Technical Data Diagrams Safety Relay

Safety Relay
OA/OW 5669
Features
■
■
■
■
■
■
■
■
■
■
■
2 output contacts
International approvals:
TÜV, CSA, UL, cUL
Quality control check for each safety relay
Forced-guided contacts, all gold flash plated
Contact Gap > 0.5 mm throughout life of relay
Various contact materials,
mixed contact material optional
High coil voltage range
High breakdown Voltage: contact/coil > 4 KV
High Creeping Distance: contact/coil > 8 mm
Protection Rating
OA Version: IP 40, flow solder proof
OW Version: IP 67, washable
Custom design available,
-coil voltage
-coil resistance,
-contact pressure
-operate/release time
Technical Data
GERMANY
Nominal Coil Voltage.......................................................
.....................................5, 6, 12, 20, 24, 48, 60, 110, DC
Coil Power Dissipation ..........................................0.7 W
Max. Switching Voltage....................250V DC, 400V AC
Max. Switching Current .........8 A (2 x 5A simultaneous)
■
Max. Switching Power — DC..........................................
........................................200W (2 x 160W simultaneous)
■
■
Max. Switching Power — AC..........................................
...................................2000VA (2 x1250VA simultaneous)
■
Contact Switching Rate .........10 operations per second
15 ms
Relay Operate Time .......................................... 12 ms
Relay Release Time .......................................... ■
■
■
1.4
1.3
1.2
1.1
1.0
UB 0.9
UB
0.8
Limitation factor F
UB max.
without
load
UB max.
at I max.
1
0.9
0.8
0.7
0.6
0.4
0.3
0.7
0.6
20
60
40
80
Ambient temperature
100°C
Relay operation voltage vs. ambient
temperature
6
Contact Material ..................AgNi10+0.2µmAu Standard
................AgSnO2+0.2µmAu, AgNi0.15+5µmAu Optional
■
Mechanical Life .........................50x106 operation cycles
Electrical Life ...................AgSnO2 >2x105, AgNi10 >105
■
......................operation cycles @ 230V AC, 6A, cos ϕ=1
■
Ambient Temperature ...................................-20...+85°C
Cover Material..............................................Polyamide 6
■
Weight........................................................................15 g
■
Diagrams
0.5
0.2
0.2
0.4
0.6 0.8 1
Power factor (cos ϕ )
Operations =
Operations (ohmic) x limitation factor F
Limitation factor for inductive loads
CANADA
Contact Arrangements ........1NO/1NC, 2CO, 2NO, 2NC
■
More detailed data upon request
■
■
108
260
250
6
4
220
2
180
107
140
6
4
Operations
■
US
Operation Vibration .........................0.35 mm Ampl. max
........................................................@ 10...55Hz, 5g max
■
Switching voltage U [ V]
■
C
USA/CANADA
E146415
100
60
20
0
0.2 0.40.60.81
2
4 6 8 10
Switching current l [A]
Safe disconnection, no remaining arc,
max. 1 operation/sec.
Maximum switching power curve
2
106
6
4
2
105
0 0.20.40.60.81.01.21.41.61.82.0
Switching power S[kVA]
Mechanical life
Altech Corp.® • 35 Royal Road • Flemington NJ 08822-6000 • Phone (908) 806-9400 • FAX (908) 806-9490 • www.altechcorp.com
Safety Relay 5669 Data
Rated
Voltage
5V
6V
10V
12V
20V
24V
48V
60V
110V
Relay Data
Voltage
Range
4.0 -
4.8
8.0
9.6
16.0
19.2
38.4
48.0
88.0
8.0V
- 9.6V
- 16.0V
- 19.2V
- 32.0V
- 38.4V
- 76.8V
- 96.0V
- 176.0V
Coil
Resistance
36 Ω
50
150
210
580
820
3200
5200
18000
1 NO/1 NC
Type
56.O 69.0511
56.O
56.O
56.O
56.O
56.O
56.O
56.O
56.O
Ω
Ω
Ω
Ω
Ω
Ω
Ω
Ω
69.0611
69.1011
69.1211
69.2011
69.2411
69.4811
69.6011
69.1111
Ordering Information
2 CO
Type
56.O 69.0500
56.O
56.O
56.O
56.O
56.O
56.O
56.O
56.O
69.0600
69.1000
69.1200
69.2000
69.2400
69.4800
69.6000
69.1100
Protection Class, Example:
A
IP 40, Flow Solder Proof
W
IP 67, Washable
Footprints
2 NO
Type
56.O 69.0520
56.O
56.O
56.O
56.O
56.O
56.O
56.O
56.O
69.0620
69.1020
69.1220
69.2020
69.2420
69.4820
69.6020
69.1120
2 NC
Type
56.O 69.0502
56.O
56.O
56.O
56.O
56.O
56.O
56.O
56.O
69.0602
69.1002
69.1202
69.2002
69.2402
69.4802
69.6002
69.1102
Contact Material, Example: C AgSnO2+.2µmAu
N AgNi10+.2µmAu
S AgNi0.15+5µmAu
2 NO
1 NO/1 NC
2 CO
2 NC
Dimensions
Note: All dimensions are shown in millimeters.
To convert to inches, divide by 25.4.
Altech Corp.® • 35 Royal Road • Flemington NJ 08822-6000 • Phone (908) 806-9400 • FAX (908) 806-9490 • www.altechcorp.com