IN-SITU ZIRCONIA OXYGEN ANALYZER DATA SHEET This oxygen analyzer is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion management and control. The analyzer system is comprised of the detector and converter coupled together as a complete system. Detector setting configuration includes the detector flow guide tube and detector sensor. The flow guide tube is inserted directly into the gas and directs gas to the sensor for measurement. The converter (ZKM) is comprised of the signal processor, input/ output and communications, display and system controls. The converter is equipped with advanced functionality such as performing the sensor diagnostics and sensor recovery function, so the detector can be used within long term stability. ZFK8, ZKM, ZTA General-use detector (ZFK8) High-temperature detector (ZTA) FEATURES 1. Gas sampling device is unnecessary For quick response, insert the detector directly into the flue Gas sampling functions such as a gas aspirator and a dehumidifier are not required. 2. Easy maintenance The sensor equipped with the detector, has unit construction, it is easy to replace. By separating the detector and the flow guide tube, filter replacement is easy. 3. More reliable than sensor diagnosis, sensor recoverable function Depending on the concentration of the measurement gas, the power of the sensor might deteriorate. The equipment includes sensor recovery function electronically, checking the deterioration status of the sensor depletion. Therefore, it has high reliability and long-lasting stability. 4. Safe and secure System detects thermocouple break for heater control on the sensor side. Safety functions of isolating power supply to the detector or isolating power via external contact input are also. 5. Easy operation The operation and setting for the converter can be performed interactively, and available as English, Japanese or Chinese for language display. <IP66> Converter (ZKM1) <IP67> Converter (ZKM2) SPECIFICATIONS General Specifications Measuring object: Oxygen in noncombustible gas Measuring method: Directly insert type zirconia system Measuring range: 0 to 2 ··· setting range at option 2 in 50 vol% O2 (in 1 vol% O2 steps) Repeatability: Within ±0.5%FS Linearity: Within ±2%FS Response time: Within 4 to 7 sec, for 90% (from calibration gas inlet) Warmup time: More than 10 min Analog output: 4 to 20mA DC (allowable load resistance less than 500W) or 0 to 1V DC (output resistance more than 100W) Power supply: Rated voltage; 100 to 120V AC (operating voltage 90 to 132V AC) 200 to 240V AC (operating voltage 190 to 264V AC) Rated frequency; 50/60Hz Power consumption: Maximum 240VA (Detector: approx. 200VA, Converter: approx. 40VA) Normal 70VA (Detector: approx. 50VA, Converter: approx. 20VA) EDSX3-137d Date Apr. 1, 2011 ZFK8, ZKM, ZTA Detector Specifications (ZFK) Measured gas temperature: Flow guide tube system; −20 to +600ºC (for general-use, corrosive gas) Ejector system; −20 to +1500ºC (for high-temperature gas) −20 to +800ºC (for general-use) Measured gas pressure: −3 to +3kPa (−306 to +306mmH2O) Flow guide tube: With or without blow-down nozzle Flange; JIS5K 65A FF (JIS5K-80AFF for high particulate gas) Insertion length; 0.3, 0.5, 0.75, 1m Ejector (general-use): Probe for guiding measured gas to detector Flange; JIS10K 65A RF Insertion length; 0.5, 0.75, 1, 1.5m (according to customer's specification) Operating temperature: −10 to +60ºC for Primary detecting element −5 to +100ºC for ejector section 125ºC or less at detector flange surface with power applied Storage temperature: Sensing element: −20 to +70ºC Ejector: −10 to +100ºC Structure: Dust/rain-proof