ZCPR (new) series.qxp

ZCPR Series
MOTOR START POTENTIAL RELAY
FEATURES
•
•
•
•
•
•
•
50A switching capability
SPST-NC configurations
.250” quick connect termination
ISO 9001 certified
Variety of mounting positions
UL, CUR SA11095
Non-position sensitive design*
ZCPRA6AM6
COIL
GENERAL DATA
Life Expectancy
Mechanical
Electrical
Minimum operations
7.5 x 105
5 x 105 at 16A 400VAC
2 x 105 at 35A 400VAC (break only)
1 x 105 at 50A 400VAC (break only)
Dimensions (mm)
51.2 x 46.6 x 36.5
Construction
Unsealed
Weight
approx. 110 grams
Coil Consumption
5VA
Coil Voltage
See table A & B
Coil Resistance
See table A & B
Insulation System
Class B (130oC)
Ambient Operating Temp. -20°C to 40°C
WIRING DIAGRAM
CONTACTS
Arrangement
SPST-NC
Ratings
16A (make and break), 400 VAC, cos k = 0.7 to 0.8
35A (break only), 400 VAC cos k = 0.7 to 0.8
50A (break only), 400 VAC cos k = 0.7 to 0.8
Material
Silver cadmium oxide
Resistance
< 50 milliohms at 1A 24VDC
*Except in position #3
1/22/13
ZCPR Series
MECHANICAL DATA
TAB MOUNT ZCPRZ6AM6 Shown
Outline Dimensions
PLASTIC MOUNT (Unit: mm)
5.0
7.6
28.7
36.5
51.2
9.6
16.0
5.0
10.4
5.2
23.3
3.0
2.0
46.6
PANEL MOUNT (Unit: mm)
5.0
3.7
9.4
8.0
5-Ø3.6
3.0
23.3
10.4
5.2
7.6
28.7
36.5
51.2
3.2
8.0
17.4
8.0
46.6
METAL TAB MOUNT ( Unit: mm)
5.0
45.2
28.7
51.2
23.3
10.0
10.4
5.2
3.0
7.6
36.5
4.0
6.4
46.6
UNIVERSAL BRACKET MOUNT ( Unit: mm)
45.2
28.7
23.3
10.0
46.6
10.4
5.2
7.6
50.70
4.0
6.4
1/22/13
ZCPR Series
MOTOR START POTENTIAL RELAY
PART NUMBERING SYSTEM
ZCPR
D 6AM
6
XXX
Basic Series Designation
Mounting Type/Terminal Configuration
Coil Type/P.U. & D.O. - See Table A & B
Mounting Position - See Below
Optional Customer Assign (XXX)
Part number ordering information.
MOUNTING TYPE/TERMINAL CONFIGURATION
B
D
M
P
U
X
Z
Plastic Tab and Panel Mount, 5 dual QD (2 on #4)
Plastic Tab and Panel Mount, 3 dual QD (#1, 2, and 5)
Panel Mount, 5 dual QD (2 on #4)
Panel Mount, 3 dual QD (#1, 2, and 5)
Universal Metal Bracket Mount, 5 dual QD (2 on #4)
Metal Tab Mount, 5 dual QD (2 on #4)
Metal Tab Mount, 3 dual QD (#1, 2, and 5)
*Universal Metal Bracket Mount not available in position 3
MOUNTING POSITION
*
Note: Custom mouting positions available upon request.
* Position sensitive
1/22/13
ZCPR Series
MOTOR START POTENTIAL RELAY
TABLE A - OPERATING CHARACTERISTICS AT 50 Hz
TABLE B - OPERATING CHARACTERISTICS AT 60 Hz
1/22/13