Altech UL508 MA- Series Three Phase Adjustable Trip Miniature Circuit Breakers/ Manual Motor Controllers The MA was designed to handle the high inrush loads of 3 phase transformers, power supplies, motors, etc. The MA protects wiring and equipment from damage caused by the three major classes of over-current, yet greatly reduces the number of nuisance trips in high starting and inrush current circuits. An IEC device with excellent ratings under a UL listing at 480Y/277V (including group ratings) and at 500V under international standards, the Altech/ABL Sursum MA provides short and long term cost effective circuit protection for USA and/or export applications. The short term advantages include: (1) adjustable thermal trip allows finalization of initial designs before procurement of the load equipment is complete; (2) snap-on mounting for readily available, internationally standardized DIN Rail saves panel layout design time as well as installation and change labor; (3) large cage-clamp terminals with screws suitable to power screwdrivers, simplifies and speeds wiring; (4) convenient switched disconnect during factory testing and/or initial start-up saves time and aggravation. The key long term advantage is customer satisfaction and proven over-current protection of wiring and equipment (and the lack of rework/repair costs). Type and Rated Current Cat. No. MA0.16U 15.901U MA0.63U 15.904U MA0.25U MA0.40U MA1.0U MA1.6U MA2.5U MA4.0U MA6.3U MA10U MA16U Group Short Circuit Ratings (UL/CSA Ratings) see above Standard Pack and Weight 1/450g (1.0 lb.) Typical Life 15.909U 15.910U 15.911U 2.5/3.0/3.5/4.0 4.0/4.8/5.6/6.3 6.3/7.5/8.7/10 10/12/14/16 16/17/18.5/20 MA40U 15.915U 32/34/37/40 15.913U 15.914U 20/21.5/23/25 25/27/30/32 6000 on/off operations with 2xRC Calibration Temperature 25°C, +0°, -5° (77°F, +0° -9°) Terminal Size Acceptability 0.40/0.48/0.56/0.63 1.6/1.9/2.2/2.5 0.16A-2.5A: 42kA; 4.0A-16A: 14kA; 20A-40A: 10kA Standard Short Circuit Withstand Rating 0.16A-2.5A: 42kA; 4.0A-16A: 14kA (UL/CSA Ratings) 0.25/0.30/0.35/0.40 15.912U MA32U 480Y/277VAC 0.63/0.75/0.87/1.0 15.908U RT __ (d) AIC (Interrupt Capacity) 0.1/ 0.12/0.14/0.16 1.0/1.2/1.4/1.6 __ (c) Voltage Rating 15.905U 15.907U __ (b) (a) = MA - Manual Motor Controller (b) = Rated Current (c) = U - US Housing (d) = Blank - Standard Terminal RT - Ring-tongue Terminal FLA Dial Adjustment Markings MA20U MA25U MA __ (a) 0.16/0.19/0.22/0.25 15.906U CAN/CSA-C22.2 No.14 certified Type Designation 15.902U 15.903U UL508 listed E137938 GROUP SHORT CIRCUIT RATING AT 480VACa (and BCP size) 42kARMS symmetrical (max. 1200A MCCB or RK5) 14kARMS symmetrical (max. 350A MCCB or RK5) 10kARMS symmetrical (max. 350A MCCB or RK5) Top/Bottom: 18-3 AWG 3Ø HORSEPOWER RATINGS AT NOMINAL LINE VOLTAGE (See Note for HEA Definition) 110-120V HP (HEA) 200V HP (HEA) 208V HP (HEA) 220-240V HP (HEA) 460-480V HP (HEA) Through MA2.5U, ampere rated for motor circuits having a fullload-amperage (FLA) not exceeding the MAʼs general purpose rated current (RC, equals maximum dial setting) and a locked rotor current not exceeding 6 times the MAʼs RC. 1/2 (4.0) 3/4 (5.6) 1 (7.2) 2 (13.6) 5 (30.4) 3 3 5 (19.2) (19.2) (30.4) 3/4 (3.2) 3/4 11/2 (6.0) 11/2 5 (17.5) 5 2 (7.8) 3 (11.0) 5 (17.5) 71/2 (25.0) 10 (32.0) 2 (3.1) 11/2 (16.7) 5 (7.5) 3 (10.6) 71/2 (24.2) 71/2 10 1 (5.7) (24.2) (31.0) 3 (3.6) (5.2) (9.6) 2 (3.42) 3 5 (4.8) (7.6) 5 (15.2) 10 (14.0) 10 (28.0) 20 (27.0) 71/2 10 (15.2) (22.0) (28.0) 10 15 25 (14.0) (21.0) (34.0) Note: HEA - Horsepower Equivalent Amperes, the nominal amperage assigned to standard motor horsepower ratings in design guide tables such as NFPA-70 Tables 430-248, 430-249, 430-250; UL1077 Table 16.2; CSA - C22.2 No. 235-M89 Tables 44 and 45; CSA-C22.2 No. 14-M91 Table 19, etc. Multiply HEA values (in parenthesis) by 1.1 if power factor is 90%, and by 1.2 if power factor is 80%. a The standard-circuit short-circuit rating is 14kA for all types. Group ratings can be used in a standard circuit (e.g., MA1.0U at 42kA), but a higher standard rating cannot be used in a group circuit (e.g., MA40U at 14kA only in standard circuit.) 