LED Lamp Reliability Test Standard

Cree® LED Lamp Reliability Test Standard
criteria for performing LED Reliability Tests
This application note applies to the following High-brightness-LED products:
•
•
•
Oval and round LEDs
P4 LEDs
Surface-mount PLCC LEDs
For XLamp LED reliability information, refer to the XLamp LED Reliability Application Note(CLD-AP06).
Contents
1.003
e: CLD-CTAP0
Application Not
1. P2 RGB LED Lamps................................................................................................................2
2. P2 White LED Lamps..............................................................................................................3
3. P4 RGB LED Lamps................................................................................................................4
4. P4 White LED Lamps..............................................................................................................5
5. SMD CLV1A-FKB & CLM1 series LED Lamps....................................................................................6
6.SMD CLA1A,CLA1B,CLA2A and SP301 series LED Lamps..............................................................7
7. SMD CLM2(except for CLM2C series) and CLM4 series LED Lamps.......................................................8
8. SMD CLM2C-ACA/RCA LED Lamps...............................................................................................9
9.SMD CLM2C-GCA/BCA LED Lamps ..........................................................................................10
10. SMD CLM3 series LED Lamps...................................................................................................11
11.SMD CLM3 white LED Lamps................................................................................................12
12. SMD CLVBA-FKA LED Lamps..................................................................................................13
13. SMD CLMV & CLMU series LED Lamps.........................................................................................14
14.SMD CLX6 series(CLX6A/B/C/D) LED Lamps.............................................................................15
15.SMD CLV1S and CLV1L LED Lamps........................................................................................16
16. SMD CLY6 series(CLY6C/D/L, CLYBA) LED Lamps.........................................................................17
Subject to change without notice.
www.cree.com/ledlamps
1
1. P2 RGB LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
1000 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
1000 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
1000 hrs
0/50
Solder ability
JEITA ED-4701
300 303
Tsol=245(±5)°C,
3sec (using flux)
1time
(over95%)
0/50
Resistance to Soldering Heat
JEITA ED-4701
300 302
Tsol=260(±5)°C,10sec
(3mm from the base of the epoxy bulb)
1time
0/50
Life Test
-
TA=25°C
Oval: IF=35mA(G/B), IF=50mA(R/A)
Round: IF=30mA(G/B),IF=50mA(R/A)
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C RH=90%, IF=20mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C
IF=20mA
1000hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
100μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
2
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
2. P2 White LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
1000 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
1000 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
1000 hrs
0/50
Solder ability
JEITA ED-4701
300 303
Tsol=245(±5)°C,
3sec (using flux)
1time
(over95%)
0/50
Resistance to Soldering Heat
JEITA ED-4701
300 302
Tsol=260(±5)°C,10sec
(3mm from the base of the epoxy bulb)
1time
0/50
Life Test
-
TA=25°C, IF=30mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C RH=90%, IF=20mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C, IF=20mA
1000hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
100μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
3
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
3. P4 RGB LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
1000 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
1000 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
1000 hrs
0/50
Solder ability
JEITA ED-4701
300 303
Tsol=245(±5)°C,
3sec (using flux)
1time
(over95%)
0/50
Resistance to Soldering Heat
JEITA ED-4701
300 302
Tsol=260(±5)°C,10sec
(3mm from the base of the epoxy bulb)
1time
0/50
Life Test
-
TA=25°C
IF=30mA(G/B), IF=70mA(R/A)
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C RH=90%, IF=20mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C, IF=30mA
1000hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 30 mA
–
Initial Data x 1.2
IR
VR = 5 V
-
100μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
4
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
4. P4 White LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
1000 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
1000 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
1000 hrs
0/50
Solder ability
JEITA ED-4701
300 303
Tsol=245(±5)°C,
3sec (using flux)
1time
(over95%)
0/50
Resistance to Soldering Heat
JEITA ED-4701
300 302
Tsol=260(±5)°C,10sec
(3mm from the base of the epoxy bulb)
1time
0/50
Life Test
-
TA=25°C, IF=35mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C RH=90%, IF=20mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C, IF=30mA
1000hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 30 mA
–
Initial Data x 1.2
IR
VR = 5 V
-
100μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
5
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
5. SMD CLV1A-FKB & CLM1 series LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF: R=50mA, G=25mA, B=25mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF(single chip):R=30mA,G=15mA, B=15mA
IF(RGB): R=15mA, G=15mA, B=15mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF(single chip):R=30mA,G=15mA, B=15mA
IF(RGB): R=15mA, G=15mA, B=15mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF: R=50mA, G=25mA . B=25mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
6
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
