BEREX BCP060T-70

BCP060T-70
HIGH EFFICIENCY HETEROJUNCTION POWER FET (0.25µm x 600µm gate)
The BeRex BCP060T-70 is a GaAs power pHEMT in an industry standard, 70 mil. ceramic, low parasitic, surfacemountable package. It’s 0.25µm by 600 µm recessed gate architecture provides high gain, high power and
excellent PAE over a broad frequency range of 1000 MHz to 26 GHz.
PRODUCT FEATURES





70 mil. surface-mountable ceramic package
26.5 dBm P1dB @12 GHz (typical)
10.5dB Gain @ 12 GHz (typical)
70% PAE @12 GHz (typical)
RoHS-compliant/lead-free
APPLICATIONS



Commercial
Military / Hi-Rel.
Test & Measurement
ELECTRICAL CHARACTERISTIC (TUNED FOR POWER) Ta = 25° C
SYMBOLS
PARAMETER/TEST CONDITIONS
P1dB
Output Power @ P1dB (Vds = 6V, Ids = 50% Idss)
G1dB
Gain @ P1dB (Vds = 6V, Ids = 50% Idss)
PAE
PAE @ P1dB (Vds = 6V, Ids = 50% Idss)
Idss
Saturated Drain Current (Vgs = 0V, Vds = 2.0V)
Gm
Transconductance (Vds = 3V, Vgs = 50% Idss)
Vp
Pinch-off Voltage (Ids = 0.2 mA, Vds = 2V)
TEST
FREQUENCY
12 GHz
18 GHz
12 GHz
18 GHz
12 GHz
18 GHz
MIN.
TYPICAL
25.5
25.0
9.0
4.0
26.5
26.0
10.5
5.5
70
50
180
120
Max
dBm
dB
%
240
240
-2.5
-1.1
UNIT
mA
mS
-0.5
V
BVgd
Drain Breakdown Voltage (Ig = 0.2 mA, source open)
-15
V
BVgs
Source Breakdown Voltage (Ig = 0.2 mA, drain open)
-13
V
Rth
Thermal Resistance
175
° C/W
BeRex, Inc. 1735 North 1 Street #302 San Jose, CA 95112 tel. (408) 452-5595
September 2012
www.berex.com
st
Specifications are subject to change without notice. ©BeRex 2012
Rev. A
BCP060T-70
ELECTRICAL CHARACTERISTIC (TUNED FOR GAIN) Ta = 25° C
SYMBOLS
PARAMETER/TEST CONDITIONS
P1dB
Output Power @ P1dB (Vds = 8V, Ids = 50% Idss)
G1dB
Gain @ P1dB (Vds = 8V, Ids = 50% Idss)
PAE
PAE @ P1dB (Vds = 8V, Ids = 50% Idss)
Idss
Saturated Drain Current (Vgs = 0V, Vds = 1.0V)
Gm
Transconductance (Vds = 3V, Vgs = 50% Idss)
Vp
Pinch-off Voltage (Ids = 0.2 mA, Vds = 2V)
TEST
FREQUENCY
12 GHz
18 GHz
12 GHz
18 GHz
12 GHz
18 GHz
MIN.
TYPICAL
23.5
24.0
9.5
4.0
24.5
25.0
11
6.5
50
45
180
120
MAX.
dBm
dB
%
240
240
-2.5
-1.1
UNIT
mA
mS
-0.5
V
BVgd
Drain Breakdown Voltage (Ig = 0.2mA, source open)
-15
V
BVgs
Source Breakdown Voltage (Ig = 0.2mA, drain open)
-13
V
Rth
Thermal Resistance
175
° C/W
MAXIMUM RATING (Ta = 25° C)
SYMBOLS
Vds
Vgs
Ids
Igsf
Pin
Tch
Tstg
Pt
PARAMETERS
Drain-Source Voltage
Gate-Source Voltage
Drain Current
Forward Gate Current
Input Power
Channel Temperature
Storage Temperature
Total Power Dissipation
ABSOLUTE
12 V
-6 V
Idss
30 mA
25 dBm
175° C
-60° C - 150° C
770 mW
CONTINUOUS
8V
-3 V
Idss
10 mA
@ 3dB compression
150° C
-60° C - 150° C
640 mW
Exceeding any of the above Maximum Ratings will result in reduced MTTF and may cause permanent damage to the device.
www.berex.com
st
BeRex, Inc. 1735 North 1 Street #302 San Jose, CA 95112 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2012
Rev. A
September 2012
BCP060T-70
PIN_POUT/Gain, PAE (12 GHz)
Frequency = 12GHz
Vds = 6 V, Ids = 50% Idss (Power Tune)
Frequency = 12GHz
Vds = 6 V, Ids = 50% Idss (Gain Tune)
PIN_POUT/Gain, PAE (18 GHz)
Frequency = 18GHz
Vds = 6 V, Ids = 50% Idss (Tuned for Power)
www.berex.com
Frequency = 18GHz
Vds = 6 V, Ids = 50% Idss (Tuned for Gain)
