Type HZC -55 ºC to +125 ºC

Type HZC -55 ºC to +125 ºC
SMT Hybrid Polymer-Aluminum Electrolytic Capacitors
For filtering, Bypassing and Power Supply Decoupling with Long Life Requirements
Type HZC hybrid capacitors are a combination of solid polymer
aluminum technology with wet aluminum electrolytic
technology. This results in a surface mount capacitor with a
4,000 hour life, low leakage current, high voltage capability, very
low esr and small case sizes. They are ideal for high temperature
and high reliability PC board designs. The vertical cylindrical
cases facilitate automatic mounting and feature high reflow
soldering temperature capability. Type HZC is RoHS compliant.
Highlights
Specifications
+125 °C, Up to 4,000 Hours Load Life
Low Leakage Current
Very Low ESR and High Ripple Current
260 °C reflow soldering
Film
-
Capacitance Range
10 to 330 µF
Capacitance Tolerance
±20% @ 120 Hz/+20 °C
Rated Voltage
25, 35, 50, 63 Vdc
Leakage Current (at 20°C)
I = .01CV or 3 µA max., whichever is greater after 2 minutes
I = leakage current in µAmps
C = rated capacitance in µF
V = rated DC Working voltage in Volts
Low Temperature Characteristics (at 120 Hz)
Z(-25 ºC)/Z(+20 ºC): 2
Z(-55 ºC)/Z(+20 ºC): 2.5
Ripple Current Frequency Multiplier
Frequency
Correction Factor
120 Hz
1000 Hz
10,000 Hz
100 KHz
0.1
0.3
0.6
1
RoHS Compliant
Outline Drawing
mm
Case
Code
D
L
A
B
(± 0.5) ( ± 0.3) (± 0.2) ( ± 0.2)
H
(max.)
I
(ref.)
W
P
(ref.)
K
C
5.0
5.8
5.3
5.3
6.5
2.2
0.65 ± 0.1
1.5
0.35 +0.15/-0.20
D
6.3
5.8
6.6
6.6
7.8
2.6
0.65 ± 0.1
1.8
0.35 +0.15/-0.20
X
6.3
7.7
6.6
6.6
7.8
2.6
0.65 ± 0.1
1.8
0.35 +0.15/-0.20
F
8.0
10.2
8.3
8.3
10.0
3.4
0.90 ± 0.2
3.1
0.70 ± 0.2
G
10.0
10.2
10.3
10.3
12.0
3.5
0.90 ± 0.2
4.6
0.70 ± 0.2
Capacitor Markings
C
Voltage
Code
Voltage
Vdc
E
25
V
35
H
50
J
63
Lot, Number: Year, Line, Month
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type HZC -55 ºC to +125 ºC
SMT Hybrid Polymer-Aluminum Electrolytic Capacitors
Part Numbering System
HZC
227
M
25
F
–F
24T
Packaging
Type
Capacitance
Capacitance Tolerance
Voltage Code
Case Code
Code
227 = 220 µF
M = ±20%
25 = 25 Vdc
See Ratings Table
24 = Tape
RoHS
Compliant
Indicator
carrier
width (mm)
Film
T = Tape & Reel
Ratings
Voltage
Capacitance
Rating
(µF)
(Vdc)
CDE Part Number
MAX
DCL
(µA)
MAX
MAX
E.S.R.
Ripple Current
MAX DF @
@
@
120 Hz/20°C
100kHz/+20°C 100kHz/+125°C
(ohms)
(A rms)
D
(mm)
L
(mm)
Case
Code
QTY/reel
25 Vdc ( 32 Vdc Surge )
33
25
HZC336M025C12T-F
8.2
0.14
0.080
0.55
5.0
5.8
C
1000
56
25
HZC566M025D16T-F
14.0
0.14
0.050
0.90
6.3
5.8
D
1000
100
25
HZC107M025X16T-F
25.0
0.14
0.030
1.40
6.3
7.7
X
900
220
25
HZC227M025F24T-F
55.0
0.14
0.027
1.60
8.0
10.2
F
500
330
25
HZC337M025G24T-F
82.5
0.14
0.020
2.00
10.0
10.2
G
500
0.55
5.0
5.8
C
1000
35 Vdc ( 44 Vdc Surge )
22
35
HZC226M035C12T-F
7.7
0.12
0.100
47
35
HZC476M035D16T-F
16.4
0.12
0.060
0.90
6.3
5.8
D
1000
68
35
HZC686M035X16T-F
23.8
0.12
0.035
1.40
6.3
7.7
X
900
150
35
HZC157M035F24T-F
52.5
0.12
0.027
1.60
8.0
10.2
F
500
270
35
HZC277M035G24T-F
94.5
0.12
0.020
2.00
10.0
10.2
G
500
50 Vdc ( 63 Vdc Surge )
10
50
HZC106M050C12T-F
5.0
0.10
0.120
0.50
5.0
5.8
C
1000
22
50
HZC226M050D16T-F
11.0
0.10
0.080
0.75
6.3
5.8
D
1000
33
50
HZC336M050X16T-F
16.5
0.10
0.040
1.10
6.3
7.7
X
900
68
50
HZC686M050F24T-F
34.0
0.10
0.030
1.25
8.0
10.2
F
500
100
50
HZC107M050G24T-F
50.0
0.10
0.028
1.60
10.0
10.2
G
500
63 Vdc ( 79 Vdc Surge )
10
63
HZC106M063D16T-F
6.3
0.08
0.120
0.70
6.3
5.8
D
1000
22
63
HZC226M063X16T-F
13.8
0.08
0.080
0.90
6.3
7.7
X
900
33
63
HZC336M063F24T-F
20.7
0.08
0.040
1.10
8.0
10.2
F
500
56
63
HZC566M063G24T-F
35.2
0.08
0.030
1.40
10.0
10.2
G
500
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type HZC -55 ºC to +125 ºC
SMT Hybrid Polymer-Aluminum Electrolytic Capacitors
Load Life Test
Test
Apply the maximum rated voltage for 4,000 hrs at +125 °C with full rated ripple current. After
the test measure the capacitance, DF, DCL and ESR at +20 °C. Also measure the ESR at -40 °C and
100kHz.
