
Pin Material
:
Copper Alloy with Gold Plate Over Nickel Subplate
Weight
:
360g
DS_AB60S_06162014
E-mail: [email protected]
http://www.deltaww.com/dcdc
P3
Package Specifications Chassis Mounting (order code suffix C)
Mechanical Dimensions
Connections
Pi
n
4x 3.5
2
5
Top View
1
4
Indication LED
67.8 [2.67]
6
50.0 [1.97]
7
3
DCON
POWER"GOOD"INDICATOR
Function
1
AC (N)
2
AC (L)
3
NC
4
+Vout
5
NC
6
-Vout
7
NC
100.0 [3.94]
112.0 [4.41]
NC: No Connection
38.0 [1.50]
5.0[0.20]
11.0 [0.43]
16.8 [0.66]
90.0 [3.54]
►All
dimensions in mm (inches)
►Tolerance:
±1.0 (±0.04)
Physical Characteristics
Case Size
:
112.0x67.8x38.0mm (4.41x2.67x1.50 inches)
Case Material
:
Plastic resin (flammability to UL 94V-0 rated)
Weight
:
380g
Package Specifications with DIN Rail Mounting Bracket (order code suffix D)
Mechanical Dimensions
4x
3.5
2
Top View
1
67.8 [2.67]
5
4
50.0 [1.97]
7
6
3
Indication LED
DCON
POWER"GOOD"INDICATOR
100.0 [3.94]
112.0 [4.41]
DS_AB60S_06162014
38.0 [1.50]
11.0 [0.43]
3.0 [0.12]
5.0[0.20]
11.0 [0.43]
16.8 [0.66]
90.0 [3.54]
E-mail: [email protected]
http://www.deltaww.com/dcdc
P4
Physical Characteristics
Case Size
:
112.0x67.8x38.0mm (4.41x2.67x1.50 inches)
Case Material
:
Plastic resin (flammability to UL 94V-0 rated)
Weight
:
433g
DIN-Rail Mounting Bracket
Part Numbering System
A
B
60
S
05
00
A
Product type
Family series
Watt
Number of
Outputs
Output
Voltage I
Output
Voltage II
Option Code
AC/DC Power Module
Medical
application
60 – 60W
S - Single
05 - 5.1V
00 - not
applicable
12 - 12V
15 - 15V
24 - 24V
48 - 48V
A - PCB Mount
C - Chassis Mount
D - Din Rail Mount
CONTACT: www.deltaww.com/dcdc
USA:
Telephone:
East Coast: 978-656-3993
West Coast: 510-668-5100
Fax: (978) 656 3964
Email: [email protected]
Europe:
Phone: +31-20-655-0967
Fax: +31-20-655-0999
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107
ext 6220~6224
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a three(3) years limited warranty. Complete warranty information is listed on our web site or is available upon request
from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor
for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice
DS_AB60S_06162014
E-mail: [email protected]
http://www.deltaww.com/dcdc
P5