structure(IEC IP66 equivalent) Filter: Alumina(filtering accuracy 50µm) and quartz paper Main materials of gas-contacting parts: Detector; Zirconia, SUS316, platinum Flow guide tube; SUS304 or SUS316 Ejector (general use); SUS316, SUS304 Ejector; (for high temperature) SiC, SUS316, SUS304 Calibration gas inlet: φ6mm tube join, φ1/4-inch tube join, or ball valbe (as specified) Reference air inlet (option): φ6mm tube join or φ1/4-inch tube join (as specified) Detector mounting: Horizontal plane ±45º, ambient surrounding air should be clean. Outer dimensions: (L × max. dia.) 210mm × 100mm (detector) Mass (approx.) {weight}: Detector; 1.6kg Ejector; 15kg (insertion length 1m) Flow guide tube (general-use, 1m); 5kg Finish color: Silver and SUS metallic color Ejector air inlet flow rate: 5 to 10 L/min Calibration gas flow: 1.5 to 2 L/min Blowdown air inlet pressure: 200 to 300kPa {2 to 3 kgf/cm2} Ejector exhaust gas processing: Into furnace, returned to flue Heater temperature drop alarm output (ejector): Alarm output when below 100 ºC Mechanical thermostat 2 N.O. (1a) contact, 200V AC, 2A Converter specification (ZKM) Concentration value indication: Digital indication in 4 digits Contact output signal: (1) Contact specification; 6 points, 1a 250V AC/3A or 30V DC/3A (2) Contact function; • Under maintenance • Under blowdown Note3) • Span calibration gas valve • Zero calibration gas valve • Instrument anomalies Note1) • Alarm Note2) Note1) The following Instrument errors (1) Thermocouples break (2) Sensor break (3) Temperature fault (4) Calibration fault (5) Zero/span adjustment fault (6) Output error turn the contact-ON Note2) Alarm selects just one as mentioned below (1) High (2) Low (3) Upper and Lower (4) High-high (5) Low-low, it turns ON while operating. Note3) Under blow down is available in case of option, and it turns ON while operating. Contact input signal: (1) Contact specification; 3points (the following option) ON; 0V (10mA or less), OFF; 5V (2) Contact function; • External hold • Calculation reset • Heater OFF • Blow down (option) • Inhibition of calibration • Calibration start • Range change Calibration method: (a) Manual calibration with key operation (b) Auto. calibration (option) Calibration cycle; 00 day 00 hour to 99 days 23 hours (c) All calibration Calibration gas: • Available range settings Zero gas; 0.010 to 25.00% O2 Span gas: 0.010 to 50.00% O2 • Recommended calibration gas concentration Zero gas; 0.25 to 2.0% O2 Span gas; 20.6 to 21.0% O2 (oxygen concentration in the air) Blowdown: A function for blowing out with compressed air dust that has deposited in the flow guide tube. Blowdown can be performed for a predetermined time and (option) at predetermined intervals. Blowdown cycle; 00 hour 00 minute to 99 hours 59 minutes Blowdown time; 0 minute 00 second to 0 minutes 999 seconds Output signal hold: Output signal is held during calibration, processing recoverable sensor, processing diagnosis of sensor, warm-up, PID auto tuning, under set up maintenance mode "available" and blowdown. The hold function can also be released. Valve and Flow meter (option): Selects zero or span gas during manual zero or span calibration. Mounted on the side of the converter. Communication function: RS232C (MODBUS) standard specification RS485 (MODBUS) (option) Combustion efficiency display (option): When you select this display, "rich mode display" will be simultaneously displayed. This function calculates and displays combustion efficiency from oxygen concentration and measured gas temperature. Thermocouple (R) is required for temperature measurement. Operating temperature: −20 to +55ºC Operating humidity: 95% RH or less, non condensing Storage temperature: −30 to +70ºC Storage humidity: 95% RH or less, non condensing Construction: Dust-proof, rainproof construction (corresponding to IP66 or IP67 of IEC) Material: Aluminum case Outer dimensions (H x W x D): 170 X 159 X 70mm (IP66, Bench type) 220 X 230 X 95mm (IP67) 182 X 163.5 X 70.6mm (Bench type) Mass {weight}: IP66: Approx. 