∆C at 120Hz
Capacitance will be within ±30% of the initial measured value
DF at 120 Hz
DF will be ≤ 200% of the initial specified value
DCL after 2 minute charge Leakage current will be ≤ the initial specified value
ESR at 100kHz/+20 °C
ESR will be ≤ 200% of the initial specified value
Max. ESR at 100kHz/-40 °C Case Code C : 2.0 Ω; Case Code D : 1.4 Ω; Case Code X : 0.8 Ω;
after Load Life test
Case Code F : 0.4 Ω; Case Code G : 0.3 Ω
Test
Subject the capacitor to 1000 hrs at +125 °C without voltage. After the test, return the capacitor
to room temperature for two hours and then apply rated voltage for 30 minutes. The after test
measurements for capacitance, DF, DCL and ESR at +20 °C will meet the following.
∆C at 120 Hz
Capacitance will be within ±30% of the initial measured value
DF at 120 Hz
DF will be ≤ 200% of the initial specified value
DCL after 2 minute charge Leakage current will be ≤ the initial specified value
ESR at 100Khz/+20 °C
ESR will be ≤ 200% of the initial specified value
Moisture Resistance Test
Test
Subject the capacitor to 2000 hrs at +85 °C/85%RH with rated voltage. After the test, return the
capacitor to room temperature and humidity for two hours. The after test measurements for
capacitance, DF, DCL and ESR at +20 °C will meet the following.
∆C at 120 Hz
Capacitance will be within ±30% of the initial measured value
DF at 120 Hz
DF will be ≤ 200% of the initial specified value
DCL after 2 minute charge Leakage current will be ≤ the initial specified value
ESR at 100Khz/+20 °C
ESR will be ≤ 200% of the initial specified value
Temperature Cycle Test
Subject the capacitor to 1000 cycles of temperature change from -55 °C to +125 °C using the
following sequence and durations.
Test
Step
Temperature
Time at Temperature
1
-55 ºC
30 minutes
2
+20 ºC
3 minutes max
3
+125 ºC
30 minutes
4
+20 ºC
3 minutes max
After the test, return the capacitor to +20°C for one to two hours before measurement. The after
test measurements for capacitance, DF, and DCL at +20 °C will meet the following;
∆C at 120 Hz
Capacitance will be within ±20% of the initial measured value
DF at 120 Hz
DF will be ≤ 200% of the initial specified value
DCL after 2 minute charge Leakage current will be ≤ the initial specified value
Appearance
No significant change in appearance
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Film
Shelf Life Test
Type HZC -55 ºC to +125 ºC
Film
SMT Hybrid Polymer-Aluminum Electrolytic Capacitors
Reel Dimensions
mm
Case Dia.
