Zinc Air ENERGIZER E13HH - Energizer Technical Information

PRODUCT DATASHEET
Asia Pacific Region
+852-31026623
ENERGIZER E13HH
Zinc Air
Specially designed for use in humid climatic conditions.
Specifications
(top view) (bottom view)
Industry Standard Dimensions
(millimeters)
Chemical System:
Tab Color:
Designation:
Nominal Voltage:
Typical Capacity:
Zinc Air (ZnO2)
Orange
IEC-PR48
1.4 Volts
280 mAh (to 0.9 volts)
(Rated at 1.5k ohms at 21°C/65% RH)
Typical Weight:
Typical Volume:
0.8 grams
0.3 cubic centimeters
Impedance
The total opposition that a battery offers to the flow of alternating
current. Impedance is a combination of resistance and reactance.
0.38
Minimum
3.00
Minimum
The typical impedance of these cells on open circuit and during
useful discharge varies from 5-20 ohms. This applies over a
frequency range of 40-5,000 hertz at the current drains shown
below.
5.40
1.35R
Typical
5.00
7.90
7.55
Impedance vs. Frequency
20
Impedance (ohms)
00% DoD
Typical Discharge Characteristics
Schedule: 16 hours/day
Typical Drain @ 1.3V:
1.3 & 0.87 milliamperes
Load: 1K & 1.5K ohms
25% DoD
50% DoD
12
80% DoD
8
4
0
1.3
0.1
1.2
1
10
100
1000
Frequency (Hz)
10000
100000
1.1
Impedance vs. Depth of Discharge
1.0
0.9
1K
0.8
0
60
25
1.5K
120
180
240
Service, Hours
300
360
Simulated Application Test
Typical Performance at 21°C & 50% RH
Schedule:
16 Hours/Day
16 Hours/Day
Typical Drains:
at 1.3V
(milliamperes)
(ohms)
Cutoff
0.9V
(hours)
1.3
0.87
1,000
1,500
215
322
Load
Impedance (ohms)
Operating Voltage
1.4
16
20
15
10
40 Hz
5
1K Hz
0
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Depth of Discharge
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 8954AP
Page 1 of 1