NEXT FIND IT Table of Contents CLICK FOR PDF FILE CLICK FOR PDF FILE CLICK FOR PDF FILE OVERVIEW – Inductive Proximity Sensors CYLINDRICAL Inductive Proximity Sensors LIMIT STYLE Inductive Proximity Sensors Introduction ........................................4 Operation ............................................5 Introduction/Operation .......................8 Selection Guide, DC styles................12 Selection Guide, AC styles ................14 Product Specifications......................16 Introduction/Operation .....................68 Selection Guide.................................71 Product Specifications......................72 CLICK FOR PDF FILE CLICK FOR PDF FILE CLICK FOR PDF FILE BLOCK STYLE Inductive Proximity Sensors RING STYLE Inductive Proximity Sensors ACCESSORIES for Inductive Proximity Sensors Introduction/Operation .....................80 Selection Guide.................................82 Product Specifications......................84 Introduction/Operation .....................98 Selection Guide...............................100 Product Specifications....................102 Introduction ....................................113 Mounting Brackets .........................114 Cable Assemblies............................116 Switching Units...............................122 Motion Detectors............................128 OTHER INFORMATION APPENDIX: IP Codes .........................................132 NEMA requirements .......................133 Cross Reference .............................134 Glossary..........................................135 Conversion Charts ..........................137 INDEX .............................................138 TERMS & CONDITIONS .................141 WARRANTY....................................143 All specifications subject to change without notice or obligation Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490 3 APPENDIX PREVIOUS HOME NEXT FIND IT IP Codes (International Protection) Protection Levels - IEC 529/ EN 60529, DIN, VDE 0470 Part 1 IEC 529 outlines an international classification system for the sealing effectiveness of enclosures of electrical equipment against the intrusion into the equipment of foreign bodies (i.e., tools, dust, fingers) and moisture. This classification system utilizes the letter "IP" (International or Ingress Protection) followed by two digits. (An "X" is used for one of the digits if there is only one class of protection; i.e., IP X4 which addresses moisture resistance only.) 1st digit 0 1 2 First Digit Degree of protection against contact with moving parts (other than smooth rotating shafts, etc.) and the ingress of solid foreign bodies. Second Digit Degree of protection against the harmful entry of various forms of moisture (i.e., dripping, spraying, submersion, etc. 3 Protection From Solid Objects No special protection Protection from a large part of the body such as a hand (but no protection from deliberate access); from solid objects greater than 50mm in diameter. Protection against fingers or other objects not greater than 80mm in length and 12mm in diameter. Protection from entry by tools, wires, etc., with a diameter or thickness greater that 2.5mm 4 Protection from entry by solid objects with a diameter or thickness greater than 1.0mm 5 Protection from the amount of dust that would interfere with the operation of equipment 6 Dust-tight 2st digit Protection From Moisture 0 1 2 No special protection Protection from dripping water Protection from vertically dripping water 3 Protection from sprayed water 4 Protection from splashed water 5 Protection from water projected from a nozzle 6 Protection against heavy seas, or powerful jets of water 7 Protection against immersion 8 Protection against complete continuous submersion in water Note: All first digits and second digits up to and including characteristic digit 6, imply compliance also with the requirements for all lower characteristic digits in their respective series (first or second). Second digits 7 and 8 do not imply suitability for exposure to water jets (second characteristic digit 5 or 6) unless dual coded; i.e., IP _5/IP_7. 