2kg (excluding cable and detector) IP67: Approx. 4.5kg (excluding cable and detector) Finish color: IP66: Case: Silver Cover: Pantone Cool Gray 1C-F IP67: Munsell 6PB 3.5/10.5 (blue) Cover: Silver (case) Mounting method: Mounted flush on panel or on pipe CODE SYMBOLS (Detector) 4 5 6 7 8 ZFK 8 R 9 10 11 12 13 5 - 14 15 16 Description - 1 Cal. gas inlet For φ6mm tube (SUS) For φ1/4 inch tube (SUS) Ball valve 1 2 3 Power supply 100 to 120VAC 50/60Hz 200 to 240VAC 50/60Hz 1 3 Flow guide tube flange application None SUS304 general use SUS304 general use SUS304 general use SUS304 general use SUS316 for corrosive gas SUS316 for corrosive gas SUS316 for corrosive gas SUS316 for corrosive gas SUS316 with blow-down nozzle SUS316 with blow-down nozzle SUS316 with blow-down nozzle SUS316 with blow-down nozzle SUS316 for high particulate SUS316 for high particulate SUS316 for high particulate SUS316 for high particulate SUS316 for high particulate with cover SUS316 for high particulate with cover SUS316 for high particulate with cover SUS316 for high particulate with cover Others 0Y 0 5A3 5A5 5A7 5A1 5B3 5B5 5B7 5B1 5C3 5C5 5C7 5C1 6D3 6D5 6D7 6D1 6E3 6E5 6E7 6E1 ZZZ 750mm 1000mm Filter spec. Standard Instruction manual language Japanese English Chinese J E C 1 2 Specification name plate Standard (100 to 120V AC 50/60Hz) Standard (200 to 240V AC 50/60Hz) (Replacement Detector element) Power supply The product conforms to the requirements of the Electromagnetic compatibility Directive 89/336/EEC as detailed within the technical construction file number TZ734575. The applicable standards used to demonstrate compliance are : 500mm Reference air inlet Non For φ6mm tube (SUS) For φ1/4 inch tube (SUS) Y A B 1 Overvoltage category ; II power supply input ; I relay interfaces (IEC1010-1) External overcurrent protective device ; 10A Equipment interfaces are safety separated (SELV) 300mm 500mm 750mm 1000mm 300mm 500mm 750mm 1000mm 300mm 500mm 750mm 1000mm 300mm 500mm 750mm 1000mm 300mm Protection cover Without With Y A Electrical Safety: length Code symbols 100 to 120V AC ZFK8YY15-0Y0YY-0YY 200 to 240V AC ZFK8YY35-0Y0YY-0YY EN 55011 : 1992 CLASSA Conducted and Radiated emissions EN 50082-1 : 1992 Radiated immunity, ESD and FBT ZFK, ZKM 3 ZFK8, ZKM, ZTA (Converter) (Ejector) 1 2 3 4 5 6 7 8 Z KM 1 2 3 4 5 6 7 8 9 10 11 12 1 - Description 1 Construction IP66 IP67 Bench type 1 2 3 1 Mounting bracket None (Specify "None" when the bench type is selected) Mounting on panel surface Pipe mounting Y 1 2 Optional Functions None Combustion efficiency display function Note4) Blowdown Auto calibration Combustion efficiency indication + Blowdown Note4) Combustion efficiency indication + Auto calibration Note4) Blowdown + Auto calibration Combustion efficiency indication + Blowdown + Auto calibration Note4) Y 1 2 3 4 5 6 7 Display language Japanese English Chinese J E C Y 1 2 Option None (Specify "None" when the bench type or the auto calibration is selected) With valve With valve + flowmeter Note4) When you select this display, rich mode will be a simultaneous display. (Exclusive-special cable) 1 2 3 4 5 6 7 8 Z R Z KR 9 Description 1 - Connectable devices For ZKM K Conduit length None None None None None None None None None