Rail Mount InstallationDIN Sheet AC/DC Output Single Channel & AC Output Dual Channel SSR PART NUMBER NOMENCLATURE Single Channel (A) Operating Voltage 06: 1-60 VDC 10: 1-100 VDC 24: 24-280 VAC 48: 48-600 VAC INSTALLATION INSTRUCTIONS Series DR 06 D SOLID LAY Dual Channel Series DRD Operating Voltage 24: 24-280 VAC 48: 48-600 VAC 24 Do not forget to visit us at: www.crydom.com D 06 Switching Type Blank: Zero Voltage Turn-On (AC Output Only) R: Instantaneous Turn-On (AC Output, D suffix Only) R Agency Approvals (F) X: ATEX II 3G Ex nA IIC T4 Gc approved Rated Load Current 06: 6 Amps Control Voltage D: 4-32 VDC General Notes (A) Not all combinations of ratings are available. (B) No grounding wire required. DC inductive loads must be diode suppressed. (C) 4 Pin connector for dual channel output only. Mating connector: MOLEX 050579404 or equivalent. (D) 4 Terminal screws Pozidrive #1, 3/16 in (4.8 mm). (E) Minimum wire insulation strip length 0.20 in (5.1 mm), maximum 0.28 in (7.1 mm). X 12 Control Voltage D: 4-32 VDC A: 200-265 VAC AC Output B: 90-140 VAC Only E: 18-36 VAC STAT E RE Please read all installation instructions before using SeriesOne DR SSRs. Install the relay on the DIN rail (as shown in drawing). To install on DIN rail Wire the relay to the input side. AWG #22 minimum, AWG #16 maximum (0.3-1.3 mm2). Temperature rating of 111ºC. Wire the relay to the output side. AWG #22 minimum (0.3 mm2), AWG #14 (2.1 mm2) x 2 or AWG #12 To remove (3.3 mm2) x 1 (standed/solid) maximum. Temperature from DIN rail rating of 111ºC. Maximum recommended terminal screw torque input 4.4 in-lbs (0.5 Nm) & output 7 in-lbs (0.8 Nm). If multiple units are installed be sure to follow derating curves (reverse side of this sheet). Rated Load Current 03: 3 Amps 06: 6 Amps 12: 12 Amps X Switching Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On R Agency Approvals (F) X: ATEX II 3G Ex nA IIC T4 Gc approved Required for valid part number For options only and not required for valid part number Copyright © 2015 Custom Sensors & Technologies. Specifications subject to change without notice. Rev: 041515 Rail Mount InstallationDIN Sheet WIRING DIAGRAMS (B) DERATING CURVES Derating curves are not for the ATEX certificate evaluation AC SUPPLY 1/A 1 AC/DC CONTROL VOLTAGE DRxxx03 3.0 +3/A 1 1/A1 +3/A1 Load Current (Amp) dA Loa Load Current (Amp) For DRDxxD06 versions For DRxxx03, DRxxx06 or DRxxx12 versions 2.0 1.0 2/A 4/A 2 0.0 2 3/B1 AC SUPPLY 4/B2 2/T1 1/L1 L +A -A +B -B dB Loa (F) THIS EQUIPMENT IS OPEN-TYPE DEVICE AND IS MEANT TO BE INSTALLED IN AN ENCLOSURE SUITABLE FOR THE ENVIRONMENT SUCH THAT THE EQUIPMENT IS ONLY ACCESSIBLE WITH THE USE OF A TOOL. SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, OR NON-HAZARDOUS LOCATIONS ONLY. WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS. WARNING - EXPLOSION HAZARD - SUBSTITUTION OF ANY COMPONENT MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2. Load Current (Combined for Dual) [Amp] INPUT INPUT STATUS STATUS INPUT STATUS AC/DC SUPPLY oad DC (C) CONTROL 10 20 30 40 50 60 70 80 Ambient Temperature (°C) 2/A2 4/A2 (D, E) 5.0 4.0 3.0 2.0 1.0 0.0 0 (D, E) DRxxx06 6.0 0 10 20 30 40 50 60 70 80 Ambient Temperature (°C) DRxxx12 & DRDxxD06 12.0 Single and multiple units for DRxx03 Installed single unit, distance to adjacent components ≥ 11 mm for DRxxx06 and ≥ 18 mm for DRxxx12 & DRDxxD06 10.0 8.0 6.0 4.0 Multiple units, no minimum spacing between components 2.0 0.0 0 10 20 30 40 50 60 70 80 Ambient Temperature [°C] WARNING RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE • The product's side panels may be hot, allow the product to cool before touching. • Follow proper mounting instructions including torque values. • Do not allow liquids or foreign objects to enter this product. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH • Turn off power supply before working on this equipment. Failure to follow these instructions can result in serious injury, or equipment damage. Failure to follow these instructions will result in death or serious injury. 2320 Paseo de las Americas, Suite 201. San Diego, CA 92154 USA Tech Support Americas +1 (877) 502 5500 EMEA +44 (0) 1202 606030 Rev: 041515 Asia +86 (21) 8125 7177