132 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490 PREVIOUS NEMA Enclosure Standards The following information is derived from the NEMA Standard #250, dated May 1988. Altech is providing this information as a guideline. Please consult the NEMA Standards for your specific requirements. HOME NEXT FIND IT NEMA REFERENCE NON-HAZARDOUS LOCATIONS TESTS CONDUCTED TYPE 1 enclosures are intended for indoor use primarily to provide a degree of protection against contact with the enclosed equipment. Rust entry Rust resistance TYPE 2 enclosures are intended for indoor use primarily to provide a degree of protection against limited amounts of falling water and dirt. Rod entry Drip Rust resistance TYPE 3 enclosures are intended for outdoor use primarily to provide a degree of protection against windblown dust, rain, and sleet; and to be undamaged by the formation of ice on the enclosure. Rain Dust External icing Rust resistance TYPE 3R enclosures are intended for outdoor use primarily to provide a degree of protection against falling rain; and to be undamaged by the formation of ice on the enclosure. Rod entry Rain External icing Rust resistance TYPE 3S enclosures are intended for outdoor use primarily to provide a degree of protection against windblown dust, rain, and sleet, and to provide for operation of external mechanisms when ice laden. Rain Dust External icing Rust resistance TYPE 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water, and hose directed water. Hosedown External icing Rust resistance TYPE 4X enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water, and hose -directed water. Hosedown External icing Corrosion resistance TYPE 6 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against the entry of water during temporary submersion at a limited depth. Submersion External icing Rust resistance TYPE 6P enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against the entry of water during prolonged submersion at a limited depth. Air pressure External icing Corrosion resistance TYPE 12 enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids. Drip Dust Rust resistance TYPE 13 enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying water, oil, and non-corrosive coolant. Oil exclusion Rust resistance HAZARDOUS LOCATIONS TESTS CONDUCTED TYPE 7 enclosures are intended for indoor use in locations classified as Class I, Groups A, B, C, or D, as defined in the National Electrical Code. Explosion Hydrostatic Temperature TYPE 9 enclosures are intended for indoor use in locations classified as Class II, Groups E, F or G, as defined in the National Electrical Code. Dust Penetration Temperature Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490 133 PREVIOUS HOME NEXT FIND IT Conversion Chart from L, R, & T Series Sensors to 8 digit Altech part numbers The chart below is provided to aid our customers who wish to order Altech/Pulsotronic Sensors that have previously been ordered by part numbers beginning with L', 'R' or 'T'. If you have a part with the 'L', 'R' or 'T' designation listed Model Specifications same as below, the equivalent Altech/Pulsotronic part number is listed for your convenience. Customer service will accept orders with either number. Model Specifications same as Model Specifications same as Model Specifications same as L12-A113 9853-2400 T12-A160 9952-0400 T18-A1180 9954-2267 T30-A118 9956-1566 L12-D313 9863-2100 T12-A161 9952-0462 T18-A160 9954-1900 T30-A1180 9956-1567 L12-D413 9863-0400 