None None None 6m 10m Note5 15m 20m YA YB YC YD YE YF YG YH YJ YK YL YM AA BB CC DD 0 1 2 Insertion length [mm] 500 750 1000 1500 1 3 5 Power supply 100V/115V AC 50/60Hz 200V/220V AC 50/60Hz 230VAC 50/60Hz SCOPE OF DELIVERY Detector: Detector main unit × 1, Viton O ring × 1, mounting screw (M5mm × 16) × 6, thermal sticker × 1, flow guide tube (as specified) × 1, ceramic filter × 1, rainproof cover (as specified) × 1, Instruction manual × 1 Converter: Converter main unit × 1, mounting bracket set, (as specified) × 1 Accessories (AC250V 500mA T fuse × 2, AC250V 2.5A T fuse × 2), Instruction manual × 1 Ejector: Ejector main unit × 1, insertion tube × 1, M16mm nut, and washer × 4, packing × 1 Items to be prepared separately: (1) Standard gas for calibration Type ZBM NSH4-01 (up to 5% O2 range) Type ZBM NSJ4-01 (over 5% O2 range) (2) Reduction valve for standard gas (type ZBD61003) (3) Flowmeter Type; ZBD42203, 0.2 to 2L/min (for calibrating gas) Type; ZBD42403, 1 to 10L/min (for ejector) CAUTIONS Types For R thermocouple R Measured gas temperature For high temperatures (+1500°C max.) General-use (+800°C max.) B C D E Communication function RS-232C RS-485 1 2 Description 1 1 2 Output signal 4 to 20mA DC 0 to 1V DC Other B E Z Cable length 6m 10m 15m 20m 30m 40m 50m 60m 70m 80m 90m 100m 6m 10m 15m 20m Cable end treatment None One side (detector side) Both sides Note5) For connection between detector and converter, the conduit to be used should be rainproof flexible type. 4 Z T A • If combustible gas (CO, H2 etc.) exists in the measured gas, error will occur due to burning at the sensor section. The inclusion of corrosive gas (Si vapor, alkaline metal, P, Pb etc.) will shorten the life of the sensor. • When the measured gas temperature is high (+300°C or higher), the flange should be separated from the furnace wall in order to bring the detector flange surface temperature below the specified value +125°C). The flow guide should be attached in the direction in which the gas flow to the detector decreases. • When much dust is included in the gas, the flow guide tube should be attached at an inclination so that the flow goes from below to above. And the flow guide tube should be attached in the direction in which the gas flow to the detector decreases. • In the case of a refuse incinerator, automatic blow down of the flow guide should not be performed (to prevent corrosion of the flow guide tube due to drainage). Blowdown should be performed manually when change in the indication has become very little with the furnace stopped. CONFIGURATION Flow guide tube system (with valve) Rc1/4 (upper side blow port should be selected) Blow-down, 200 to 300kPa Solenoid valve (not supplied) Reduction valve (unnecessary when supply air pressure is 200 to 300kPa) Supply air 15ASGP tube equivalent or φ10/φ8 PTFE pipe or copper pipe (not supplied) 15ASGP tube equivalent or φ10/φ8 PTFE pipe or copper pipe (not supplied) Rainproof cover Flow guide tube Detector (ZFK8) AC power supply Gas temperature. 600ºC max. 6 1 3 5 2 4 *2 Ref. air Blue Sample gas outlet Red Yellow Rainproof flexible conduit. (Max. 20m) White Black White Gas temperature. 600ºC max. Flow guide tube for high particulate Sample gas outlet Converter (ZKM) 1 Gas temperature. 