JDL CLASS J TIME-DELAY FUSES Catalog Number JDL (1 - 600A) 600 Volts AC or Less 1 1.25 1.6 2 2.5 3 3.5 4 5 5.6 6 7 8 10 AMPERE RATINGS JDL 600V 12 40 15 45 17.5 50 20 60 25 70 30 80 35 90 JDL SPECIFICATIONS Dual-Element, Time-Delay 100 110 125 150 175 200 225 250 300 350 400 450 500 600 EDISON JDL Class J fuses are among the most current limiting time-delay fuses available. Their small physical size and high performance characteristics makes Class J fuses ideal for any space - limited application. Voltage Rating: JDL - 600VAC Ampere Rating: 1 - 600 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps 300,000 RMS Symmetrical Amps Self-Certified Current Limiting: Class J Fuse Agency Approvals: UL Listed, Class J, Guide JDDZ, File E162363 CSA Certified HRCI-J per C22.2, No. 248.8 Self-Certified DC Ratings: Voltage Rating: JDL (1-600) 300VDC Interrupting Rating: JDL 20,000 Amperes DC BENEFITS: • Space saving dimensions vs Class R. • Dual-Element construction provides superior time-delay to pass harmless motor or transformer surges. • High performance with fatigue - free cycling capabilities. • Extremely current limiting. APPLICATIONS: • Recommended for Type 2 (no damage) protection of IEC style motor starters and contactors. • Use to protect lower interrupting rating circuit breakers. • All general purpose circuits with inductive (high inrush) loads, including motor and motor branch circuits, and transformer circuits. Also suitable for lighting loads. 18 RECOMMENDED FUSEBLOCKS: Refer to page 137 in this catalog. RECOMMENDED UPGRADE: None. EDISON CROSS REFERENCE BUSSMANN GOULD LITTELFUSE JDL LPJ JTD AJT JDL CLASS J TIME-DELAY FUSES .2 AMPERE RATING 1,000 800 600 400 300 200 100 100 .1 .08 .06 200,000 .4 .3 A 2,000 60,000 80,000 100,000 1 .8 .6 4,000 3,000 30,000 40,000 2 1 20,000 4 3 10,000 8,000 6,000 6,000 8,000 10,000 TIME IN SECONDS 10 8 6 7 6 3 20,000 3,000 4,000 20 10 2,000 40 30 40,000 30,000 600 800 1,000 100 80 60 300 400 200 B 100,000 80,000 60,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS Ampere Rating 200 600A 400A 200A 225A 125A 100A 15A 20A 30A 40A 50A 60A 300 10A Cat. No. JDL (Amp) 600V 5A Cat. No. JDL (Amp) 600V 3A PEAK LET-THROUGH CURRENT CURVES 1A AVERAGE TIME/CURRENT CURVE RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILALBE PEAK (2.3 X SYMM RMS AMPS) .04 .03 4,000 3,000 AMPERE RATING 2,000 1,000 800 600 400 300 A 200,000 60,000 80,000 100,000 30,000 40,000 20,000 100 6,000 8,000 10,000 200 3,000 4,000 600A —± — — 8,000 9,000 10,000 11,100 11,800 12,500 13,270 13,820 15,000 16,000 17,270 19,270 20,600 2,000 400A — — 4,400 5,540 6,420 7,000 7,500 8,000 8,330 9,000 9,380 10,000 11,270 12,180 14,360 15,820 600 800 1,000 1,000 3,000 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 80,000 100,000 150,000 200,000 Let-Thru Current (Apparent RMS Symmetrical) JDL (600V) Fuse Ratings 15A 30A 60A 100A 200A 270 470 750 — — 370 670 1,130 1,640 2,360 450 800 1,420 1,910 2,760 550 1,000 1,730 2,450 3,520 625 1,220 1,890 2,850 4,000 700 1,330 2,120 3,090 4,400 750 1,440 2,250 3,400 5,000 800 1,530 2,370 3,650 5,140 820 1,600 2,580 3,780 5,430 900 1,640 2,670 4,000 5,640 925 1,760 2,790 4,470 6,000 1,000 1,850 3,000 4,670 6,420 1,160 2,000 3,220 5,000 7,400 1,220 2,150 3,520 5,360 7,950 1,400 2,460 4,000 6,170 9,000 1,560 2,640 4,450 7,000 10,000 100 60 50 40 30 20 15 10,000 8,000 6,000 300 400 *Prosp. S.C.C. 200 20,000 200 Current-Limiting Effects 600 400 40,000 30,000 100 RMS SYMMETRICAL CURRENT IN AMPERES B 100,000 80,000 60,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS 6,000 8,000 10,000 3,000 4,000 2,000 600 800 1,000 300 400 200 60 80 100 30 40 20 6 8 10 3 4 1 .01 2 .02 RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) *RMS Symmetrical Amperes Short-Circuit Current. NOTE: Data derived from Current Limiting Curves. DIMENSIONS Refer to JFL Section on page 20. 19