RU4DS : DAMPER DIODES - PRV : 1300 Volts Io : 2.5 Amperes

RU4DS
DAMPER DIODES
DO - 201AD
PRV : 1300 Volts
Io : 2.5 Amperes
FEATURES :
*
*
*
*
*
*
1.00 (25.4)
MIN.
0.21 (5.33)
0.19 (4.83)
High current capability
High surge current capability
High reliability
Low reverse current
Low forward voltage drop
Pb / RoHS Free
0.375 (9.53)
0.285 (7.24)
1.00 (25.4)
MIN.
0.052 (1.32)
0.048 (1.22)
MECHANICAL DATA :
* Case : DO-201AD Molded plastic
* Epoxy : UL94V-O rate flame retardant
* Lead : Axial lead solderable per MIL-STD-202,
Method 208 guaranteed
* Polarity : Color band denotes cathode end
* Mounting position : Any
* Weight : 1.16 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 °C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
RATING
SYMBOL
VALUE
UNIT
Maximum Peak Reverse Voltage
VRM
1300
V
Maximum Average Rectified Forward Current , Ta = 60 °C
IF(AV)
Peak Forward Surge Current 50 Hz
1.5
2.5 (with Heatsink)
A
IFSM
50
A
VF
1.8
V
Maximum Reverse Current at Reverse Voltage Ta = 25 °C
IR
50
µA
Maximum Reverse Current at Reverse Voltage Ta = 100 °C
IR(H)
500
µA
Trr
0.4
µs
RөJL
8.0
°C/W
Junction Temperature Range
TJ
- 40 to + 150
°C
Storage Temperature Range
TSTG
- 40 to + 150
°C
Half-cycle Sinewave Single Shot
Maximum Forward Voltage at IF = 3 A
Maximum Reverse Recovery Time ( Note 1 )
Thermal Resistance ( Junction to Lead )
Note :
( 1 ) Reverse Recovery Test Conditions : IF = 500 mA, IFP = 500 mA.
Page 1 of 2
Rev. 01 : August 24, 2005
RATING AND CHARACTERISTIC CURVES ( RU4DS )
FIG.1 - REVERSE RECOVERY TIME CHARACTERISTIC AND TEST CIRCUIT DIAGRAM
100 µF
specimen
100mA
IF
100 mA
IRP
100 Ω
20µS
0.1 IRP
200µS
Trr
NOTE : IF = IRP = 100 mA TO 10 mA
FIG.2 - DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
FIG.3 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
50
PEAK FORWARD SURGE
CURRENT, AMPERES
AVERAGE FORWARD OUTPUT
CURRENT, AMPERES
2.5
2.0
1.5
1.0
0.5
0
0
25
50 60 75
100
125
150
40
30
20
10
0
175
AMBIENT TEMPERATURE, ( °C)
1
2
4
6
10
20
40
60
100
NUMBER OF CYCLES AT 50Hz
FIG.4 - TYPICAL FORWARD CHARACTERISTICS
20
FORWARD CURRENT, AMPERES
10
1.0
0.1
Ta = 25 °C
0.01
0.001
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
FORWARD VOLTAGE, VOLTS
Page 2 of 2
Rev. 01 : August 24, 2005