600ºC max. Flow guide tube for high particulate with cover 2 3 4 + O2 − + TC1 − O2 input Thermocouple input 5 6 AO + 7 φ6mm or φ1/4 inch tube for calibration gas (not supplied) Thermocouple for combustion control or FAULT 10 11 12 13 TM-1 14 ZERO GAS BLOW HEATER Blow Calibrating Fault contact gas contact contact output output output Alarm Maintenance contact Calibrating gas contact output contact output output Contact input ALARM + TC2 − DI1 DI2 DI3 DICOM 15 17 18 19 16 9 ZV Analog output 4 to 20mA DC or 0 to 1V DC *4 8 − 20 SPAN GAS MAINTE COM 21 22 23 24 25 SV 26 AC power supply PE *3 N AC L 27 28 1 2 RS232C or RS485 (option) TM-2 3 (Option) Flowmeter Valve Reduction valve (ZBD6) MEASURE ZERO Standard gas for zero point (ZBM) SPAN Reduction valve (ZBD6) Flowmeter *2 Ref. air to Detector (0.2 to 0.5L/min) (not supplied) Note: *1 Standard gas or instrumentation air can be used in place of span gas. *2 Instrument quality air or bottled air is *1 available as reference air instead of Span gas (ZBM) ambient air. *3 Protective earth. *1 Air supply *4 Connect the shield of a exclusive cable with the ground terminal in the converter. Reduction valve (unnecessary when supply air pressure is 50 to 100kPa) 5 ZFK8, ZKM, ZTA Flow guide tube system Rc1/4 (upper side blow port should be selected) Blow-down, 200 to 300kPa Reduction valve (unnecessary when supply air pressure is 200 to 300kPa) Solenoid valve (not supplied) Supply air 15ASGP tube equivalent or φ10/φ8 PTFE pipe or copper pipe (not supplied) 15ASGP tube equivalent or φ10/φ8 PTFE pipe or copper pipe (not supplied) Rainproof cover Flow guide tube Detector (ZFK8) AC power supply Gas temperature. 600ºC max. 6 1 5 3 2 4 *2 Ref. air Blue Sample gas outlet Yellow Red Rainproof flexible conduit. (Max. 20m) White Black White Gas temperature. 600ºC max. Flow guide tube for high particulate Sample gas outlet Converter (ZKM) 1 Gas temperature. 600ºC max. Flow guide tube for high particulate with cover 2 3 4 + O2 − + TC1 − O2 input Thermocouple input 5 6 AO + 7 or Thermocouple for combustion control φ6mm or φ1/4 inch tube for calibration gas (not supplied) 10 11 12 13 TM-1 14 ZERO GAS BLOW HEATER Blow Calibrating Fault contact gas contact contact output output output Alarm Maintenance contact Calibrating gas contact output contact output output Contact input ALARM + TC2 − DI1 DI2 DI3 DICOM 15 17 18 19 16 9 ZV FAULT Analog output 4 to 20mA DC or 0 to 1V DC *4 8 − 20 COM 21 22 23 AC power supply SPAN GAS MAINTE 24 25 PE *3 N AC L SV 26 27 28 1 2 RS232C or RS485 (option) TM-2 3 AC power supply Solenoid valve (not supplied) Joint Reduction valve (ZBD6) Standard gas for zero point (ZBM) Flowmeter (ZBD4) (1 to 1.5L/min) Reduction valve (unnecessary when supply air pressure is 50 to 100kPa) *2 Ref. air *1 Air supply to Detector (0.2 to 0.5L/min) (not supplied) Solenoid valve (not supplied) Note: *1 Standard gas or instrumentation air can be used in place of span gas. *2 Instrument quality air or bottled air is available as reference air instead of ambient air. *3 Protective earth. *4 Connect the shield of a exclusive cable with the ground terminal in the converter. 6 Reduction valve (ZBD6) Span point *1 Standard gas for span point (ZBM) Ejector system (with valve) Ejector (ZTA) Flowmeter (ZBD) Ejector (5 to 10L/min) Reduction valve (unnecessary when supply air pressure is 200 to 300kPa ) Joint Supply air Power supply 1 2 4 5 Gas temperature. 1500ºC max. Copper pipe φ6/φ4mm (not supplied) Heater temperature drop Alarm Solenoid valve (not supplied) Copper pipe φ10/φ8mm (not supplied) Copper pipe φ10/φ6mm (not supplied) Detector (ZFK8) 6 1 5 AC power supply 3 2 4 White Rainproof flexible conduit. (Max. 20m) Black White Bule Yellow Red 1 2 3 4 + O2 − + TC1 − O2 input Thermocouple input 5 6 AO + 7 FAULT Analog output 4 to 20mA DC or 0 to 1V DC Thermocouple for combustion control φ6mm or φ1/4 inch tube for calibration gas (not supplied) 10 11 12 13 TM-1 14 ZERO GAS BLOW HEATER Blow Calibrating Fault Heater contact gas contact contact output