A/C Disconnects Save Money & Installation Time Two New Cooper Bussmann A/C Disconnect Models Loaded With Features & Convenience Simplify your installation and power disconnection process with a series of new Cooper Bussmann Air Conditioner Disconnects. The new fusible and non-fusible, all in one, Bussmann A/C disconnects with integrated GFCI receptacle meets NEC® ground fault requirements. The new Cooper Bussmann A/C disconnects with a pre-assembled cable whip kit includes everything needed to attach both the box and the cable to the exterior wall. With the cable whip already wired to the disconnect box, you can install the entire assembly in less than half the usual installation time. Disconnect With GFCI Receptacle: • Combines two installations into one • All GFCI units meet NEC® Ground Fault Requirements in 210.63, 210.8, 406.8(B)(1) • Provides a safe additional power source for contractors and homeowners Disconnect With Cable Whip Harness: • Reduce installation time up to 50% • Hassle-free, preassembled kit includes: • HVAC disconnect • Cable whip • Box wall mounting hardware • Whip wall mounting hardware Cooper Bussmann A/C Disconnects Also Meet Requirements For Other Single-Phase Applications Including: • Heat pumps • Swimming pools • Spas • Whirlpools • Pump houses NOTE: The 20A Ground Fault Receptacle must be wired to a separate 120V branch circuit than the pullout circuit B222-60F B222-60NF B222-60FGF Technical Specifications Cooper Bussmann Part Number Description Non-Fused B222-60NF 60A, Pull Out 60A 3 B222-60NFGF 60A, Pull Out w/ GFCI 60A B222-60NFNA 60A, Switch B222-60NF12W B222-60NF34W Part Number Disconnect Max HP Amp Rating Rating 120V 240V Wire Size Range Cu/Al 60C or 75C Enclosure Type Fuse Class Approximate Dimensions in Inches Height Width Depth 10 #14-3 NEMA 3R * 8.80 5.50 2.50 3.29 3 10 #14-3 NEMA 3R * 13.00 7.50 4.75 8.00 60A * 10 #14-3 NEMA 3R * 8.80 5.50 3.63 3.29 60A, Pull Out w/ 1/2" Cable Whip 60A* 3 10 #14-3 NEMA 3R * 14.75 12.50 4.00 6.00 60A, Pull Out w/ 3/4" Cable Whip 60A** 3 10 #14-3 NEMA 3R * 14.75 12.50 4.00 6.00 Weight lbs Fused B221-30F 30A, Pull Out 30A 1.5 3 #14-3 NEMA 3R H or R 8.80 5.50 2.50 3.29 B221-30FGF 30A, Pull Out with GFCI 30A 1.5 3 #14-3 NEMA 3R H or R 13.00 7.50 4.75 8.00 B222-60F 60A, Pull Out 60A 3 10 #14-3 NEMA 3R H or R 8.80 5.50 2.50 3.29 B222-60FGF 60A, Pull Out with GFCI 60A 3 10 #14-3 NEMA 3R H or R 13.00 7.50 4.75 8.00 Cable Whip Information Cooper Bussmann Part Number Description Non-Fused Pull Out Amp Rating Max Upstream Overcurrent Protection Device Wire Harness Diameter Ground Hot Wire Size Flexible Wire Size Conduit Length Non-Metallic Fittings ⁄2" #10 #10 6 Ft 1 - 90 Degree, 1 - Straight ⁄4" #8 #10 6 Ft 1 - 90 Degree, 1 - Straight B222-60NF12W 60A, Pull Out w/ 1/2" Cable Whip 60A 30A 1 B222-60NF34W 60A, Pull Out w/ 3/4" Cable Whip 60A 50A 3 * Upstream overcurrent protection device (OCPD) not to exceed 30 Amps. **Upstream overcurrent protection device (OCPD) not to exceed 50 Amps. Fused And Non-Fused Features: • A/C disconnects meet NEC® Code Requirements under articles 440.14 • Safety shield can be removed without tools. (not available on GFCI units) • GFCI units meet NEC® Code Requirements under articles 210.63, 210.8, and 406.8(B)(1). • Knockouts on back, bottom and both sides. • NEMA 3R rainproof enclosures. • UL Listed and CSA Certified. • Two-position pullout handle locks safety shield when in the ON position. (Not available on GF or NA units.) Pullout handle can be stored in the compartment in the off position. • Suitable for use as service entrance equipment applications when used with field installable ground bar. • Padlockable. © 2 0 0 5 C o o p e r B u s s m a n n • S t . L o u i s, M O 6 3 1 7 8 6 3 6 - 3 9 4 - 2 8 7 7 • w w w. c o o p e r b u s s m a n n . c o m Printed in USA Reorder # 3116 05-05-5M