T12-A1610 9952-0468 T18-A161 9954-1962 T30-A160 9956-1400 R40-A605 9853-3031 T12-A168 9952-0466 T18-A1610 9954-1968 T30-A161 9956-1462 R40-A655 9853-3131 T12-A1680 9952-0467 T18-A168 9954-1966 T30-A1610 9956-1468 R40-A-675 9853-3231 T12-A210 9952-0900 T18-A1680 9954-1967 T30-A168 9956-1466 R40-D305 9863-3333 T12-A211 9952-0962 T18-A210 9954-2600 T30-A1680 9956-1467 R40-D355 9863-3433 T12-A2110 9952-0968 T18-A211 9954-2662 T30-A210 9956-1900 R40-D375 9863-3533 T12-A218 9952-0966 T18-A2110 9954-2668 T30-A211 9956-1962 R40-D405 9863-3033 T12-A2180 9952-0967 T18-A218 9954-2666 T30-A2110 9956-1968 R40-D455 9863-3133 T12-A260 9952-0800 T18-A2180 9954-2667 T30-A218 9956-1966 R40-D475 9863-3233 T12-A261 9952-0862 T18-A260 9954-2500 T30-A2180 9956-1967 T04-D410 9961-1000 T12-A2610 9952-0868 T18-A261 9954-2562 T30-A260 9956-1800 T05-D410 9961-1100 T12-A268 9952-0866 T18-A2610 9954-2568 T30-A261 9956-1862 T08-D310 9907-1900 T12-A2680 9952-0867 T18-A268 9954-2566 T30-A2610 9956-1868 T08-D310L 9961-0300 T12-D310 9962-1500 T18-A2680 9954-2567 T30-A268 9956-1866 T08-D318 9961-0365 T12-D311 9962-4162 T18-D310 9964-1600 T30-A2680 9956-1867 T08-D3180 9961-0363 T12-D318 9962-4165 T18-D311 9964-4162 T30-D310 9966-1200 T08-D360 9907-2100 T12-D3180 9962-4163 T18-D318 9964-4165 T30-D311 9966-4162 T08-D360L 9961-0500 T12-D360 9962-1700 T18-D3180 9964-4163 T30-D318 9966-4165 T08-D368 9961-0565 T12-D361 9962-4362 T18-D360 9964-1800 T30-D3180 9966-4163 T08-D3680 9961-0563 T12-D368 9962-4385 T18-D361 9964-4362 T30-D360 9966-1400 T08-D410 9907-1800 T12-D3680 9962-4363 T18-D368 9964-4365 T30-D361 9966-4362 T08-D410L 9961-0200 T12-D410 9962-1400 T18-D3680 9964-4363 T30-D368 9966-4365 T08-D418 9961-0265 T12-D411 9962-4062 T18-D410 9964-1500 T30-D3680 9966-4363 T08-D4180 9961-0263 T12-D418 9962-4065 T18-D411 9964-4062 T30-D410 9966-1100 T08-D460 9907-2000 T12-D4180 9962-4063 T18-D418 9964-4065 T30-D411 9966-4062 T08-D460L 9961-0400 T12-D460 9962-1600 T18-D4180 9964-4063 T30-D418 9966-4065 T08-D468 9961-0465 T12-D461 9962-4262 T18-D460 9964-1700 T30-D4180 9966-4063 T08-D4680 9961-0463 T12-D468 9962-4265 T18-D461 9964-4262 T30-D460 9966-1300 T12-A110 9952-0500 T12-D4680 9962-4263 T18-D468 9964-4265 T30-D461 9966-4262 T12-A111 9952-0562 T18-A110 9954-2200 T18-D4680 9964-4263 T30-D468 9966-4265 T12-A1110 9952-0568 T18-A111 9954-2262 T30-A110 9956-1500 T30-D4680 9966-4263 T12-A118 9952-0566 T18-A1110 9954-2268 T30-A111 9956-1562 9803-30 9803-3800 T12-A1180 9952-0567 T18-A118 9954-2266 T30-A1110 9956-1568 9803-38 9803-3862 134 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490 PREVIOUS HOME Glossary of Technical Definitions and Terminology Active Surface: Portion of the sensor from which the electromagnetic field radiates. Analog Output: The output voltage is proportionately to the distance of the target to the sensor's active surface. Complementary Outputs (N.O. & N.C.): A proximity sensor that features both normally open and a normally closed output, which can be used simultaneously. Correction Factors: Multiplication factors taking into account variations in the target material composition. When calculating actual sensing distance, this figure should be multiplied by the normal sensing distance, Sn. Current Sinking: See NPN Current Sourcing: See PNP Damping Material: Material which causes a decrease in the strength of the electromagnetic or electrical field produced by the sensing coil. Differential Travel: See Hysteresis. Dynamic Output: A sensor output that outputs a short pulse of a defined period when a target is detected. Effective Operating Distance - 'Sr': The operating distance of an individual proximity switch measured at stated temperature and voltage. It takes into account variations in manufacturing tolerances. Ferrous Metal: Any metal containing iron. Flush Mounting: