ENERGIZER E675HH Zinc Air - Energizer Technical Information

PRODUCT DATASHEET
Asia Pacific Region
+852‐31026623
ENERGIZER E675HH
Zinc Air
Specially designed for use in humid climatic conditions.
Specifications
(top view) (bottom view)
Industry Standard Dimensions
(millimeters)
3.80
Minimum
Chemical System:
Tab Color:
Designation:
Nominal Voltage:
Typical Capacity:
Zinc Air (ZnO2)
Blue
IEC-PR44
1.4 Volts
635 mAh (to 0.9 volts)
(Rated at 326 ohms at 21°C/65% RH)
Typical Weight:
Typical Volume:
1.9 grams
0.5 cubic centimeters
Impedance
(-)
The total opposition that a battery offers to the flow of alternating
current. Impedance is a combination of resistance and reactance.
0.25
Minimum
1.50R
Typical
4.82
4.60
The typical impedance of these cells on open circuit and during
useful discharge varies from 5-20 ohms. This applies over a
frequency range of 40-5,000 hertz at the current drains shown
below.
5.40
5.00
(+)
11.60
11.25
Impedance vs. Frequency
12
Impedance (ohms)
00% DoD
Typical Discharge Characteristics
Schedule: 16 hours/day
Typical Drain @ 1.3V:
2.1 & 1.3 milliamperes
Load: 625 & 1,000 ohms
25% DoD
8
50% DoD
80% DoD
6
4
2
0
1.3
0.1
1.2
1
10
100
1000
Frequency (Hz)
10000
100000
1.1
Impedance vs. Depth of Discharge
1.0
0.9
625
1,000
200
300
400
Service, Hours
500
0.8
0
100
25
600
Simulated Application Test
Typical Performance at 21°C & 50% RH
Schedule:
16 Hours/Day
16 Hours/Day
Typical Drains:
at 1.3V
(milliamperes)
(ohms)
Cutoff
0.9V
(hours)
2.1
1.3
625
1,000
302
488
Load
Impedance (ohms)
Operating Voltage
1.4
10
20
15
10
40 Hz
5
1K Hz
0
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Depth of Discharge
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 8956AP
Page 1 of 1