32 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com DIMENSIONS 44mm (1.73 in.) 37.5mm (1.48 in.) 120 25.5mm (1.0 in.) 60 6mm (.24 in.) 40 7mm (.28 in.) 20 Tripping time t 45mm (1.77 in.) 35mm (1.38 in.) 89.5mm (3.52 in.) 45mm (1.77 in.) Minutes 10 MA0.16U-MA16U MA 3 Phase Controller Thermal Overload (B, C, D) “Must Trip” Current = 115% of Dial Setting “Must Not Trip” > 1 hr = 105% of Dial Setting 6 4 2 1 40 20 10 6 4 2 Seconds 1 7mm (.28 in.) 0.6 0.4 Magnetic Trip Nominal 1100% of Rated Current 0.2 0.1 1 1.15 1.5 30.5mm (1.20 in.) 60 40 20 MA.16 VDE 0660 AC-3 500V 50-60Mz 12A 10A 3 14A 16A L3 40∞C 5 Tripping time t L2 Minutes 10 1 6 4 2 1 40 20 10 2 T2 4 T3 52.5mm (2.07 in.) MA/USA Manual Motor Controller 1 6 Seconds 2 MA20U-MA40U MA 3 Phase Controller Thermal Overload (B, C, D) “Must Trip” Current = 115% of Dial Setting “Must Not Trip” > 1 hr = 105% of Dial Setting 6 4 20∞C ABL SURSUM T1 16 19 120 68mm (2.68 in.) L1 4 5 6 6.9 8 10 12 Multiple of Rated Current (Magnetic Trip) Rated Current = Max. Dial Setting 3mm (.12 in.) 44mm (1.73 in.) 2 2.3 3 Multiple of Dial Setting (Thermal) 0.6 0.4 0.2 Magnetic Trip Nominal 1100% of Rated Current 0.1 11.15 1.5 2 2.3 3 4 Altech UL508 17.5mm (1.28 in.) 5 6 6.9 8 1012 15 12.5 Multiple of Dial Setting (Thermal) Multiple of Rated Current (Magnetic Trip) Rated Current = Max. Dial Setting Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 33 Altech UL508 V-EA and MA Circuit Breaker Accessories UL508 listed E137938 Accessories can be factory or field mounted on V-EA and MA manual motor controllers for enhanced control and monitoring capabilities. Field mounting kits include all necessary parts and instructions. Accessories can be gang mounted on a single controller (the Auxiliary Switch in the outside position). The mounting arrangement links the internal latch-pins for the tripping mechanisms, ensuring simultaneous trips. Handles are linked to simplify manual resetting. FA - Shunt Trip Type/ Cat. No. FA12U FA24U FA48U FA110U Trip/Coil Voltage AC or DC Max. Coil Current 12V 24V 48-72V 110V/220V Std.Pk.: 1 Unit Weight: 120 grams (0.27 lb.) Width: 17.5mm (.689in.) Approvals 1.3A 0.6A 0.2A 0.25A/0.5A UL UL UL UL UA - Undervoltage Trip (not UL listed) Type/ Cat. No. Line Voltage 60Hz* UA120 UA240 UA277 UA415 UA480 120VAC 240VAC 277VAC 415VAC 480VAC Std.Pk.: 1 Unit Weight: 70 grams (0.16 lb.) Width: 17.5mm (.689in.) H - Auxiliary Switch Type/ Cat. No. H11U Contact Rating 10A / 220V AC 3A / 110V DC or pulsed 1A / 220V DC or pulsed For further Busbar information please see pages 56-73 or our comprehensive Altech Universal Power Distribution catalog. Wire Size 4mm2 (12 AWG) Approvals For Use With: UL V-EA, MA Std. Pk.: 1 Unit Weight: 45 grams (0.12 lb.) Width: 9mm (.354in.) Lock-out ** Cat. No. EASS Prevent inadvertent resetting of the V-EA or MA during maintenance. Fits 1/4” pad lock. * Cooling Spacer Cat. No. 15.960 Please consult Altech for your 50Hz application needs. ** V-EA and MA can also be locked in the on and off position by simply using a common lead or meter seal, which gets fed through the hole in the handle and a corresponding hole in the housing. 34 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com TEMPERATURE CORRECTION CURVE Ambient Temperature and Adjacent Mounting/Loading Adjustment (V-EA/MA Ambient Temperature - 25°C to 55°C, Storage Temperature -40°C to 70°C) 160 Calibration Temperature 150 140 130 110 80 * Cooling spacer (Part #15.960) between each group of 3 poles will eliminate these adjustments. 50 -40 -40 -30 -22 -20 -4 -10 14 0 32 10 50 pol es adj ace nt m oun ted ma or ximum mo re, 20% adj ace off R nt m C fo oun r a t ted otal * off 70 60 to 3 20 68 30 86 40 104 Ambient Temperature 50 122 60 140 70 158 10 pol es 80 176 Altech UL508 up 90 40 Adjacent Mounting Temperature Adjustment 3% of RC for every additional pole above 3. Maximum 20% off RC for a total of 10 poles or more.* % 100 20 Rated Current (%) 120 Ambient Temperature Adjustment 5% of RC for every 10°C (18°F). 90 (°C) 194 (°F) Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com 35