A shielded or embedded proximity sensor can be flush mounted in metal. It can be surrounded by metal up to the active sensing face. Hysteresis: The difference, in percentage (%),of the nominal sensing distance between the operate (switch on) and release point (switch off) when the target is moving away from the sensor's active face. Without sufficient hysteresis a proximity sensor will "chatter" (continuously switch on and off) when there is a significant vibration applied to the target or sensor. Leakage Current: Current which flows through the output when the output is in an "off" condition or de-energized. NEXT FIND IT LED: Light Emitting Diode used to indicate sensor status. Load: A device that consumes power to perform a function. Maximum Load Current: The maximum current at which the proximity sensor can be continuously operated. Minimum Inrush Current: The maximum current level at which the proximity sensor can be operated for a short period of time. Minimum Load Current: The minimum amount of current required by the sensor to maintain reliable operation. Namur Sensor: A 2-wire, variable resistance sensor which requires a remote amplifier for operation. Typically used in intrinsically safe applications. Nominal Sensing Distance: The distance,Sn, at which an approaching target activates (changes state of) the proximity output. This is also called the rated operating distance. Non-Ferrous Metal: Any metal which does not contain iron. Non-Flush Mounting: Unshielded, or non-embeddable sensors must have a so called "free zone" around the sensor head, with no non-target metal present to operate satisfactorily. Normally Closed: Output opens when an object is detected in the active switching area. Normally Open: Output closes when an object is detected in the active switching area. NPN: The sensor switches the load to the positive terminal. The load should be connected between the sensor output and positive terminal. Operating Distance, Assured: Between 0 and 81% of the rated operating distance for inductive proximity switches. It is specified as Sa. Operating Distance, Rated: The operating distance specified by the manufacturer and used as a reference value. Also known as nominal sensing distance, Sn. Overload Protected: The ability of a sensor to withstand load currents between continuous load rating and a short circuit condition without any damage. continued... Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490 135 PREVIOUS HOME NEXT FIND IT Glossary, cont. PNP: The sensor switches the load to the negative terminal. The load should be connected between the sensor output and negative terminal. Programmable Output, (N.O. or N.C.): Output which can be changed from N.O. to N.C. or N.C. to N.O. by way of a switch or jumper wire. Also known as selectable output. Rated Operating Distance - 'Sn': Sometimes called nominal operating distance, it does not take into account manufacturing tolerances or variations in temperature or voltage. Repeatability: The repeat accuracy of a sensor to detect an object at the same distance away from the active sensing face. It is expressed as a percentage of the sensing distance, or can be calculated as a specific measurement value. Residual Voltage: The voltage across the sensor output while energized and switching the maximum load. It is the voltage drop across the sensor. Response Time: See Switching Frequency Reverse Polarity Protection: Proximity sensors which are protected against a reversal in voltage polarity. Ripple: The variance between peak-to-peak values in DC voltage. It is expressed as a percentage of rated voltage. Sensing Face: A surface of the proximity sensor parallel to the target, from which the operating distance is measured Shielded: Sometimes called Flush or Embedded. Short Circuit Protection: Sensor protected from damage when a shorted condition exists for an indefinite period of time without change. Static Output: A sensor output that stays energized as long as the target is present. Supply Current: The current consumed by the proximity switch when the output transistor is in the off condition. Switching Frequency: The maximum number of times per second the sensor can change state, (ON and OFF), usually expressed in Hertz (Hz)., as measured by DIN EN 50010. Target: Object which activates the sensor. 