GaAs MMIC DBS 4X2 IF SWITCH UPG183GR OUTLINE DIMENSIONS (Units in mm) D FEATURES • FOUR INDEPENDENT IF CHANNELS 16 pin HTSSOP • INTEGRAL SWITCHING TO CHANNEL INPUT TO EITHER CHANNEL OUTPUT 0.20±0.10 UE 6.4±0.3 • INSERTION LOSS PER CHANNEL: 7 dB TYP (ZO = 50 Ω) 8 9 0.65±0.1 • FREQUENCY RANGE: 950 MHz to 2150 MHz 5.5±0.3 0.20±0.10 N • CHANNEL TO CHANNEL ISOLATION: 26.5 dB TYP 16 • SMALL 16 PIN HTSSOP PACKAGE 1 IN 5.2±0.2 DESCRIPTION SC O NT NEC's UPG183GR is intended for use in Direct Broadcast Satellite (DBS) applications within the Low Noise Block (LNB) down converter, for systems where at least two LNB outputs are required. It offers four intermediate frequency amplifier channels that can independently select 1 of 4 IF inputs. It is housed in a very small 16 pin plastic HTSSOP package, available on tapeand-reel, easy to install and contributes to miniaturizing the systems. 0.9±0.2 0.4 0.5 1.8 2.7 0.1 2.5 1.5 ELECTRICAL CHARACTERISTICS (TA = +25°C, unless otherwise specified, VCONT1 to VCONT8 = 0/+5 V, PIN = 0 dBm, ZO = 50 Ω, Each Port) PART NUMBER PACKAGE OUTLINE SYMBOLS PARAMETERS AND CONDITIONS UPG183GR 16 pin HTSSOP UNITS MIN TYP MAX LINS 1 Insertion Loss 1, f = 0.95 GHz to 1.5 GHz dB — 7.0 9.0 LINS 2 Insertion Loss 2, f = 1.5 GHz to 2.15 GHz dB — 8.0 10.0 ∆LINS Insertion Loss Flatness, | LINS (0.95 GHz)—LINS (2.15 GHz)| dB — 1.5 3.0 ISOL 1 Channel Isolation 1, f = 0.95 GHz to 1.5 GHz dB 24 26.5 — ISOL 2 Channel Isolation 2, f = 1.5 GHz to 2.15 GHz dB 22 23.5 — RL(OUT) Output Return Loss, f = 0.95 GHz to 2.15 GHz dB 10 14 — mA — — 0.5 Control Current , VCONT = +5 V/0 V, RFoff DI ICONT 1 Notes: 1. Per one control pin. California Eastern Laboratories UPG183GR ABSOLUTE MAXIMUM RATINGS1 (TA = +25°C) VCONT1-8 PARAMETERS Total Power PIN Input Power TA TSTG RATINGS V -1.0 to +6.0 SYMBOLS Control Voltage 1-8 PTOT RECOMMENDED OPERATING CONDITIONS (TA = +25°C) UNITS Dissipation2 PARAMETERS UNITS MIN TYP MAX W 2 VCONT(H) Control Voltage (High) V +4.5 +5 +5.5 dBm + 10 VCONT(L) Control Voltage (Low) V -0.5 0 +0.5 Operating Ambient Temp. °C -40 to +85 Storage Temperature °C -65 to +150 D SYMBOLS UE Notes: 1. Operation in excess of any one of these parameters may result in permanent damage. 2. Mounted on a 50x50x1.6 mm double copper clad epoxy glass PWB, TA = +85°C. EVALUATION CIRCUIT (VCONT1 to VCONT8 = 0/+5 V, PIN = 0d Bm, ZO = 50 Ω, DC Blocking Capacitor = 51 pF) VCOUNT1, VCOUNT2, VCOUNT3, VCOUNT4, 51pF 51pF 1000 pF IN IN-A 50 Ω IN-B OUT1 51 pF 9 NT 16 1 ZO=50 Ω IN-C 51pF SC O IN-D 8 OUT2 51 pF ZO=50 Ω 50 Ω 1000 pF 51pF VCOUNT5, VCOUNT6, VCOUNT7, VCOUNT8 CHANNEL SELECT TRUTH TABLE ON CHANNEL CONTROL PIN OUT2 VCONT1 VCONT2 VCONT3 VCONT4 VCONT5 VCONT6 VCONT7 VCONT8 IN-A IN-B IN-C IN-D – – – – – – – – IN-A IN-B IN-C IN-D High High Low Low – – – – Low Low High High – – – – High Low High Low – – – – Low High Low High – – – – – – – – High High Low Low – – – – Low Low High High – – – – High Low High Low – – – – Low High Low High DI OUT1 UPG183GR TOP VIEW PIN CONNECTION AND INTERNAL BLOCK DIAGRAM PIN NO. 16 15 14 13 12 11 10 9 CONNECTION 1 IN-C 9 OUT1 2 GND 10 VCONT4 3 IN-D 11 VCONT3 4 VCONT5 12 VCONT2 5 VCONT6 13 VCONT1 6 VCONT7 14 IN-A 7 VCONT8 15 GND 8 OUT2 16 IN-B SW D CONNECTION SW UE PIN NO. 1 