RS35 and RS50

RS35 and RS50
Relays for Photovoltaic Systems
• Relays to control power in photovoltaic systems which generate electric energy
• Max. switching current: 35 A (version RS35); 50 A (version RS50)
• 5000 V / 10 mm reinforced insulation
• Contact gap > 1.75 mm • Holding power 0.1 W
• For PCB
• DC coils
RS35
RS50
DPST (2 NO)
AgSnO2
250 V / 440 V
10 V
35 A / 250 V AC
35 A / 24 V DC
10 mA
35 A
8750 VA
90 W 0.3 A / 300 V
1W
≤ 50 mΩ
DPST (2 NO)
AgSnO2
250 V / 440 V
10 V
48 A / 250 V AC
48 A / 24 V DC
10 mA
50 A
12500 VA
90 W 0.3 A / 300 V
1W
≤ 50 mΩ
360 cycles/hour
3600 cycles/hour
360 cycles/hour
3600 cycles/hour
5 ... 110 V
DC: ≥ 0.05 Un
0.75...2.0 Un; see page 103
0.48 W
0.3 W
1.9 W 20 °C
5 ... 110 V
DC: ≥ 0.05 Un
0.75...2.0 Un; see page 103
0.48 W
0.3 W
1.9 W 20 °C
250 V AC
6000 V 1.2 / 50 µs
III
3
1000 MΩ
250 V AC
6000 V 1.2 / 50 µs
III
3
1000 MΩ
5000 V AC type of insulation: reinforced
2500 V AC type of clearance: full-disconnection
2500 V AC type of insulation: basic
5000 V AC type of insulation: reinforced
2500 V AC type of clearance: full-disconnection
2500 V AC type of insulation: basic
≥ 10 mm
≥ 10 mm
≥ 10 mm
≥ 10 mm
40 ms / 5 ms
40 ms / 5 ms
3 x 104; 35 A. 250 V AC. 20 °C
3 x 104; 35 A. 250 V AC. 20 °C
106
40 x 25 x 49.2 mm
105 g
104; 50 A. 250 V AC. 20 °C
3 x 104; 50 A. 250 V AC. 20 °C
106
40 x 25 x 49.2 mm
105 g
-40...+105 °C
-40...+85 °C
IP 40 PN-EN 60529
RTI PN-EN 116000-3
10 g
1.5 mm DA (constant amplitude) 0...55 Hz
max. 270 °C
max. 5 s
-40...+105 °C
-40...+85 °C
IP 40 PN-EN 60529
RTI PN-EN 116000-3
10 g
1.5 mm DA (constant amplitude) 10...55 Hz
max. 270 °C
max. 5 s
Contact Data
Number and type of contacts
Contact material
Rated / max. switching voltage
Min. switching voltage
Rated load
Min. switching current
Rated current
Max. breaking capacity
Min. breaking capacity
Contact resistance
Max. operating frequency
• at rated load
• no load
AC
AC1
DC1
AC1
DC1
AC1
Coil Data
Rated voltage
DC
Must release voltage
Operating range of supply voltage
Rated power consumption
DC
Power consumption at pickup voltage
Max. continuous dissipation
Insulation
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Insulation resistance
Dielectric strength
• between coil and contacts
• contact clearance
• pole - pole
Contact - coil distance
• clearance
• creepage
General data
Operating / release time (typical values)
Electrical life
• resistive AC1
• AC7a
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storange
• operating
Cover protection category
Environmental protection
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
102
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
DATA SUBJECT TO CHANGE WITHOUT NOTICE
RS35 and RS50
Relays for Photovoltaic Systems
CONNECTION DIAGRAM
DIMENSIONS
PINOUT
40
DPST (2NO)
25
1
2
2
4 × (7×2.5)
3.5
8.2
2 × (2.8×0.8)
DPST (2NO)
3.5
14.7
4
22.8
22.8
2 × (3.3×1.3)
2.5 × 2.5
4 × (6.5×2)
3
14.7
6
4.5
5
49.2
10
10
RS35 DPST(2NO) DC coil. 35A
Part Number
RS35-3022-25-1012
RS35-3022-25-1024
RS35-3022-25-1110
Coil Voltage
V DC
Coil resistance
at 20 °C in Ω
12
24
110
300
1200
25000
Coil operating range
min. (at 20°C)
max. (at 55°C)
9.00
18.00
82.50
24
48
220
Coil data
Cover protection
IP40
DC
DC
DC
x
x
x
Coil data
Cover protection
IP40
DC
DC
DC
x
x
x
RS50 DPST(2NO) DC coil. 50A
Part Number
RS50-3022-25-1012
RS50-3022-25-1024
RS50-3022-25-1110
Coil Voltage
V DC
Coil resistance
at 20 °C in Ω
12
24
110
300
1200
25000
Coil operating range
min. (at 20°C)
max. (at 55°C)
9.00
18.00
82.50
24
48
220
Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com
DATA SUBJECT TO CHANGE WITHOUT NOTICE
103