136 Temperature Drift: Specification used to indicate the change in switching point caused by temperature variations within a specified ambient temperature range. Expressed as a percentage of the sensing distance. Useable Operating Distance - 'Su': The operating distance measured over a voltage range of 85% to 110% of its rated voltage. It allows for manufacturing tolerances. Voltage Drop: The maximum voltage drop across a conducting sensor. Weld Field Immunity (WFI): The ability of a sensor not to false trigger in the presence of strong electromagnetic fields. Wire Break Protection: The output is off if either power supply wire is broken. SENSOR HOUSING MATERIALS Plastics: Trogamid T – Polyamide, used in cylindrical, block and limit style sensors. Hard, rigid, good resistance to chemicals, resists caustic cleaners, approved for food contact. PBTP: Polybutelyne terephthalate, used in block sensors and front caps of cylindrical nickel plated brass units. Excellent mechanical strength and temperature resistance. Self-extinguishing and flame retardant. Weld splash proof. PA6.6: Polyamid (Nylon), used in limit style sensors. Excellent mechanical strength, temperature resistant, accepted in food industry. ABS: Acrylonitrile-Butadiene-Stypol. Used in ring sensors. Impact resistant. Rigid. PUR: Polyurethane, used in cables and cable assemblies. Elastic, abrasion proof, impact resistant, unaffected by oil, grease and solvents. PVC: Polyvinylchloride, used on cables and cable assemblies. Good mechanical strength, resistant to chemicals. PTFE – TEFLON: Used on weld immune cylindrical sensors. Highest resistance to high temperature and chemicals. METALS: Brass, Nickel Plated, used on cylindrical sensors. Rugged, resists thread damage. Aluminum, used on block and ring sensors. Lightweight, excellent strength to weight ratio. Resistant to corrosion. Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490 PREVIOUS HOME NEXT FIND IT Commonly used metric and other useful conversions Length inch [in.] millimeters [mm] meters [m] miles [mi] kilometers [km] x25.4 x0.03937 x3.281 x1.609 x0.6214 =millimeters =inches =feet =kilometers =miles Torque Newtonmeter [Nm] lb-ft lb-in oz-in x0.738 x1.356 x0.113 x0.0071 =lb-ft =Nm =Nm =Nm Power kilowatt [kW] hp x1.341 x0.7457 =hp =kW Moment of Inertia (WR2) x0.042 lb-ft2 kilogrammeter2 23.720 [kgm2 ] Weight Mass and Force Newton [N] x0.02248 kilogram [kg] x2.205 pound [lb] x4.448 pound [lb] x0.4536 =kgm2 =lb-ft2 =pounds =pounds =N =kg DEGREES CELCIUS VERSUS DEGREES FAHRENHEIT °C °F °C °F -80 -70 -60 -50 -45 -112.0 -94.0 -65.0 -58 -49.1 -20 -19 -18 -17 -16 -4.0 -2.2 -0.4 +1.4 3.2 -40 -39 -38 -37 -36 -40.0 -38.2 -36.4 -34.6 32.8 -15 -14 -13 -12 -11 -35 -34 -33 -32 -31 -31.0 29.2 -27.4 -25.6 -23.8 -30 -29 -28 -27 -26 -25 -24 -23 -22 -21 °C °F °C °F 5 6 7 8 9 41.0 42.8 44.6 46.4 48.2 30 31 32 33 34 86.0 87.8 89.6 91.4 93.2 5.0 6.8 8.6 10.4 12.2 10 11 12 13 14 50.0 51.8 53.6 55.4 57.2 35 36 37 38 39 -10 -9 -8 -7 -6 14.0 15.8 17.6 19.4 21.2 15 16 17 18 19 59.0 60.8 62.6 64.4 66.2 -22.0 -22.0 -18.4 -16.6 -14.8 -5 -4 -3 -2 -1 23.0 24.8 26.6 28.4 30.2 20 21 22 23 24 -13.0 -11.2 -9.4 -7.6 -5.8 0 1 2 3 4 32.0 33.8 35.6 37.4 39.2 25 26 27 28 29 Conversion Formula °F = 9/5°C + 32° °C °F °C °F °C 55 56 57 58 59 131.0 132.8 134.6 136.4 138.2 80 81 82 