ORDERING INFORMATION PACKAGE QUANTITY UPG183GR-E1-A 16-pin Plastic HTSSOP Qty. 3k pcs/Reel 3 4 5 6 7 8 IN PART NUMBER 2 DI SC O NT Notes: 1. Carrier tape, 12 mm wide. Life Support Applications These NEC products are not intended for use in life support devices, appliances, or systems where the malfunction of these products can reasonably be expected to result in personal injury. The customers of CEL using or selling these products for use in such applications do so at their own risk and agree to fully indemnify CEL for all damages resulting from such improper use or sale. EXCLUSIVE NORTH AMERICAN AGENT FOR RF, MICROWAVE & OPTOELECTRONIC SEMICONDUCTORS CALIFORNIA EASTERN LABORATORIES • Headquarters • 4590 Patrick Henry Drive • Santa Clara, CA 95054-1817 • (408) 988-3500 • Telex 34-6393 • FAX (408) 988-0279 24-Hour Fax-On-Demand: 800-390-3232 (U.S. and Canada only) • Internet: http://WWW.CEL.COM DATA SUBJECT TO CHANGE WITHOUT NOTICE 02/01/2001 D 4590 Patrick Henry Drive Santa Clara, CA 95054-1817 Telephone: (408) 919-2500 Facsimile: (408) 988-0279 UE Subject: Compliance with EU Directives CEL certifies, to its knowledge, that semiconductor and laser products detailed below are compliant with the requirements of European Union (EU) Directive 2002/95/EC Restriction on Use of Hazardous Substances in electrical and electronic equipment (RoHS) and the requirements of EU Directive 2003/11/EC Restriction on Penta and Octa BDE. IN CEL Pb-free products have the same base part number with a suffix added. The suffix –A indicates that the device is Pb-free. The –AZ suffix is used to designate devices containing Pb which are exempted from the requirement of RoHS directive (*). In all cases the devices have Pb-free terminals. All devices with these suffixes meet the requirements of the RoHS directive. This status is based on CEL’s understanding of the EU Directives and knowledge of the materials that go into its products as of the date of disclosure of this information. Lead (Pb) Mercury < 1000 PPM Concentration contained in CEL devices -A Not Detected < 1000 PPM Not Detected < 100 PPM Not Detected SC O Cadmium Concentration Limit per RoHS (values are not yet fixed) NT Restricted Substance per RoHS Hexavalent Chromium < 1000 PPM Not Detected PBB < 1000 PPM Not Detected PBDE < 1000 PPM Not Detected -AZ (*) If you should have any additional questions regarding our devices and compliance to environmental standards, please do not hesitate to contact your local representative. DI Important Information and Disclaimer: Information provided by CEL on its website or in other communications concerting the substance content of its products represents knowledge and belief as of the date that it is provided. CEL bases its knowledge and belief on information provided by third parties and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. CEL has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. CEL and CEL suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall CEL’s liability arising out of such information exceed the total purchase price of the CEL part(s) at issue sold by CEL to customer on an annual basis. See CEL Terms and Conditions for additional clarification of warranties and liability. 5-226 ;