output output Alarm Maintenance contact Calibrating gas contact output contact output output Contact input ALARM + TC2 − DI1 DI2 DI3 DICOM 15 17 18 19 16 9 ZV or *4 8 − 20 SPAN GAS MAINTE COM 21 22 23 24 25 SV 26 AC power supply *3 PE N AC L 27 28 1 2 RS232C or RS485 (option) TM-2 3 (Option) Flowmeter Valve AC power supply Reduction valve (ZBD6) MEASURE ZERO Standard gas for zero point (ZBM) SPAN Reduction valve (ZBD6) *1 Span gas (ZBM) Flowmeter *2 Ref. air *1 Air supply to Detector (0.2 to 0.5L/min) (not supplied) Reduction valve (unnecessary when supply air pressure is 50 to 100kPa) Note: *1 Standard gas or instrumentation air can be used in place of span gas. *2 Instrument quality air or bottled air is available as reference air instead of ambient air. *3 Protective earth. *4 Connect the shield of a exclusive cable with the ground terminal in the converter. 7 ZFK8, ZKM, ZTA Ejector system Ejector (ZTA) Flowmeter (ZBD) Ejector (5 to 10L/min) Reduction valve (unnecessary when supply air pressure is 200 to 300kPa ) Joint Supply air 1 2 4 5 Gas temperature. 1500ºC max. Power supply Copper pipe φ6/φ4mm (not supplied) Heater temperature drop Alarm Solenoid valve (not supplied) Copper pipe φ10/φ8mm (not supplied) Copper pipe φ10/φ6mm (not supplied) Detector (ZFK8) 6 1 5 AC power supply 3 2 4 White Rainproof flexible conduit. (Max. 20m) Black White Bule Yellow Red 1 2 3 4 + O2 − + TC1 − O2 input Thermocouple input 5 6 AO + 7 or Thermocouple for combustion control φ6mm or φ1/4 inch tube for calibration gas (not supplied) 10 11 12 13 TM-1 14 ZERO GAS BLOW HEATER Blow Calibrating Fault contact gas contact contact output output output Alarm Maintenance contact Calibrating gas contact output contact output output Contact input ALARM + TC2 − DI1 DI2 DI3 DICOM 15 17 18 19 16 9 ZV FAULT Analog output 4 to 20mA DC or 0 to 1V DC *4 8 − 20 SPAN GAS MAINTE COM 21 23 22 24 25 AC power supply *3 PE N AC L SV 26 27 28 1 2 RS232C or RS485 (option) TM-2 3 AC power supply (1 to 1.5L/min) Joint Solenoid valve (not supplied) Reduction valve (ZBD6) Standard gas for zero point (ZBM) Flowmeter (ZBD4) Reduction valve (unnecessary when supply air pressure is 50 to 100kPa) *2 Ref. air to Detector *1 Air supply (0.2 to 0.5L/min) (not supplied) Note: *1 Standard gas or instrumentation air can be used in place of span gas. *2 Instrument quality air or bottled air is available as reference air instead of ambient air. *3 Protective earth. *4 Connect the shield of a exclusive cable with the ground terminal in the converter. 8 Solenoid valve (not supplied) Reduction valve (ZBD6) Span gas *1 Standard gas for span point (ZBM) DEVICE CONFIGURATION The device to be combined differ according to the conditions of the gas to be measured. Select the devices to be combined with reference to the following table. Measured gas Application Temperature Gas Flow General-use 600ºC or (boiler) less For corrosive 600ºC or gas (refuse DUST Device configuration Protection Note cover 5 to 20m/s Less than 0.2g/Nm3 — Less than 10g/Nm3 — 5 to 20m/s Less than 1g/Nm3 Less than 10g/Nm3 less — — incinerator) Less than 25g/Nm3 no Less than 25g/Nm3 yes General-use 800ºC or Less than Less than 1g/Nm3 — (boiler) less 1500ºC or 1m/s Less than Less than 1g/Nm3 — less 1m/s Detector type Converter Ejector type type Fuel; gas, oil ZFK8R 5- A 5 -1 Fuel: coal ZFK8R 5- C 5 -1 with blow down Included low moisture ZFK8R 5- B 5 -2 Included low moisture ZFK8R 5- C 5 ZFK8R with blow down Included high moisture ZFK8R with blow down SUS316 tube ZFK8R with blow down ZFK8R SIC tube with blow down Included low moisture ZKM ZKM — — -2 ZKM ZKM — — 5- D 6 -2 ZKM — 5- E 6 -2 ZKM — 5-0Y0 -1 ZKM ZTA2 5-0Y0 -1 ZKM ZTA1 with blow down Note (1) Dust volume is approximate value. (2) Instrument quality air or bottled air is available as reference air by selecting detector with reference air inlet. 