Miniature
Specifications
Industry Standard Dimensions
Chemical System:
Manganese Dioxide (MnO2)
Designation:
Nominal Voltage:
Typical Capacity:
IEC-LR41
1.5 Volts
45 mAh (to 0.9 volts)
Rated at 15K ohms / 21°C (70°F)
0.5 grams (0.02 ounces)
0.20 cubic centimeters (0.01 cubic inch)
Typical Weight:
Typical Volume:
mm (inches)
3.00 (0.118)
Minimum
3.60 (0.142)
3.30 (0.130)
7.55 (0.297)
Cross Section
3.00 (0.118) Ref.
2.70 (0.106) Ref.
R1.5 (0.059) Ref.
0.03 (0.001) Minimum Ref.
(applies to top edge of gasket or
edge of crimp, whichever is higher)
Anode Cap
Anode Gel
Gasket
Cathode Can
Separator
O
LE
0.25 (0.010) Maximum Ref.
Permissible deflection from a flat
TE
7.90 (0.311)
Cathode
Designed for electronic applications which
may require high rate pulses
BS
Typical Discharge Characteristics
Depth of Discharge Test
21°C (70°F)
Load: 15K ohms - Continuous
Typical Drain @ 1.25V: 0.083 mA
1.6
Typical closed circuit voltage during discharge
on a load of 100 ohms for 0.1 to 2.0 seconds
% Rated Capacity
O
1.5
Voltage, CCV
Percent of rated Capacity at 21°C (70°F)
1.4
1.3
1.2
0%
40%
80%
1.43V
1.10V
0.98V
Bulge Data
1.1
1.0
0.9
0
150
Schedule:
Continuous
300
Service, Hours
450
600
Typical Drains:
at 1.25V
(milliamperes)
(ohms)
Cutoff
0.9V
(hours)
0.083
15,000
542
Load
This battery will bulge as it is discharged but will not exceed the
maximum height shown on the battery drawing.
Important Notice
This data sheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 4405G