Cree® LED Lamp Reliability Test Standard criteria for performing LED Reliability Tests This application note applies to the following High-brightness-LED products: • • • Oval and round LEDs P4 LEDs Surface-mount PLCC LEDs For XLamp LED reliability information, refer to the XLamp LED Reliability Application Note(CLD-AP06). Contents 1.003 e: CLD-CTAP0 Application Not 1. P2 RGB LED Lamps................................................................................................................2 2. P2 White LED Lamps..............................................................................................................3 3. P4 RGB LED Lamps................................................................................................................4 4. P4 White LED Lamps..............................................................................................................5 5. SMD CLV1A-FKB & CLM1 series LED Lamps....................................................................................6 6.SMD CLA1A,CLA1B,CLA2A and SP301 series LED Lamps..............................................................7 7. SMD CLM2(except for CLM2C series) and CLM4 series LED Lamps.......................................................8 8. SMD CLM2C-ACA/RCA LED Lamps...............................................................................................9 9.SMD CLM2C-GCA/BCA LED Lamps ..........................................................................................10 10. SMD CLM3 series LED Lamps...................................................................................................11 11.SMD CLM3 white LED Lamps................................................................................................12 12. SMD CLVBA-FKA LED Lamps..................................................................................................13 13. SMD CLMV & CLMU series LED Lamps.........................................................................................14 14.SMD CLX6 series(CLX6A/B/C/D) LED Lamps.............................................................................15 15.SMD CLV1S and CLV1L LED Lamps........................................................................................16 16. SMD CLY6 series(CLY6C/D/L, CLYBA) LED Lamps.........................................................................17 Subject to change without notice. www.cree.com/ledlamps 1 1. P2 RGB LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 1000 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 1000 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 1000 hrs 0/50 Solder ability JEITA ED-4701 300 303 Tsol=245(±5)°C, 3sec (using flux) 1time (over95%) 0/50 Resistance to Soldering Heat JEITA ED-4701 300 302 Tsol=260(±5)°C,10sec (3mm from the base of the epoxy bulb) 1time 0/50 Life Test - TA=25°C Oval: IF=35mA(G/B), IF=50mA(R/A) Round: IF=30mA(G/B),IF=50mA(R/A) 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C RH=90%, IF=20mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C IF=20mA 1000hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 100μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 2 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 2. P2 White LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 1000 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 1000 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 1000 hrs 0/50 Solder ability JEITA ED-4701 300 303 Tsol=245(±5)°C, 3sec (using flux) 1time (over95%) 0/50 Resistance to Soldering Heat JEITA ED-4701 300 302 Tsol=260(±5)°C,10sec (3mm from the base of the epoxy bulb) 1time 0/50 Life Test - TA=25°C, IF=30mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C RH=90%, IF=20mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF=20mA 1000hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 100μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 3 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 3. P4 RGB LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 1000 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 1000 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 1000 hrs 0/50 Solder ability JEITA ED-4701 300 303 Tsol=245(±5)°C, 3sec (using flux) 1time (over95%) 0/50 Resistance to Soldering Heat JEITA ED-4701 300 302 Tsol=260(±5)°C,10sec (3mm from the base of the epoxy bulb) 1time 0/50 Life Test - TA=25°C IF=30mA(G/B), IF=70mA(R/A) 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C RH=90%, IF=20mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF=30mA 1000hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 30 mA – Initial Data x 1.2 IR VR = 5 V - 100μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 4 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 4. P4 White LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 1000 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 1000 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 1000 hrs 0/50 Solder ability JEITA ED-4701 300 303 Tsol=245(±5)°C, 3sec (using flux) 1time (over95%) 0/50 Resistance to Soldering Heat JEITA ED-4701 300 302 Tsol=260(±5)°C,10sec (3mm from the base of the epoxy bulb) 1time 0/50 Life Test - TA=25°C, IF=35mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C RH=90%, IF=20mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF=30mA 1000hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 30 mA – Initial Data x 1.2 IR VR = 5 V - 100μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 5 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 5. SMD CLV1A-FKB & CLM1 series LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF: R=50mA, G=25mA, B=25mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF(single chip):R=30mA,G=15mA, B=15mA IF(RGB): R=15mA, G=15mA, B=15mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF(single chip):R=30mA,G=15mA, B=15mA IF(RGB): R=15mA, G=15mA, B=15mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF: R=50mA, G=25mA . B=25mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 6 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 6. SMD CLA1A,CLA1B,CLA2A and SP301 series LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF=35mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF=15mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF=15mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF=35mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 7 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 7. SMD CLM2(except for CLM2C series) and CLM4 series LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF: R=70mA, G=30mA, B=30mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF: R=50mA, G=15mA, B=15mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF: R=50mA, G=15mA, B=15mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF: R=70mA, G=30mA, B=30mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 8 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 8. SMD CLM2C-ACA/RCA LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF=50mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF=15mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF=15mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF=50mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 9 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 9. SMD CLM2C-GCA/BCA LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF: G=35mA, B=20mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF: G=10mA, B=10mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF: G=15mA, B=15mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF: G=35mA, B=20mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 10 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 10. SMD CLM3 series LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF: R=50mA, G=25mA, B=25mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF: R=30mA, G=15mA, B=15mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF: R=30mA, G=15mA, B=15mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF: R=50mA, G=25mA, B=25mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 11 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 11. SMD CLM3 white LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF=25mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF=15mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF=15mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF=25mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 12 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 12. SMD CLVBA-FKA LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF: R=18mA, G=16mA, B=10mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF: R=12mA, G=10mA, B=6mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF: R=12mA, G=10mA, B=6mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF: R=18mA, G=16mA, B=10mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 13 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 13. SMD CLMV & CLMU series LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF: R=12mA, G=6mA, B=3mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF: R=5mA, G=3mA, B=3mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF: R=5mA, G=3mA, B=3mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF: R=12mA, G=6mA, B=3mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 14 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 14. SMD CLX6 series(CLX6A/B/C/D) LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Water Proof Test# IEC 60529:2011 IPX8 Immersing in 1m water 24 hrs 0/50 Life Test - TA=25°C IF: R=30mA, G=35mA, B=20mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF=15mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF=15mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF: R=30mA, G=35mA, B=20mA 500hrs 0/50 Operation sequence Environmental sequence Type Water proof test: The test is conducted on component level. It is strongly recommended customer test the product for their application # Judging Criteria Item Symbol Test Condition Criteria for Judgment Min. Max. Forward Voltage VF IF = 20 mA – Initial Data x 1.1 Reverse Current IR VR = 5 V - 10μA Luminous Flux/Intensity ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 15 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 15. SMD CLV1S and CLV1L LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Life Test - TA=25°C IF: R=25mA, G=20mA, B=20mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF: R=10mA, G=8mA, B=8mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF: R=10mA, G=8mA, B=8mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF: R=25mA, G=20mA, B=20mA 500hrs 0/50 Operation sequence Environmental sequence Type Judging Criteria Item Symbol Test Condition Forward Voltage VF Reverse Current Luminous Flux/Intensity Criteria for Judgment Min. Max. IF = 20 mA – Initial Data x 1.1 IR VR = 5 V - 10μA ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 16 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps 16. SMD CLY6 series(CLY6C/D/L, CLYBA) LED Lamps Test Items and Results Test Item REF.Standard Test Condition Note Number of Damaged Temperature Cycle JEITA ED-4701 100 105 -40°C~25°C~100°C~25°C 30 mins, 5 mins, 30 mins, 5 mins 100 cycles 0/50 Thermal Shock MIL-STD-202G -40°C~100°C 30 mins, 30 mins 100 cycles 0/50 High Temperature Storage JEITA ED-4701 200 201 TA=100°C 500 hrs 0/50 Humidity Heat Storage JEITA ED-4701 100 103 TA=60°C RH=90% 500 hrs 0/50 Low Temperature Storage JEITA ED-4701 200 202 TA=-40°C 500 hrs 0/50 Water Proof Test# IEC 60529:2011 IPX8 Immersing in 1m water 24 hrs 0/50 Life Test - TA=25°C IF: R=30mA G=35mA B=20mA 1000 hrs 0/50 High Temperature Life Test - TA=85°C IF: R=15mA G=15mA B=10mA 1000 hrs 0/50 High Humidity Heat Life Test - TA=60°C, RH=90% IF=15mA 500 hrs 0/50 Low Temperature Life Test - TA=-40°C, IF: R=30mA G=35mA B=20mA 500hrs 0/50 Operation sequence Environmental sequence Type Water proof test: The test is conducted on component level. It is strongly recommended customer test the product for their application # Judging Criteria Item Symbol Test Condition Criteria for Judgment Min. Max. Forward Voltage VF IF = 20 mA – Initial Data x 1.1 Reverse Current IR VR = 5 V - 10μA Luminous Flux/Intensity ФV IF = 20 mA Initial Data x 0.7 - Copyright © 2007-2015 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree, the Cree logo and XLamp are registered trademarks of Cree, Inc. 17 CLD-CTAP01.003 Cree, Inc. 4600 Silicon Drive Durham, NC 27703 USA Tel: +1.919.313.5300 www.cree.com/ledlamps