BCP030T-70 HIGH EFFICIENCY HETEROJUNCTION POWER FET (0.25µm x 300µm gate) The BeRex BCP030T-70 is a GaAs power pHEMT in an industry standard, 70 mil. ceramic, Micro-X, low parasitic, surface-mountable package. It’s ideally suited for applications requiring low noise with high gain and excellent PAE over a broad frequency range of 1000 MHz to 26 GHz. PRODUCT FEATURES 70 mil. surface-mountable ceramic package 24 dBm P1dB @12 GHz (typical) 12 dB Gain @12 GHz (typical) 0.25µm X 300µm recessed gate RoHS-compliant/lead-free • • • • • APPLICATIONS Commercial Military / Hi-Rel. Test & Measurement • • • A indicates the lot tracking code 3 indicates this is a BCP030T-70 ELECTRICAL CHARACTERISTIC (TUNED FOR POWER) Ta = 25° C SYMBOLS PARAMETER/TEST CONDITIONS P1dB Output Power @ P1dB (Vds = 6V, Ids = 50% Idss) G1dB Gain @ P1dB (Vds = 6V, Ids = 50% Idss) PAE PAE @ P1dB (Vds = 6V, Ids = 50% Idss) Idss Saturated Drain Current (Vgs = 0V, Vds = 2.0V) Gm Transconductance (Vds = 3V, Vgs = 50% Idss) Vp Pinch-off Voltage (Ids = 0.2 mA, Vds = 2V) TEST FREQUENCY 12 GHz 18 GHz 12 GHz 18 GHz 12 GHz 18 GHz MIN. TYPICAL 23.0 22.5 10.5 7.0 24.0 23.5 12.0 8.5 70 60 90 60 Max dBm dB % 120 120 -2.5 -1.1 UNIT mA mS -0.5 V BVgd Drain Breakdown Voltage (Ig = 0.2 mA, source open) -15 V BVgs Source Breakdown Voltage (Ig = 0.2 mA, drain open) -13 V Rth Thermal Resistance 320 ° C/W www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.3 January 2015 NOT RECOMMENDED FOR NEW DESIGNS BCP030T-70 ELECTRICAL CHARACTERISTIC (TUNED FOR GAIN) Ta = 25° C SYMBOLS PARAMETER/TEST CONDITIONS P1dB Output Power @ P1dB (Vds = 6V, Ids = 50% Idss) G1dB Gain @ P1dB (Vds = 6V, Ids = 50% Idss) PAE PAE @ P1dB (Vds = 6V, Ids = 50% Idss) Idss Saturated Drain Current (Vgs = 0V, Vds = 1.0V) Gm Transconductance (Vds = 3V, Vgs = 50% Idss) Vp Pinch-off Voltage (Ids = 0.2 mA, Vds = 2V) TEST FREQUENCY 12 GHz 18 GHz 12 GHz 18 GHz 12 GHz 18 GHz MIN. TYPICAL 21.0 19.5 11.5 8.5 22.0 20.5 13.0 10.0 65 40 90 60 MAX. UNIT dBm dB % 120 mA 120 -2.5 -1.1 mS -0.5 V BVgd Drain Breakdown Voltage (Ig = 0.2mA, source open) -15 V BVgs Source Breakdown Voltage (Ig = 0.2mA, drain open) -13 V Rth Thermal Resistance 320 ° C/W MAXIMUM RATING (Ta = 25° C) SYMBOLS Vds Vgs Ids Igsf Pin Tch Tstg Pt PARAMETERS Drain-Source Voltage Gate-Source Voltage Drain Current Forward Gate Current Input Power Channel Temperature Storage Temperature Total Power Dissipation ABSOLUTE 12 V -6 V Idss 18 mA 22 dBm 175° C -60° C - 150° C 420 mW CONTINUOUS 8V -3 V Idss 3 mA @ 3dB compression 150° C -60° C - 150° C 350 mW Exceeding any of the above Maximum Ratings will result in reduced MTTF and may cause permanent damage to the device. www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.3 January 2015 NOT RECOMMENDED FOR NEW DESIGNS BCP030T-70 PIN_POUT/Gain, PAE (12 GHz) Frequency = 12GHz Vds = 6 V, Ids = 50% Idss (Gain Tune) Frequency = 12GHz Vds = 6 V, Ids = 50% Idss (Power Tune) PIN_POUT/Gain, PAE (18 GHz) Frequency = 18GHz Vds = 6 V, Ids = 50% Idss (Tuned for Power) www.berex.com Frequency = 18GHz Vds = 6 V, Ids = 50% Idss (Tuned for Gain) BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.3 January 2015 NOT RECOMMENDED FOR NEW DESIGNS BCP030T-70 S-PARAMETER (Vds = 6V, Ids = 50% Idss) FREQ. [GHZ] S11 [MAG] S11 [ANG.] S21 [MAG] S21 [ANG.] S12 [MAG] S12 [ANG.] S22 [MAG] S22 [ANG.] 1 0.97 -36.44 7.62 148.34 0.019 63.96 0.71 -21.45 2 0.90 -67.46 6.84 121.35 0.034 45.01 0.68 -39.50 3 0.82 -95.78 6.15 96.63 0.045 27.50 0.65 -54.83 4 0.74 -125.41 5.56 72.34 0.054 10.39 0.60 -69.56 5 0.68 -154.85 4.97 48.89 0.059 -4.58 0.56 -85.10 6 0.63 178.26 4.38 26.69 0.062 -18.02 0.54 -101.36 7 0.58 154.89 3.96 6.77 0.065 -29.24 0.54 -114.44 8 0.55 127.75 3.61 -12.25 0.068 -38.65 0.54 -120.05 9 0.53 104.20 3.39 -30.48 0.073 -48.20 0.52 -127.27 10 0.51 78.00 3.32 -49.64 0.081 -58.64 0.45 -138.50 11 0.52 48.90 3.19 -70.35 0.089 -70.65 0.37 -157.17 12 0.54 22.14 2.97 -91.64 0.095 -83.55 0.33 176.26 13 0.57 -1.26 2.73 -111.58 0.100 -95.31 0.34 157.26 14 0.58 -24.01 2.53 -130.78 0.107 -107.75 0.36 150.45 15 0.62 -47.46 2.38 -150.22 0.112 -121.53 0.32 148.96 16 0.69 -70.66 2.28 -170.04 0.120 -135.53 0.20 152.45 17 0.76 -93.74 2.18 169.98 0.129 -151.58 0.03 167.92 18 0.82 -111.56 2.00 149.41 0.130 -167.71 0.13 -23.66 19 0.84 -119.05 1.78 131.52 0.123 177.97 0.21 -33.71 20 0.89 -123.28 1.57 112.15 0.119 163.47 0.17 -62.80 21 0.92 -128.87 1.33 91.48 0.110 145.63 0.19 -143.94 22 0.92 -151.02 1.10 69.08 0.099 126.72 0.41 -163.08 23 0.91 169.76 0.94 47.99 0.092 107.48 0.59 -145.80 24 0.93 131.71 0.82 29.94 0.086 91.39 0.66 -126.41 25 0.98 109.36 0.81 12.15 0.091 76.80 0.62 -125.11 26 1.03 107.39 0.84 -10.05 0.104 56.98 0.50 -162.86 www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.3 January 2015 NOT RECOMMENDED FOR NEW DESIGNS BCP030T-70 Package Outline Dimension Suggested PCB layout All dimensions in Inches www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.3 January 2015 NOT RECOMMENDED FOR NEW DESIGNS BCP030T-70 Tape and Reel Dimensions User Direction of Feed Dimensions in mm www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.3 January 2015 NOT RECOMMENDED FOR NEW DESIGNS BCP030T-70 DISCLAIMER BEREX RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. BEREX DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN. LIFE SUPPORT POLICY BEREX PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES WITHOUT THE EXPRESS WRITTEN APPROVAL OF BEREX. 1. Life support devices or systems are devices or systems which (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in labeling, can be reasonably expected to result in significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.berex.com BeRex, Inc. 3350 Scot Blvd. #61-01 Santa Clara, CA 95054 tel. (408) 452-5595 Specifications are subject to change without notice. ©BeRex 2015 Rev. 1.3 January 2015 NOT RECOMMENDED FOR NEW DESIGNS