83 84 176.0 177.8 179.6 181.4 183.2 105 106 107 108 109 95.0 96.8 98.6 100.4 102.2 60 61 62 63 64 140.0 141.8 143.6 145.4 147.2 85 86 87 88 89 185.0 186.8 188.6 189.4 192.2 40 41 42 43 44 104.0 105.8 107.6 109.4 111.2 65 66 67 68 69 149.0 150.8 152.6 154.4 156.2 90 91 92 93 94 68.0 69.8 71.6 73.4 75.2 45 46 47 48 49 113.0 114.8 116.8 118.4 120.2 70 71 72 73 74 158.0 159.8 161.6 163.4 165.2 77.0 78.8 80.6 82.4 84.2 50 51 52 53 54 122.0 123.8 125.6 127.4 129.2 75 76 77 78 79 167.0 168.8 170.6 172.4 174.2 °F °C °F °C °F 221.0 222.8 224.6 226.4 228.2 130 131 132 133 134 266.0 267.8 269.6 271.4 273.2 200 210 220 230 240 392 410 428 446 464 110 111 112 113 114 230.0 231.8 233.6 235.4 237.2 135 136 137 138 139 275.0 276.8 278.6 280.4 282.2 250 300 350 400 500 482 572 662 752 932 194.0 195.8 197.6 199.4 201.2 115 116 117 118 119 239.0 240.8 242.6 244.4 246.2 140 141 142 143 144 284.0 285.8 287.6 289.4 291.2 600 700 800 900 1000 1112 1292 1472 1652 1832 95 96 97 98 99 203.0 204.8 206.6 208.4 210.2 120 121 122 123 124 248.0 249.8 251.6 253.4 255.2 145 146 147 148 149 293.0 294.8 296.6 298.4 300.2 1100 1200 1300 1400 1500 2012 2192 2372 2552 2732 100 101 102 103 104 212.0 213.8 215.6 217.4 219.2 125 126 127 128 129 257.0 258.8 260.6 262.4 264.2 150 160 170 180 190 302.0 320.0 338.0 356.0 374.0 1600 1700 1800 1900 2000 2912 3092 3272 3452 3632 °C = 5/9(°F-32°) Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490 137 INDEX PREVIOUS HOME NEXT FIND IT Index by Catalog Number Cat. # 138 Page 8000-5030 8000-5040 8000-5060 8000-5070 8000-5110 8000-5120 8000-5130 8000-5140 8000-5150 8000-5160 8000-5220 8000-5230 8000-5240 8000-5280 116 116 116 116 118 118 119 119 120 120 121 121 121 118 8100-0930 8100-2100 8100-2130 8100-2200 8100-2400 8100-2500 8100-2700 8100-2800 8102-0900 124 125 125 125 126 126 130 130 124 8300-0100 8300-0500 8303-0430 8309-0130 8309-0230 122 122 129 127 127 9512-6100 9512-6200 9512-6400 9512-6600 9512-8200 114 114 114 114 115 9700-0159 9701-0259 9701-0759 9702-0259 9702-0400 9702-0500 9703-0159 9704-0159 9705-0259 9705-0500 9705-0659 9706-0159 9706-0659 9707-0159 9707-0659 9787-0059 9708-0059 9708-0159 9708-0559 9708-0659 108 106 106 106 102 102 109 109 104 102 104 105 105 105 105 104 104 104 104 104 Cat. # Page Cat. # Page 9709-0259 9709-0359 9711-0059 9713-0059 9714-2000 9714-4300 9803-3000 9807-0100 9807-0159 9807-0165 9807-0900 9807-0959 9807-0965 9809-0100 9809-0159 9809-0300 9809-0359 9809-0400 9809-0459 9809-0500 9809-0559 9809-3400 9809-3459 9809-3500 9809-3559 9814-1133 9814-2133 9853-2400 9853-2500 9853-3600 9853-3700 9853-3800 9853-3900 9853-5831 9853-5931 9855-0062 9855-1000 9855-1100 110 110 108 106 112 112 95 88 88 88 88 88 88 90 90 90 90 90 90 90 90 90 90 90 90 75 92 94 94 94/96 94/96 94/96 94/94 78 78 95 95 95 9863-5933 9864-0200 9865-1033 9865-1133 9873-0031 9873-0231 9873-3031 9873-3231 76 88 91 91 74 74 77 77 9883-2033 9883-2233 9883-2333 9883-2533 9883-3033 9883-3233 9883-3333 9883-3533 72 72 72 72 73 73 73 73 9914-0500 9914-0565 9914-0800 9914-0865 9914-0900 9914-0965 9914-1000 9916-2100 9916-2168 9916-2300 9916-2368 9916-2400 9916-2500 9916-2600 9916-2668 9916-2700 9916-2768 9916-2900 9916-3000 44 44 44 44 44 44 44 62 62 63 63 62 63 62 62 63 63 62 63 9861-1000 9861-1064 9861-1100 9861-1164 9863-0400 9863-0464 9863-2100 9863-2164 9863-2700 9863-2764 9863-2900 9863-2964 9863-3800 9863-3900 9863-4300 9863-4400 9863-4600 9863-5833 84 84 84 84 86 87 87 86 86 86 86 86 93 93 128 128 128 76 9921-1200 9921-1268 9921-1300 9921-1368 9921-1369 9921-1500 9921-1568 9921-1700 9921-1768 9921-2000 9921-2100 9921-2200 9921-2300 9924-0400 9924-0468 9924-0500 9924-0568 9921-0700 9924-0768 61 61 61 61 61 61 61 61 61 61 61 61 61 60 60 60 60 60 60 Cat. # Page 9924-0900 9924-0968 9924-1000 9924-1100 9924-1200 9924-1300 60 9932-0100 9932-0165 9932-0200 