DC - 2 WIRE NAMUR Brass, Nickel Plated (BN), and Plastic

PREVIOUS
DC - 2 WIRE NAMUR
Brass, Nickel Plated (BN),
and Plastic (TROGAMID-T)
Cylindrical,Threaded
HOME
NEXT
• Low energy device
• Operates in hazardous
areas with external
amplifier
• Meets NAMUR regulations
and DIN 19234 specifications
• Carries
FIND IT
• IEC(529) IP67 (NEMA 1, 3, 4, 6, 12, 13) Protection
• Reverse Polarity Protection
• Plastic and Metal Housing according to NAMUR
Regulations and DIN 19234
• Temperature Range: -25 to 70°C (-13 to 158°F)
(For extended temperature models of -40°C to
+125°C, consult Altech.)
mark
M8 Flush Mount
Sensing Distance
Cable or Connector Style Cat. No.
Nickel Plated Brass (BN)
M8 Non-Flush Mount
1mm (.04 in.)
2mm (.08 in.)
Cable
65
Cable
65
9932-0100
9932-0165
9932-0200
9932-0265
Plastic (TROGAMID T)
9932-1600
≤5%
≤5%
≤15%
≤5%
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
Output Current ( with target detection)
0.5 mA
0.5 mA
0.5 mA
0.5 mA
Output Current ( no target detection)
3.5 mA
3.5 mA
3.5 mA
3.5 mA
2000 0Hz
2000 Hz
1000 Hz
1000 Hz
Hysterisis
≤15%
≤15%
≤15%
≤15%
Temperature Drift
≤10%
≤10%
≤10%
≤10%
.1mm (.004 in.)
.1mm (.004 in.)
.2mm (.008 in.)
.2mm (.008 in.)
Ripple Voltage
Switching Frequency
Repeatability
Front Cap Material
PBTP (Metal Housing)
PBTP (Metal Housing)
PBTP (Metal Housing)
M
M
8
8
Fixed Cable
PVC 2m (6ft. 6in.). For 5m (16 ft. 5 in.)
cable length, change the last two
digits of the part number to 02. For
other cable lengths and/or PUR cable,
please consult Altech. Non-metallic
locknuts for M8 and Brass, Nickel Plated
(BN) locknuts for M12 through M30.
PBTP (Metal Housing)
x
x
30
5
1
1
30
25
Voltage Range (supplied by
Pulsotronic 8100-2200 Unit)
M
28
23
5
1
1
x
x
8
8
M
50
12
50
M
x
1
1
x
©Altech
12
50
M
65 Style Connector
4-pin, Micro style, 12mm (.47 in.) supplied
with non-metallic locknuts for M8 and Brass,
Nickel Plated (BN) locknuts for M12 through
M30.
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490
PREVIOUS
HOME
NEXT
Metric/in. Conversion Table
1.0 mm
5.0 mm
6.0 mm
8.0 mm
12.0 mm
23.0mm
=
=
=
=
=
=
.04 in.
.20 in.
.23 in.
.31 in.
.47 in.
.91 in.
24.0 mm
25.0 mm
28.0 mm
30.0 mm
40.0 mm
50.0 mm
FIND IT
Accessories
=
=
=
=
=
=
2 meter (6 ft. 6 in.) DC Cable Assemblies
for Quick Disconnect Sensors
.94 in.
1.0 in.
1.16 in
1.20 in.
1.57 in.
1.97 in.
This table
converts millimeters
to inches in reference
to the illustrations
included on these
pages
65 Connectors, 4 PIN – 4 Wire cable (PIN 1, 2, 3, 4) :
65 Connector 8000-5280
PVC Right Angle
Channge last digit of connector number to 5
for 5 meter cable
Refer to pages 116-121 for more
cable information
M12 Flush Mount
M12 Non-Flush Mount
2mm (.08 in.)
4mm (.16 in.)
Cable
65
Cable
65
9932-0300
9932-0365
9932-0400
9932-0465
9932-1100
9932-1000
≤15%
≤5%
≤5%
≤5%
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
8.2V DC at 1KΩ
0.5 mA
0.5 mA
0.5 mA
0.5 mA
3.5 mA
3.5 mA
3.5 mA
3.5 mA
2000 Hz
2000 Hz
1000 Hz
1000 Hz
≤15%
≤15%
≤15%
≤15%
≤10%
≤10%
≤10%
≤10%
.2mm (.008 in.)
.2mm (.008 in.)
.4mm (.016 in.)
.4mm (.016 in.)
PBTP (Metal Housing)
Remote Amplifier –
Use 8100-2200, see page 123
PBTP (Metal Housing)
PBTP (Metal Housing)
Mounting Brackets – see Pages 114-115
PBTP (Metal Housing)
Note: Sensor dimensions in mm.
Wiring Diagrams
Note: Wire colors are applicable to cable
purchased from Altech
1
1
x
x
12
12
M
M
Fixed Cable
BR
+
24
30
6
Remote
Amplifier
BL
–
M
12
1
12
x
M
65 Connector
x
1
BR
1
+
4
24
Amplifier
3
40
2
12
50
M
3
4 0
50 0
6
Remote
WHT –
x
1
©Altech
Corp. • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490