9 ZFK8, ZKM, ZTA OUTLINE DIAGRAM (Unit:mm) Detector (ZFK8) Approx.132 φ 80 Approx.62 Approx.130 φ 67 5 6-φ 6 Temp.Proof cover (To order) Terminal box φ 85 Heater ° 60 Filter Approx.30 1 3 2 4 Black / White/ red / White/ 2-core wire Ground-wire Screw: M4 Calibration gas inlet Ref. Air inlet (to order) (To order) SUS316,for φ 6/φ 4 tube SUS316,for φ 6/φ 4 tube or 1/4 inch tube or 1/4 inch tube Exclusive Cable gland Approx.130 5 Temp.proof cover (to order) Terminal box ° 60 125.5 φ 26 φ 79 6-φ 6 φ 85 Approx.62 φ 67 Filter Calibration gas inlet Rc1/4 INT.THD. 10 Approx.100 ZFK8R 3 Ball valve Ref. air inlet (to order) SUS316,for φ 6/φ 4 tube or 1/4 inch tube Element output Ground-wire screw: M4 Exclusive cable gland Valve handle 5 6 yellow / blue 4-core wire Exclusive-special cable Approx.132 φ 80 Thermocouple 125.5 φ 26 φ 79 EXTERNAL CONNECTION DIAGRAM Sensor unit (ZFK8YY) (132.7) 3.5 20 (?17.5) (88.4) 4-φ 3.5(Mount for detector) TK4J4664R0 3 5 S- H 4 2 45° T+ S+ H 6 1 made in japan 40 45° φ 35 T- Flow guide tube 155 Approx. L 12 Approx. 20 130 67 34 Gas inlet 20 ZFK8R 5-5A3 5 7 1 6-M5 detector side Gas outlet 8–15 MTG. holes Oxygen detector 1 Code 11th 3 5 L (m) 0.3 0.5 0.75 1.0 MASS 2.7 Approx.(kg) 3.3 4.1 7 4.8 Z L= (to order) Flow guide tube (with blow-down nozzle) 155 Approx. L 18 Approx. 20 130 67 60.5 67 3 Gas inlet 6-M5 detector side ZFK8R 5-5C3 5 7 1 Gas outlet Oxygen detector Blow down air inlet Code 11th 3 L (m) 0.3 Mass 3.0 Approx.(kg) 5 7 1 Z 0.5 0.75 1.0 3.8 4.8 5.7 L= (to order) 8–15 MTG. holes 4-Rc1/4 with plug int.thd. 11 ZFK8, ZKM, ZTA Flow guide tube (for high particulate) 14 5 180 4 - Rc 1/4 with plug int thd. Blow down air inlet Select an upper port to avoid the condensation in the piping 8 - 19 MTG. hole 67 29. 5 Flange: JIS 5K80A FF ZFK MTG. position 185 Packing 5-6D3 5 7 1 800 50 ZFK8R Gas outlet 30 Code 11th 3 L (m) 0.3 Mass 4.5 Approx.(kg) 5 7 1 Z 0.5 0.75 1.0 5.6 7.0 8.3 L= (to order) 1 Z Gas flow Tube (50A SCH40) 5 14 180 Flow guide tube (for high particulate with cover) 4 - Rc 1/4 with plug int thd. Blow down air inlet 8 - 19 MTG. holes Select an upper port to avoid the condensation in the piping 67 29 .5 Flange: JIS 5K80A FF (175) ZFK MTG. position 50 Packing ZFK8R 5-6E3 5 7 1 800 (790) Gas outlet 12 Code 11th 3 L (m) 0.3 Mass 7.1 Approx.(kg) Gas flow Protection tube (65A SCH40) 30 (38) Tube (50A SCH40) 5 7 0.5 0.75 1.0 L= 9.0 11.4 13.6 (to order) Flow guide tube (for corrosive gas) 155 12 Approx. 40 Approx. L 130 3 67 67 60.5 Gas inlet ZFK8R 6-M5 detector side Gas outlet 5-5B3 5 7 1 1 Code 11th 3 L (m) 0.3 0.5 0.75 1.0 MASS 3.3 Approx.(kg) 4.5 6.1 7.6 5 7 Z L= (to order) 8- 15 MTG. holes Oxygen detector Ejector (ZTA) 4-M16 bolt Viewed from P direction 42.7 30 8 170 P Gas inlet 217 25 105 190 Approx. L 140 (JIS 10K65ARF) L [mm] 500 750 1000 1500 40 Detector (ZFK8) Ejector air outlet (Rc1/4) 35 EXTERNAL CONNECTION DAIAGRAM 1 2 AC power supply AC100/110V AC200/220V AC230V 3 4 5 Blow -down air inlet (Rc1/4) Ejector air inlet (Rc1/4) 40 50 45 Cable gland (A15C) Heater temp.drop alarm 13 ZFK8, ZKM, ZTA Converter (ZKM1) <IP66> Mounting hole 2-ø9 100 2.5 2.5 75 100 10 72 Valve (option) 170 ESC ENTER S Z Oxygen Analyzer POWER 270 MODE 55 O N M E A S U bolts M8 (option) ZKM Oxygen Analyzer 10 Calibration gas outlet (for F6 tube) 35 153 Mounting for 2B pipe For contact Input/output 62.5 Earth terminal (M4) For sensor (coupling) For F23.5/F15.8 tube Zero