9932-0265 9932-0300 9932-0365 9932-0400 9932-0465 9932-0500 9932-0565 9932-0600 9932-0665 9932-0700 9932-0765 9932-0800 9932-0865 9932-1000 9932-1100 9932-1300 9932-1400 9932-1500 9932-1600 50 50 50 50 51 51 51 51 52 52 52 52 53 53 53 53 51 51 52 53 53 50 9952-0400 9952-0462 9952-0466 9952-0467 9952-0468 9952-0500 9952-0562 9952-0566 9952-0567 9952-0568 9952-0800 9952-0866 9952-0867 9952-0868 9952-0900 9952-0966 9952-0967 9952-0968 9952-5640 9952-5648 9952-5700 9952-5768 9952-5840 9952-5848 9952-5900 9952-5968 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 56 64 64 64 64 64 64 64 64 60 60 60 60 Cat. # Page 9954-1900 9954-1962 9954-1966 9954-1967 9954-1968 9954-2200 9954-2262 9954-2266 9954-2267 9954-2268 9954-2500 9954-2568 9954-2600 9954-2666 9954-2667 9954-2668 9954-5640 9954-5700 9954-5768 9954-5840 9954-5848 9954-5900 9954-5968 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 57 65 65 65 65 65 65 65 9956-1400 9956-1462 9956-1466 9956-1467 9956-1468 9956-1500 9956-1562 9956-1566 9956-1568 9956-1800 9956-1868 9956-1900 9956-5640 9956-5648 9956-5700 9956-5768 9956-5840 9956-5848 9956-5900 9956-5968 59 59 59 59 59 58 58 58 58 59 59 58 66 66 66 66 66 66 66 66 9961-0200 9961-0263 9961-0264 9961-0265 9961-0300 9961-0363 9961-0364 9961-0365 9961-0400 9961-0463 9961-0464 9961-0465 24 24 24 24 24 24 24 24 24 24 24 24 Cat. # Page 9961-0500 9961-0563 9961-0564 9961-0565 9961-1200 9961-1264 9961-1300 9961-1364 9961-4400 9961-4464 9961-4465 9961-4500 9961-4564 9961-4565 9961-4600 9961-4664 9961-4665 9961-4700 9961-4764 9961-4765 24 24 24 24 35 35 35 35 24 24 24 24 24 24 24 24 24 24 24 24 9962-1400 9962-1500 9962-1600 9962-1700 9962-2300 9962-2365 9962-3100 9962-3200 9962-3300 9962-3400 9962-4000 9962-4063 9962-4064 9962-4065 9962-4100 9962-4163 9962-4164 9962-4165 9962-4200 9962-4263 9962-4264 9962-4265 9962-4300 9962-4363 9962-4364 9962-4365 9962-4400 9962-4464 9962-4465 9962-4500 9962-4564 9962-4565 9962-4600 9962-4664 9962-4665 9962-4700 32 32 32 32 31 31 32 32 32 32 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 25 24 24 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490 PREVIOUS HOME NEXT FIND IT Index by Catalog Number Cat. # Page 9962-4764 9962-4765 9962-5600 9962-5665 9962-5700 9962-5764 9962-5765 9962-5840 9962-5845 9962-5900 9962-5965 9962-6010 9962-6065 9962-6110 9962-6165 9962-6200 9962-6265 9962-6300 9962-6365 24 24 54 54 54 54 54 40 40 40 40 38 38 38 38 36 36 36 36 9964-1500 9964-1600 9964-1700 9964-1800 9964-3100 9964-3200 9964-3300 9964-3400 9964-4000 9964-4063 9964-4065 9964-4100 9964-4163 9964-4165 9964-4200 9964-4263 9964-4265 9964-4300 9964-4363 9964-4365 9964-4400 9964-4465 9964-4500 9964-4565 9964-4600 9964-4665 9964-4700 9964-4765 9964-5400 9964-5500 9964-5840 9964-5845 9964-5900 9964-5965 9964-6010 9964-6065 9964-6110 32 32 33 33 32 32 33 33 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26 54 54 41 41 41 41 39 39 39 Cat. # Page 9964-6165 9964-6200 9964-6265 9964-6300 9964-6365 39 37 37 36 36 9966-1100 9966-1200 9966-1300 9966-1400 9966-3300 9966-3400 9966-3900 9966-3965 9966-4000 9966-4063 9966-4065 9966-4100 9966-4163 9966-4165 9966-4200 9966-4263 9966-4265 9966-4300 9966-4365 9966-4400 9966-4465 9966-4500 9966-4565 9966-4600 9966-4665 9966-4700 9966-4765 9966-5400 9966-5500 9966-5840 9966-5845 9966-5900 9966-5965 33 33 33 33 33 33 30 30 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 55 55 42 42 42 42 9980-1010 9980-1064 9980-1110 9980-1164 9980-2010 9980-2064 9980-2110 9980-2164 34 34 34 34 34 34 34 34 9981-2000 9981-2064 9981-2065 9981-2100 9981-2164 9981-2165 9981-2200 9981-2264 16 16 16 16 16 16 16 16 Cat. # Page 9981-2265 9981-2300 9981-2364 9981-2365 9981-4000 9981-4064 9981-4065 9981-4100 9981-4164 9981-4165 9981-4200 9981-4264 9981-4265 9981-4300 9981-4364 9981-4365 9981-5000 9981-5064 9981-5065 