click - Geeco

Interface Relays
I1-L General Purpose (6A 1N/O)
• Interface relay I1-L - with changeover relay, rated load 6 A / 250 V (AC1)
• 35 mm DIN rail mount, EN 50022
• Adapted for the co-operation with interconnection strip type I1-C
• Equipped in green LED
Contact data
Number and type of contacts
Contact material
Max. switching voltage
Min. switching voltage
R a te d loa d
1 C/O, SPDT
AgSnO 2
AC/DC
AC/DC
AC 1
DC1
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
Contact resistance
Max. operating frequency
• a t ra te d loa d
• no load
15 A 20 ms
AC1
≤ 100 m Ω 100 mA, 24 V
AC 1
360 cycles/hour
72 000 cycles/hour
Input control circuit
R a te d volta ge
AC: 50/60 Hz
Must release voltage
Operating range of supply voltage
Must operate voltage
Input polarization current
Rated power consumption
DC
AC/DC
DC
AC/DC
12- 24-36 V
24-42-115- 230 V
AC: ≥ 0,2 U n
AC: ≥ 0,5 U n
see Table 1
AC and DC: ≤ 0,7 U n
AC: 0,6...0,85 U n
AC: 8 mA < I p < 10 mA 230 V AC
0,3...0,7 W
0,3...1,6 VA / 0,3...1,6 W
DC:
≥ 0,1 U
DC:
≤ 0,8 U n
n
Insulation
Insulation category
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
• input - output
• input - output
• mass - input, output
• contact clearance
Input - output distance
• clearance \ creepage
C250
400 V AC
4 000 V AC
III
PN-EN
3
4 000 V AC
6 000 V AC
2 500 V AC
1 000 V AC
60664-1
50/60 Hz, 1 min.
1,2 / 50 µs, surge voltage
50/60 Hz, 1 min.
50/60 Hz, 1 min.
≥ 6 mm \ ≥ 8 mm
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive AC1
• cos φ = 0,4
• resistive DC1
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storage
• operating
Protection category
Environmental protection
7 ms
DC: 6 ms
15 ms
DC: 10 ms
> 0,6 x 10 5 6 A, 250 V AC
> 2 x 10 5
2 A, 250 V AC
10 5
6 A, 30 V DC
> 2 x 10 7
93,8 x 6,2 x 80 mm
40 g
-40...+70 oC
-40...+55 oC
-40...+40 oC 230 V AC
IP 20
RTI
PN-EN 116000-3
AC:
AC:
-40...+60
-40...+50
oC 12, 24 V DC
oC 230 V DC
The data in bold type pertain to the standard versions of the relays.
For gold-plated contacts - when the maximum values given have been
exceeded, the gold layer is destroyed. Then, the advantages of gold-plating disappear and the values are as for AgSnO 2 contacts (see beside).
In consequence however, the life of the contact may be shorter than that of the normal power contact.
Refers version I1-L-U230F - relay
with integrated anti-interference filter (desigend on the basis of appropriately selected elements R and C, and Zener diode), resistant to occurrence
of induced voltages in long distances of control wires.
35 Royal Road, Flemington, NJ 08822-6000 • (tel.) 908-806-9400 • (fax) 908-806-9490 • www.altechcorp.com
Interface Relays
I1-L General Purpose (6A 1N/O)
Input data
Cat. No.
Table 1
Interface relay code
Version with gold plated contacts.
Connections diagrams
Rated input
voltage U n
Power of input
control circuit
Input - voltage range
V
min.
max.
Version with integrated anti-interference filter.
Dimensions
I1-L-D012R, I1-L-D012G
I1-L-D024R, I1-L-D024G
I1-L-D036R, I1-L-D036G
I1-L-U024R, I1-L-U024G
I1-L-U042R
Mounting
I1-L-U110R, I1-L-U230G
I1-L-U230R
Relays I1-L are designed for 35 mm DIN rail mount,
EN 50022. Maximum size of wires 1 x 2,5 mm 2 (1 x 14
AWG). Rated contactability 2 x 1,5 mm 2 (2 x 16 AWG).
Maximum screw torgue: 0,3 Nm.
I1-L are adapted for the co-operation with interconnection strip type I1-C. I1-C bridges common input
or output signals, maximum permissible current is
36 A / 250 V AC. Colors of strips: red, black or blue.
I1-L-U230F
35 Royal Road, Flemington, NJ 08822-6000 • (tel.) 908-806-9400 • (fax) 908-806-9490 • www.altechcorp.com