BCP030T-70

BCP030T-70
HIGH EFFICIENCY HETEROJUNCTION POWER FET (0.25µm x 300µm gate)
The BeRex BCP030T-70 is a GaAs power pHEMT in an industry standard, 70 mil. ceramic, Micro-X, low parasitic,
surface-mountable package. It’s ideally suited for applications requiring low noise with high gain and excellent PAE
over a broad frequency range of 1000 MHz to 26 GHz.
PRODUCT FEATURES
70 mil. surface-mountable ceramic package
24 dBm P1dB @12 GHz (typical)
12 dB Gain @12 GHz (typical)
0.25µm X 300µm recessed gate
RoHS-compliant/lead-free
•
•
•
•
•
APPLICATIONS
Commercial
Military / Hi-Rel.
Test & Measurement
•
•
•
A indicates the lot tracking code
3 indicates this is a BCP030T-70
ELECTRICAL CHARACTERISTIC (TUNED FOR POWER) Ta = 25° C
SYMBOLS
PARAMETER/TEST CONDITIONS
P1dB
Output Power @ P1dB (Vds = 6V, Ids = 50% Idss)
G1dB
Gain @ P1dB (Vds = 6V, Ids = 50% Idss)
PAE
PAE @ P1dB (Vds = 6V, Ids = 50% Idss)
Idss
Saturated Drain Current (Vgs = 0V, Vds = 2.0V)
Gm
Transconductance (Vds = 3V, Vgs = 50% Idss)
Vp
Pinch-off Voltage (Ids = 0.2 mA, Vds = 2V)
TEST
FREQUENCY
12 GHz
18 GHz
12 GHz
18 GHz
12 GHz
18 GHz
MIN.
TYPICAL
23.0
22.5
10.5
7.0
24.0
23.5
12.0
8.5
70
60
90
60
Max
dBm
dB
%
120
120
-2.5
-1.1
UNIT
mA
mS
-0.5
V
BVgd
Drain Breakdown Voltage (Ig = 0.2 mA, source open)
-15
V
BVgs
Source Breakdown Voltage (Ig = 0.2 mA, drain open)
-13
V
Rth
Thermal Resistance
320
° C/W
www.berex.com
BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2015
Rev. 1.3
January 2015
NOT RECOMMENDED FOR NEW DESIGNS
BCP030T-70
ELECTRICAL CHARACTERISTIC (TUNED FOR GAIN) Ta = 25° C
SYMBOLS
PARAMETER/TEST CONDITIONS
P1dB
Output Power @ P1dB (Vds = 6V, Ids = 50% Idss)
G1dB
Gain @ P1dB (Vds = 6V, Ids = 50% Idss)
PAE
PAE @ P1dB (Vds = 6V, Ids = 50% Idss)
Idss
Saturated Drain Current (Vgs = 0V, Vds = 1.0V)
Gm
Transconductance (Vds = 3V, Vgs = 50% Idss)
Vp
Pinch-off Voltage (Ids = 0.2 mA, Vds = 2V)
TEST
FREQUENCY
12 GHz
18 GHz
12 GHz
18 GHz
12 GHz
18 GHz
MIN.
TYPICAL
21.0
19.5
11.5
8.5
22.0
20.5
13.0
10.0
65
40
90
60
MAX.
UNIT
dBm
dB
%
120
mA
120
-2.5
-1.1
mS
-0.5
V
BVgd
Drain Breakdown Voltage (Ig = 0.2mA, source open)
-15
V
BVgs
Source Breakdown Voltage (Ig = 0.2mA, drain open)
-13
V
Rth
Thermal Resistance
320
° C/W
MAXIMUM RATING (Ta = 25° C)
SYMBOLS
Vds
Vgs
Ids
Igsf
Pin
Tch
Tstg
Pt
PARAMETERS
Drain-Source Voltage
Gate-Source Voltage
Drain Current
Forward Gate Current
Input Power
Channel Temperature
Storage Temperature
Total Power Dissipation
ABSOLUTE
12 V
-6 V
Idss
18 mA
22 dBm
175° C
-60° C - 150° C
420 mW
CONTINUOUS
8V
-3 V
Idss
3 mA
@ 3dB compression
150° C
-60° C - 150° C
350 mW
Exceeding any of the above Maximum Ratings will result in reduced MTTF and may cause permanent damage to the device.
www.berex.com
BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2015
Rev. 1.3
January 2015
NOT RECOMMENDED FOR NEW DESIGNS
BCP030T-70
PIN_POUT/Gain, PAE (12 GHz)
Frequency = 12GHz
Vds = 6 V, Ids = 50% Idss (Gain Tune)
Frequency = 12GHz
Vds = 6 V, Ids = 50% Idss (Power Tune)
PIN_POUT/Gain, PAE (18 GHz)
Frequency = 18GHz
Vds = 6 V, Ids = 50% Idss (Tuned for Power)
www.berex.com
Frequency = 18GHz
Vds = 6 V, Ids = 50% Idss (Tuned for Gain)
BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2015
Rev. 1.3
January 2015
NOT RECOMMENDED FOR NEW DESIGNS
BCP030T-70
S-PARAMETER (Vds = 6V, Ids = 50% Idss)
FREQ.