5
6.3
8
10
W
14
18
26
26
t
3
3
3
3
Tape Dimensions
mm
Case Size Case
(mm)
Code
5 x 5.8
W ± 0.3
C
12
A ± 0.2 B +0.3/-0.2 C ± 0.5
5.7
5.7
F ± 0.1
P ± 0.1
t1
5.5
12
0.4
8.0
t2 ± 0.2 φd +0.1/-0 P1 ± 0.1 P2 ± 0.1 W1 ± 0.1
6.4
1.5
2
4
1.75
mm
Case Size
(mm)
Case Code
6.3 x 5.8
D
6.3 x 7.7
X
8 x 10.2
F
10 x 10.2
G
B +0.3/-0.2 C ± 0.5
W ± 0.3
A ± 0.2
16
7
7
8.7
8.7
12.5
10.7
10.7
14.5
24
9.0
F ± 0.1
P ± 0.1
t1
7.5
12
0.4
11.5
16
0.4
t2 ± 0.2
φd +0.1/-0
P1 ± 0.1
1.5
2
P2 ±
W1 ± 0.1
0.1
6.4
8.4
4
1.75
11
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type HZC -55 ºC to +125 ºC
SMT Hybrid Polymer-Aluminum Electrolytic Capacitors
Recommended Land Dimensions
Case Code D (mm)
mm
A
B
C
C
5
1.5
2.8
1.6
D
6.3
1.8
3.2
1.6
X
6.3
1.8
3.2
1.6
F
8
3.1
4.0
2.0
G
10
4.6
4.1
2.0
Recommended Reflow Soldering
Film
300
Peak Temperature
250
Temperature (ºC)
30 sec.
200
230°C
200°C
70 sec.
160°C
150
120 seconds
100
50
0
Case
Code
Time (sec)
Case Dia.
Peak
Time at or
(mm)
Temperature above 250 °C
C
5
D
6.3
X
6.3
F
8
G
10
Time at or
Time at or above Time at or above Number of Reflow
above 230 °C
217 °C
200 °C
Processes
2
260°C
5 seconds
30 seconds
40 seconds
70 seconds
1
Notes:
1. For 5mm and 6.3 mm case dia., if the peak temperature does not exceed 255 °C the time at or above 250 °C can increase to 10 seconds.
2. The capacitors in the 8m and 10 mm case dia. can withstand 2 reflow processes, if the peak temperature does not exceed 245 °C and the time at or above 240 °C does not exceed 10 seconds.
3. The 2nd reflow process should be performed after the capacitors have returned to room temperature.
4. Temperature should be measured with a thermal couple placed on the top surface of the capacitor.
5. After reflow soldering, the leakage current, D.F., and e.s.r., will meet the initial specifications, and the capacitance will be within ±10% of the initial measured value when measured at room conditions.
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type HZC -55 ºC to +125 ºC
SMT Hybrid Polymer-Aluminum Electrolytic Capacitors
Capacitor Temperature Characteristics
330 µF/25V
50
40
Capacitance Change (%)
30
20
10
0
-10
-20
-30
-40
Film
-50
-60
-40
-20
0
20
40
60
Temperature (°C)
80
100
120
140
0.6
D.F.
0.4
0.2
0
-60
-40
-20
0
20
100
Initial Impedance (ohms)
10
40
60
Temperature (°C)
80
100
120
140
120 Hz
1
1 kHz
0.1
10 kHz
100 kHz
0.01
-60
-40
-20
0
20
40
60
80
100
120
14010
Initial E.S.R. (ohms)
Temperature (°C)
1
120 Hz
0.1
1 kHz
10 kHz
100 kHz
0.01
-60
-40
-20
0
20
40
60
80
100
120
140
Temperature (°C)
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type HZC -55 ºC to +125 ºC
SMT Hybrid Polymer-Aluminum Electrolytic Capacitors
Capacitor Temperature Characteristics
330 µF/25V at +125 ºC with rated voltage
Life Test Results
Spec. Limit: ±30%
0
-10
-20
Film
Capacitance Change (%)
10
-30
-40
0
1000
2000
hours
3000
4000
Spec. Limit: 0.28
0.5
0.4
D.F.
0.3
0.2
0.1
0
0
1000
2000
hours
3000
Spec. Limit: 82.5 uA
100
DCL (uA)
after 2 min. at rated voltage
4000
80
60
40
20
0
0
1000
2000
hours
3000
4000
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Film
Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data
(collectively, the “Information”) in this datasheet or other publication are subject to change. The customer
is responsible for checking, confirming and verifying the extent to which the Information contained in this
datasheet or other publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without any guarantee, warranty, representation
or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based
on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has
of operating conditions that such Cornell Dubilier company regards as typical for such applications, but
are not intended to constitute any guarantee, warranty or representation regarding any such matter – and
Cornell Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning
the suitability for a specific customer application, use, storage, transportation, or operating environment.
The Information is intended for use only by customers who have the requisite experience and capability to
determine the correct products for their application. Any technical advice inferred from this Information or
otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given
gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability
for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality
and safety standards regarding the design and manufacturing of its products, in light of the current state
of the art, isolated component failures may still occur. Accordingly, customer applications which require a
high degree of reliability or safety should employ suitable designs or other safeguards (such as installation
of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the
failure of an electrical component does not result in a risk of personal injury or property damage. Although
all product-related warnings, cautions and notes must be observed, the customer should not assume that all
safety measures are indicated in such warnings, cautions and notes, or that other safety measures may not be
required.