6. SMD CLA1A,CLA1B,CLA2A and SP301 series LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF=35mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF=15mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF=15mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF=35mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
7
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
7. SMD CLM2(except for CLM2C series) and CLM4 series LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF: R=70mA, G=30mA, B=30mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF: R=50mA, G=15mA, B=15mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF: R=50mA, G=15mA, B=15mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF: R=70mA, G=30mA, B=30mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
8
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
8. SMD CLM2C-ACA/RCA LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF=50mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF=15mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF=15mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF=50mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
9
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
9. SMD CLM2C-GCA/BCA LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF: G=35mA, B=20mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF: G=10mA, B=10mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF: G=15mA, B=15mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF: G=35mA, B=20mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
10
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
10. SMD CLM3 series LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF: R=50mA, G=25mA, B=25mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF: R=30mA, G=15mA, B=15mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF: R=30mA, G=15mA, B=15mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF: R=50mA, G=25mA, B=25mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
11
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
11. SMD CLM3 white LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF=25mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF=15mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF=15mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF=25mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
12
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
12. SMD CLVBA-FKA LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF: R=18mA, G=16mA, B=10mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF: R=12mA, G=10mA, B=6mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF: R=12mA, G=10mA, B=6mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF: R=18mA, G=16mA, B=10mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
13
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
13. SMD CLMV & CLMU series LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF: R=12mA, G=6mA, B=3mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF: R=5mA, G=3mA, B=3mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF: R=5mA, G=3mA, B=3mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF: R=12mA, G=6mA, B=3mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
14
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
14. SMD CLX6 series(CLX6A/B/C/D) LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Water Proof Test#
IEC 60529:2011
IPX8 Immersing in 1m water
24 hrs
0/50
Life Test
-
TA=25°C
IF: R=30mA, G=35mA, B=20mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF=15mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF=15mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF: R=30mA, G=35mA, B=20mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Water proof test: The test is conducted on component level. It is strongly recommended customer test the product
for their application
#
Judging Criteria
Item
Symbol
Test Condition
Criteria for Judgment
Min.
Max.
Forward Voltage
VF
IF = 20 mA
–
Initial Data x 1.1
Reverse Current
IR
VR = 5 V
-
10μA
Luminous Flux/Intensity
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
15
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
15. SMD CLV1S and CLV1L LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Life Test
-
TA=25°C
IF: R=25mA, G=20mA, B=20mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF: R=10mA, G=8mA, B=8mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF: R=10mA, G=8mA, B=8mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF: R=25mA, G=20mA, B=20mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Judging Criteria
Item
Symbol
Test Condition
Forward Voltage
VF
Reverse Current
Luminous Flux/Intensity
Criteria for Judgment
Min.
Max.
IF = 20 mA
–
Initial Data x 1.1
IR
VR = 5 V
-
10μA
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
16
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps
16. SMD CLY6 series(CLY6C/D/L, CLYBA) LED Lamps
Test Items and Results
Test Item
REF.Standard
Test Condition
Note
Number of
Damaged
Temperature Cycle
JEITA ED-4701
100 105
-40°C~25°C~100°C~25°C
30 mins, 5 mins, 30 mins, 5 mins
100 cycles
0/50
Thermal Shock
MIL-STD-202G
-40°C~100°C
30 mins, 30 mins
100 cycles
0/50
High Temperature Storage
JEITA ED-4701
200 201
TA=100°C
500 hrs
0/50
Humidity Heat Storage
JEITA ED-4701
100 103
TA=60°C
RH=90%
500 hrs
0/50
Low Temperature Storage
JEITA ED-4701
200 202
TA=-40°C
500 hrs
0/50
Water Proof Test#
IEC 60529:2011
IPX8 Immersing in 1m water
24 hrs
0/50
Life Test
-
TA=25°C
IF: R=30mA G=35mA B=20mA
1000 hrs
0/50
High Temperature Life Test
-
TA=85°C
IF: R=15mA G=15mA B=10mA
1000 hrs
0/50
High Humidity Heat Life Test
-
TA=60°C, RH=90%
IF=15mA
500 hrs
0/50
Low Temperature Life Test
-
TA=-40°C,
IF: R=30mA G=35mA B=20mA
500hrs
0/50
Operation sequence
Environmental sequence
Type
Water proof test: The test is conducted on component level. It is strongly recommended customer test the product
for their application
#
Judging Criteria
Item
Symbol
Test Condition
Criteria for Judgment
Min.
Max.
Forward Voltage
VF
IF = 20 mA
–
Initial Data x 1.1
Reverse Current
IR
VR = 5 V
-
10μA
Luminous Flux/Intensity
ФV
IF = 20 mA
Initial Data x 0.7
-
Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree,
the Cree logo and XLamp are registered trademarks of Cree, Inc.
17
CLD-CTAP01.003
Cree, Inc.
4600 Silicon Drive
Durham, NC 27703
USA Tel: +1.919.313.5300
www.cree.com/ledlamps