Color Multi Line Sensor Heads for High-speed Scanner LSH1208-BA50A Multi Line Sensor Head with 3 times higher scanning speed due to 3ch outputs. Newly developed resolution change-over IC is employed which has improved noise resistance. zApplications High speed reading equipment (i.e. document scanners, wide format scanners). zFeatures 1) High speed reading capability due to 3 analog output. 2) Signal amplifier is built into the sensor IC in order to increase immunity to external noise. 3) ROHM’s newly developed sensor IC reduces failures due to ESD (based on the IEC61000-4-2 standard). 4) With the proprietary prism, the output signal is maintained uniformly. 5) The ceramic substrate is used for excellent dimensional accuracy and thermal stability. zDimensions (Unit : mm) 236 ±0.5 2-φ1.5×2 Oval Hole D4MIN 216 (Effective Reading Width) Effective 1st bit 9.4 0.324±0.1 17.5 14 ±0.2 Scanning Line 2-φ1.5 D4MIN 15 2- 3 +0/-0.1 2.0±0.8 MAX.3.15 6.9 1mm Pitch 15pin max.1 max.1 max.1 max.1 6.9 No.15 No.1 Center of FCC 13.8 zCharacteristics Parameter Symbol Typ. Unit Effective scanning width − 216 mm Primary scan dot density − 1200 dpi Total dot number − 10368 dots Power supply voltage VDD 3.3 V Reference voltage VREF 0.8 V Scanning speed SLT 1.0 x 3 ms / line CLK 4 MHz Maximum dynamic range VRMax 0.5 V Minimum dynamic range VRMin. 0.25 V Vod VREF + − 0.1 V − 5 to 45 °C Clock frequency Dark output Operating temperature www.rohm.com c 2009 ROHM Co., Ltd. All rights reserved. ○ 1/5 2009.11 - Rev.A LSH1208-BA50A Data Sheet zPin assignments No. Circuit I/O Function 1 AO3 O Analog output 2 GND I Ground 3 AO2 O Analog output 4 GND I Ground 5 AO1 O Analog output 6 MODE I Mode select 7 GND I Ground 8 VDD I Power supply 9 VREF I Reference voltage 10 SP I Start pulse 11 CLK I Clock 12 V-LED I LED power supply 13 B-GND I BLUE LED ground 14 G-GND I GREEN LED ground 15 R-GND I RED LED ground zTiming chart (a) CLK Timing Chart 1/fCLK twH twL CLK 50% 50% SP tSETUP tHOLD ts Ao 1pixel www.rohm.com c 2009 ROHM Co., Ltd. All rights reserved. ○ 2/5 2pixel 2009.11 - Rev.A LSH1208-BA50A Data Sheet (b-1) Data Output Timing Chart (1200dpi mode) After turning on the SP pulse, the analog output starts from the setting up point of 82 clock pulse. 1200dpi mode 1 2 82 CLK SP A O1 to 3 VREF output period A O1 : A O2 : A O3 : 1 to 82clock 1 to 82clock 1 to 82clock Vdummy Analog output period 1 to 100pixels − − 101 to 3456pixels 3457 to 6912pixels 6913 to 10312pixels Vdummy − − 10313 to 10368pixels Note)The CLK section area which is over the effective pixel numbers (Output blank part) cannot be used as the analog Output standard level. (b-2) Data Output Timing Chart (600dpi mode) After turning on the SP pulse, the analog output starts from the setting up point of 82 clock pulse. 600dpi mode 1 2 82 CLK SP A O1 to 3 VREF output period A O1 : A O2 : A O3 : 1 to 82clock 1 to 82clock 1 to 82clock Vdummy Analog output period Vdummy 1 to 50pixels − − 51 to 1728pixels 1729 to 3456pixels 3457 to 5156pixels − − 5157 to 5184pixels Note)The CLK section area which is over the effective pixel numbers (Output blank part) cannot be used as the analog Output standard level. www.rohm.com c 2009 ROHM Co., Ltd. All rights reserved. ○ 3/5 2009.11 - Rev.A LSH1208-BA50A Data Sheet (b-3) Data Output Timing Chart (300dpi mode) After turning on the SP pulse, the analog output starts from the setting up point of 82 clock pulse. 300dpi mode 1 2 82 CLK SP A O1 to 3 VREF output period 1 to 82clock 1 to 82clock 1 to 82clock A O1 : A O2 : A O3 : Vdummy Analog output period Vdummy 1 to 25pixels − − 26 to 864pixels 865 to 1728pixels 1729 to 2578pixels − − 2579 to 2592pixels Note)The CLK section area which is over the effective pixel numbers (Output blank part) cannot be used as the analog Output standard level. zCircuit diagram VDD 1µF×6 GND 1 10368 VDD SP VREF ANALOG MEMORY CIRCUIT CLK MODE 1 3456 3457 6912 6913 10368 AO1 AO2 AO3 MODE VREF VLED RGND GGND BGND www.rohm.com c 2009 ROHM Co., Ltd. All rights reserved. ○ 4/5 2009.11 - Rev.A LSH1208-BA50A Data Sheet zPeripheral circuit SENSOR UNIT 13 14 15 12 1 3 5 9 8 10 11 R3 2, 4, 7 6 GND MODE C5 R3 R1 R2 B G R R3 C1 A 3 C3 A 2 A 1 SP VDD CLK C2 LED GND C4 VREF VLED R1=R2=100Ω, R3=100KΩ C1=C2=47µF C3=100µF, C4=0.1µF, C5=100pF www.rohm.com c 2009 ROHM Co., Ltd. All rights reserved. ○ 5/5 2009.11 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuel-controller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2009 ROHM Co., Ltd. All rights reserved. R0039A