[GHZ]
S11
[MAG]
S11
[ANG.]
S21
[MAG]
S21
[ANG.]
S12
[MAG]
S12
[ANG.]
S22
[MAG]
S22
[ANG.]
1
0.97
-36.44
7.62
148.34
0.019
63.96
0.71
-21.45
2
0.90
-67.46
6.84
121.35
0.034
45.01
0.68
-39.50
3
0.82
-95.78
6.15
96.63
0.045
27.50
0.65
-54.83
4
0.74
-125.41
5.56
72.34
0.054
10.39
0.60
-69.56
5
0.68
-154.85
4.97
48.89
0.059
-4.58
0.56
-85.10
6
0.63
178.26
4.38
26.69
0.062
-18.02
0.54
-101.36
7
0.58
154.89
3.96
6.77
0.065
-29.24
0.54
-114.44
8
0.55
127.75
3.61
-12.25
0.068
-38.65
0.54
-120.05
9
0.53
104.20
3.39
-30.48
0.073
-48.20
0.52
-127.27
10
0.51
78.00
3.32
-49.64
0.081
-58.64
0.45
-138.50
11
0.52
48.90
3.19
-70.35
0.089
-70.65
0.37
-157.17
12
0.54
22.14
2.97
-91.64
0.095
-83.55
0.33
176.26
13
0.57
-1.26
2.73
-111.58
0.100
-95.31
0.34
157.26
14
0.58
-24.01
2.53
-130.78
0.107
-107.75
0.36
150.45
15
0.62
-47.46
2.38
-150.22
0.112
-121.53
0.32
148.96
16
0.69
-70.66
2.28
-170.04
0.120
-135.53
0.20
152.45
17
0.76
-93.74
2.18
169.98
0.129
-151.58
0.03
167.92
18
0.82
-111.56
2.00
149.41
0.130
-167.71
0.13
-23.66
19
0.84
-119.05
1.78
131.52
0.123
177.97
0.21
-33.71
20
0.89
-123.28
1.57
112.15
0.119
163.47
0.17
-62.80
21
0.92
-128.87
1.33
91.48
0.110
145.63
0.19
-143.94
22
0.92
-151.02
1.10
69.08
0.099
126.72
0.41
-163.08
23
0.91
169.76
0.94
47.99
0.092
107.48
0.59
-145.80
24
0.93
131.71
0.82
29.94
0.086
91.39
0.66
-126.41
25
0.98
109.36
0.81
12.15
0.091
76.80
0.62
-125.11
26
1.03
107.39
0.84
-10.05
0.104
56.98
0.50
-162.86
www.berex.com
BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2015
Rev. 1.3
January 2015
NOT RECOMMENDED FOR NEW DESIGNS
BCP030T-70
Package Outline Dimension
Suggested PCB layout
All dimensions in Inches
www.berex.com
BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2015
Rev. 1.3
January 2015
NOT RECOMMENDED FOR NEW DESIGNS
BCP030T-70
Tape and Reel Dimensions
User Direction of Feed
Dimensions in mm
www.berex.com
BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2015
Rev. 1.3
January 2015
NOT RECOMMENDED FOR NEW DESIGNS
BCP030T-70
DISCLAIMER
BEREX RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO
IMPROVE RELIABILITY, FUNCTION OR DESIGN. BEREX DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE
APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN.
LIFE SUPPORT POLICY
BEREX PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES
WITHOUT THE EXPRESS WRITTEN APPROVAL OF BEREX.
1. Life support devices or systems are devices or systems which (a) are intended for surgical implant into the
body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with
instructions for use provided in labeling, can be reasonably expected to result in significant injury to the
user.
2. A critical component is any component of a life support device or system whose failure to perform can be
reasonably expected to cause the failure of the life support device or system, or to affect its safety or
effectiveness.
www.berex.com
BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2015
Rev. 1.3
January 2015
NOT RECOMMENDED FOR NEW DESIGNS