gas inlet (for F6 tube) Mtg. Plate For communication For output Span gas inlet (for F6 tube) For power supply Converter (ZKM2) <IP67> Mounting hole 4-F9 U bolts M8 (option) Bracket 324 72 195 59 20 Valve (option) 498 55 312 220 POWER N ENTER S ESC O MODE Z M E A S. Mounting for 2B pipe Earth terminal (M4) 230 14 5.7 Calibration gas outlet (for F6 tube) 95 95 3.2 39 U bolts M8 (option) 95 For sensor (coupling) For F23.5/F15.8 tube Zero gas inlet (for F6 tube) For sensor (coupling) For F23.5/F15.8 tube 40 For contact Input/output (G1/2) For communication (G1/2) 14 40 40 40 For power supply (G1/2) For output (G1/2) Span gas inlet (for F6 tube) Converter (ZKM1) <IP66> 2.5 2.5 75 Mounting hole 2-ø9 100 100 10 72 Valve (option) 170 ESC ENTER N S POWER 230 270 MODE O Oxygen Analyzer Z M E A S U bolts M8 (option) Flowmeter (option) ZKM Oxygen Analyzer 10 Calibration gas outlet (for F6 tube) 153 Mounting for 2B pipe (125) For contact Input/output 62.5 Earth terminal (M4) For sensor (coupling) For F23.5/F15.8 tube Mtg. Plate Zero gas inlet (for F6 tube) For communication Span gas inlet (for F6 tube) For output For power supply Converter (ZKM2) <IP67> Mounting hole 4-F9 U bolts M8 (option) Bracket 324 72 195 59 20 Valve (option) 230 498 312 220 POWER N ENTER S ESC O MODE Z M E A S Mounting for 2B pipe Flowmeter (option) 5.7 Earth terminal (M4) 230 14 Calibration gas outlet (for F6 tube) 95 95 95 39 3.2 U bolts M8 (option) 180 For sensor (coupling) For F23.5/F15.8 tube Zero gas inlet (for F6 tube) For sensor (coupling) For F23.5/F15.8 tube 40 For contact Input/output (G1/2) For communication (G1/2) 40 40 40 Span gas inlet (for F6 tube) For power supply (G1/2) For output (G1/2) 15 ZFK8, ZKM, ZTA Converter (ZKM3) <Bench type> 163.5 10 70.6 143.5 Oxygen Analyzer 50/60Hz 60VA OXYGEN TRANSM ITTER Made in Japan Fuji Electric systems Co.,Ltd. TYPE OUTPUT DC POWER AC SER. NO. MFD 172 ESC ENTER 注 意 POWER 182 MODE POWER FUSE T 0.5A 変換器へ供給する電源電圧は、接続される 検出器の電源電圧に合わせてください。 HEATER CAUTION FUSE T 2.5A Power supply must be selected the same voltage of detector. POWER ON OFF + O2 − + TC1− + AO− FAULT BLOW ZV HEATER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 ALARM MAINAC COM SV + TC2 − DI1 DI2 DI3 DIN L TENANCE COM 4-φ4.5 Mounting hole O2 sensor input EXTERNAL TERMINAL (TM1) / Terminal M3 O2 sensor thermocouple input *2 Exclusive cable Analog output 4-20mA DC or 0-1V DC 1 + O2 2 3 − + 4 TC1 − 5 + AO 6 Fault contact output 250V AC/3A 30V DC/3A 7 8 9 + 15 TC2 − DI1 16 17 Thermocouple input type R (not supplied) DI2 18 11 12 FAULT BLOW ZERO GAS 14 21 20 22 Alarm contact output 250V AC/3A 30V DC/3A Contact input Short circuit : on (Current 5mA) Open : off (Voltage 5V) HEATER SPAN GAS MAINTE DI3 DICOM 19 13 ZV ALARM Ground terminal M4 10 − or *1 O2 sensor heater power output Blow contact output 250V AC/3A 30V DC/3A 23 24 COM 25 Maintenance contact output 250V AC/3A 30V DC/3A SV 26 Calibrating gas contact output 250V AC/3A 30V DC/3A N 27 AC L 28 AC Power supply input 100 to120V AC 200 to 240V AC COMMUNICATION TERMINAL (TM2) /INSERTION TERMINAL Terminal number Remarks 1 2 3 RS232C TXD RXD GND Standard RS485 TRX+ TRX– GND Option Note 1) The heater power supply is the same as the converter power supply. Note 2) Be sure to connect the shield of the cable to the ground in the main body. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. International Sales Div Sales Group Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan http://www.fujielectric.com Phone: 81-3-5435-7280, 7281 Fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ Information in this catalog is subject to change without notice. Printed in Japan