st
BeRex, Inc. 1735 North 1 Street #302 San Jose, CA 95112 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2012
Rev. A
September 2012
BCP060T-70
S-PARAMETER (Vds = 6V, Ids = 50% Idss)
FREQ.
[GHZ]
S11
[MAG]
S11
[ANG.]
S21
[MAG]
S21
[ANG.]
S12
[MAG]
S12
[ANG.]
S22
[MAG]
S22
[ANG.]
1
0.90
-60.76
11.78
133.20
0.029
54.41
0.48
-36.53
2
0.78
-105.90
9.06
99.27
0.045
33.13
0.41
-59.74
3
0.68
-142.83
7.14
71.51
0.055
17.59
0.35
-76.29
4
0.62
-176.75
5.78
46.88
0.062
4.08
0.30
-91.49
5
0.61
154.54
4.79
24.72
0.067
-7.08
0.27
-108.97
6
0.59
130.07
4.06
4.18
0.073
-17.33
0.27
-126.88
7
0.57
106.73
3.58
-15.67
0.081
-28.01
0.27
-139.27
8
0.58
81.95
3.20
-35.12
0.089
-38.65
0.26
-141.79
9
0.59
60.08
2.94
-54.62
0.099
-50.49
0.21
-147.95
10
0.63
36.00
2.73
-75.51
0.111
-64.55
0.11
-169.68
11
0.68
12.41
2.47
-96.75
0.119
-79.29
0.07
98.82
12
0.72
-8.35
2.21
-117.31
0.125
-94.00
0.13
58.07
13
0.75
-27.14
2.01
-137.10
0.130
-108.47
0.14
43.21
14
0.76
-47.14
1.85
-157.75
0.140
-123.66
0.10
14.57
15
0.80
-68.43
1.68
-179.26
0.144
-141.90
0.15
-49.75
16
0.86
-90.92
1.49
159.58
0.143
-159.60
0.31
-68.95
17
0.90
-112.82
1.31
141.19
0.141
-174.96
0.45
-70.56
18
0.93
-127.84
1.16
124.88
0.138
171.07
0.53
-74.01
19
0.93
-132.78
1.04
109.39
0.128
156.10
0.53
-88.99
20
0.96
-134.05
0.91
90.24
0.121
141.47
0.51
-126.25
21
0.96
-137.60
0.72
69.33
0.104
122.78
0.60
-169.56
22
0.94
-158.04
0.55
50.76
0.086
107.35
0.75
-179.70
23
0.92
164.01
0.46
35.25
0.080
93.18
0.83
-162.41
24
0.94
127.13
0.41
21.26
0.076
80.62
0.83
-143.57
25
0.99
105.00
0.42
4.82
0.084
65.84
0.76
-146.28
26
1.03
102.73
0.44
-19.39
0.092
45.71
0.66
170.63
Package Outline Dimension
www.berex.com
st
BeRex, Inc. 1735 North 1 Street #302 San Jose, CA 95112 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2012
Rev. A
September 2012
BCP060T-70
Suggested PCB layout
All dimensions in Inches
Tape and Reel Dimensions
User Direction of Feed
Dimensions in mm
www.berex.com
st
BeRex, Inc. 1735 North 1 Street #302 San Jose, CA 95112 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2012
Rev. A
September 2012
BCP060T-70
DISCLAIMER
BEREX RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO ANY PRODUCTS HEREIN TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN. BEREX DOES NOT ASSUME ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE
OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN.
LIFE SUPPORT POLICY
BEREX PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES WITHOUT THE
EXPRESS WRITTEN APPROVAL OF BEREX.
1. Life support devices or systems are devices or systems which (a) are intended for surgical implant into the body, or (b)
support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use
provided in labeling, can be reasonably expected to result in significant injury to the user.
2. A critical component is any component of a life support device or system whose failure to perform can be reasonably
expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
www.berex.com
st
BeRex, Inc. 1735 North 1 Street #302 San Jose, CA 95112 tel. (408) 452-5595
Specifications are subject to change without notice. ©BeRex 2012
Rev. A