DC SOLID STATE RELAY 100 A LOAD CURRENT

SS33
DC SOLID STATE RELAY
100 A LOAD CURRENT
FEATURES
•
•
•
•
•
•
Photo isolation
MOSFET output
DC control
Low on-state resistance
Dielectric strength 2500 Vrms
RoHS compliant
GENERAL
Dielectric Strength
Insulation Resistance
Ambient Temperature
Termination
2500 Vrms min. (at 50/60 Hz, 1 min.)
1000 Mohms (at 500 VDC)
Operating: -30C (-22F) to 80C (176F)
Storage: -30C (-22F) to 100C (212F)
Screw
INPUT
Type
Control Voltage Range
Turn On Voltage
Turn Off Voltage
DC Input
3 to 32 VDC
4 to 32 VDC (with LED)
3 VDC
4 VDC (with LED)
1 VDC
OUTPUT
Voltage
30
50
100
150
200
400
500
0 to 30 VDC
0 to 50 VDC
0 to 100 VDC
0 to 200 VDC
0 to 500 VDC
Load Voltage Range
0 to 150 VDC
0 to 400 VDC
Current
50A
100A
40A
80A
20A
40A
50A
10A
40A
10A
7A
12A
Load Current Range 0.02 to 50A 0.02 to 100A 0.02 to 40A 0.02 to 80A 0.02 to 20A 0.02 to 40A 0.02 to 50A 0.02 to 10A 0.02 to 40A 0.02 to 10A 0.02 to 7A 0.02 to 12A
Max Leakage
0.1 mA
Current (Off-State)
Max Voltage Drop
0.35 V
0.64 V
1.5 V
0.6 V
1V
2.4 V
1.9V
1.5V
(On-State)
Max On-state
7mohms 3.5mohms 16mohms 8mohms 75mohms 37.5mohms 12mohms 105mohms 35mohms
0.24ohms 0.26ohms 0.125ohms
Resistance
Max Turn On Time
1 ms
0.5 ms
Max Turn Off Time
7/29/11
SS33
RELAY ORDERING DATA
SS33
D
30
D
100
M
L
MODEL
INPUT
VOLTAGE
LOAD
VOLTAGE RANGE
LOAD TYPE
LOAD
CURRENT
OUTPUT
COMPONENT
LED
INDICATOR
D: DC LOAD
7: 7 A
10: 10 A
12: 12 A
20: 20 A
40: 40 A
50: 50 A
80: 80 A
100: 100 A
M: MOSFET
Output
NIL: no LED
L: with LED
D: 3 TO 32 VDC
4 TO 32 VDC
(with LED)
30: 0 to 30 VDC
50: 0 to 50 VDC
100: 0 to 100 VDC
150: 0 to 150 VDC
200: 0 to 200 VDC
400: 0 to 400 VDC
500: 0 to 500 VDC
MECHANICAL DATA
OUTLINE DIMENSIONS
MOUNTING LAYOUT
47.5± 0.2
47.5 ± 0.2
45 ± 0.3
27.9 ± 0.1
11.8 ± 0.2
25.4 ± 0.1
WIRING DIAGRAM
Load
Source
Input
43.2 ± 0.3
Output
8.3 ± 0.3
58 ± 0.3
Dimensions in inches with metric equivalents in parentheses. Tolerance: ± .010"
INSTALLATION
PRECAUTIONS
1.
When mounting the relays side by side, provide a space equivalent to the width of a single SSR between two adjacent SSRs.
1.
2.
When mounting relays on heat sink surface, first apply a heat
conductive grease to the metal back surface of the SSR. Press
the SSR firmly onto the heat sink to ensure a good seal. Screw
the SSR down to the heat sink.
Before connecting a load that generates a high surge current,
such as a lamp load to the SSR, make sure that the SSR can
withstand the surge current of the load.
2.
Please DO NOT use the relay beyond the parameters listed in
the data sheet.
3.
Next, wire the screw terminals and securely tighten the screws.
7/29/11