9981-5200 9981-5264 9981-5265 16 16 16 16 28 28 28 28 28 28 28 28 28 28 28 28 46 46 46 46 46 46 9982-2000 9982-2064 9982-2065 9982-2100 9982-2164 9982-2165 9982-2200 9982-2264 9982-2265 9982-2300 9982-2364 9982-2365 9982-4000 9982-4064 9982-4065 9982-4100 9982-4164 9982-4165 9982-4200 9982-4264 9982-4265 9982-4300 9982-4364 9982-4365 9982-4400 9982-4464 9982-4465 9982-4500 9982-4564 9982-4565 9982-4600 9982-4664 9982-4665 9982-4700 17 17 17 17 17 17 17 17 17 17 17 17 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 Cat. # Page 9982-4764 9982-4765 9982-4900 9982-4950 9982-5000 9982-5065 9982-5200 9982-5265 20 20 29 29 47 47 47 47 9984-2000 9984-2065 9984-2100 9984-2165 9984-2200 9984-2265 9984-2300 9984-2365 9984-4000 9984-4065 9984-4100 9984-4165 9984-4200 9984-4265 9984-4300 9984-4365 9984-4400 9984-4465 9984-4500 9984-4565 9984-4600 9984-4665 9984-4700 9984-4765 9984-4900 9984-4950 9984-5000 9984-5065 9984-5200 9984-5265 18 18 18 18 18 18 18 18 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 21 29 29 48 48 48 48 9986-2000 9986-2065 9986-2100 9986-2165 9986-2200 9986-2265 9986-2300 9986-2365 9986-4000 9986-4065 9986-4100 9986-4165 9986-4200 9986-4265 9986-4300 9986-4365 9986-4400 19 19 19 19 19 19 19 19 22 22 22 22 22 22 22 22 22 Cat. # 9986-4465 9986-4500 9986-4565 9986-4600 9986-4665 9986-4700 9986-4765 9986-5000 9986-5065 9986-5200 9986-5265 Page Cat. # Page 22 22 22 22 22 22 22 49 49 49 49 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908) 806-9400 • Fax (908) 806-9490 139 PREVIOUS HOME NEXT FIND IT FAXBACK Thank You We hope this catalog has helped you in your selection of Altech products. To learn more, please complete this form and fax it to us. If you prefer to mail it, fold and seal with clear tape, we've provided the postage. Name Title Company Div./MS Address City State Phone ( ) Zip Fax ( ) ❑ Please contact me to discuss my application. Our product(s) are exported. My company is best classified as a(n): ❑ OEM ❑ Systems Integrator ❑ End User/MRO ❑ Distributor ❑ Contractor ❑ Government/School ❑ ❑ In my job, I: ❑ Specify ❑ Recommend ❑ Authorize ❑ Purchase ❑ Other My primary job function is: ❑ Product Design ❑ Sales/Marketing ❑ System Design ❑ Purchasing ❑ Plant Operations/ ❑ Other _________________ Maintenance ❑ Yes ❑ No Consultant Other Which best describes the end-product produced by your firm? ❑ Controls & Instrumentation ❑ Electronic Systems & Components ❑ Transportation Equipment ❑ Electrical Machinery & Equipment ❑ Specialty Machinery & Equipment ❑ Other Which industry(ies) does your company serve? (Please check all applicable) ❑ Aerospace ❑ Automatic Vending ❑ Agricultural ❑ Automotive ❑ Chemical Processing ❑ Commercial Industrial & HVAC ❑ Construction ❑ Dairy ❑ Defense/Military ❑ Food Processing ❑ Industrial Process Furnaces & Ovens ❑ Machine Tool ❑ Material Handling ❑ Medical & Dental ❑ Metalworking ❑ Mining ❑ Oil & Gas Field ❑ Packaging ❑ Petrochemical Please rush literature on products circled below: CIRCUIT BREAKERS TERMINAL BLOCKS ❑ Miniature DIN ❑ DIN Rail ❑ Motor Controllers ❑ Mini DIN Rail ❑ Earth Leakage ❑ Panel ❑ Accessories ❑ Eurostrips® ❑ Power Busbar ❑ Ceramic ❑ ❑ ❑ Busbar System PCB - Fixed PCB - Pluggable INTERFACES ❑ Interface Modules ENCLOSURES ❑ Industrial ❑ Electronic ❑ DIN ❑ Strain Reliefs ❑ Pharmaceutical Processing ❑ Power Distribution Producing ❑ Primary Metals ❑ Printing & Textiles SENSORS ❑ Proximity Sensors In ❑ ❑ ❑ ❑ Addition: Inductive Proximity Capacitive Proximity Photoelectric Proximity Ultrasonic Proximity ❑ Pulp & Paper ❑ Specialty Chemicals ❑ Textiles OTHER ❑ Foot Switches ❑ Disconnect Switches ❑ European Fuses ❑ Safety Relays ❑ Safety Modules ❑ Timers ❑ Monitoring and Sensing Devices Altech Corp.® • 35 Royal Road • Flemington NJ 08822-6000 • Phone (908) 806-9400 • FAX (908) 806-9490