PART NUMBER NOMENCLATURE Single Channel (A) AC/DC Output Single Channel & AC Output Dual Channel SSR Max Output Voltage 06: 1 to 60 VDC 10: 1 to 100 VDC 24: 24 to 280 VAC 48: 48 to 600 VAC Series Crydom SeriesOne DR Solid State Relays were developed to offer the advantages of Crydom's thermal management technology in a compact 11 & 18 mm wide IP20 housing with unique integrated heat sink. The SeriesOne DR provides a quick and easy installation onto any standard 35 mm DIN rail profile paired with high output power ratings. DR 24 D FEATURES Series AC Output Only Max Output Voltage 24: 24 to 280 VAC 48: 48 to 600 VAC Option Blank: Zero Voltage Turn-On R: Random Turn-On (AC Output Only) 24 D Output Current 06: 6 Amps 06 Control Voltage D: 4 to 32 VDC SOLID LAY STAT E RE DRxx xxx L If multiple units are installed be sure to follow derating curves (reverse side of this sheet). DRD To install on DIN rail To remove from DIN rail R Dual Channel INSTALLATION INSTRUCTIONS Install the relay on the DIN rail (as shown in drawing). Wire the relay to the input side. AWG #22 minimum, AWG #16 maximum (0.3-1.3 mm2) Wire the relay to the output side. AWG #22 minimum (0.3 mm2), AWG #14 (2.1 mm2) x 2 or AWG #12 (3.3 mm2) x 1 (standed/solid) maximum. Maximum recommended terminal screw torque input 4.4 in-lbs (0.5 Nm) & output 7 in-lbs (0.8 Nm). 12 Control Voltage D: 4 to 32 VDC A: 200 to 265 VAC B: 90 to 140 VAC E: 18 to 36 VAC Single channel 3, 6 & 12 Amps output power rating Two independent 6 Amp channels in dual channel versions Single channel 60 & 100 VDC, 24 to 600 VAC operating voltage ratings Dual channel 48 to 600 VAC operating voltage ratings 4-32 VDC, 24, 120 & 230 VAC control input options available for single channel versions 4-32 VDC control input for dual channel versions AC Output versions with Zero Voltage Turn-On for resistive loads and Random Turn-On for inductive loads LED indicates only Input status. Does not represent Output status. Please read all installation instructions before using SeriesOne DR SSRs. Output Current 03: 3 Amps 06: 6 Amps 12: 12 Amps Required for valid part number For options only and not required for valid part number (A) Not all combinations of ratings are available. R Option Blank: Zero Voltage Turn-On R: Random Turn-On (AC Output Only) Rev: 031113 DERATING CURVES WIRING DIAGRAMS (B) DRxxx06 AC/DC CONTROL VOLTAGE 2.0 1.0 4/A 30 40 50 60 70 80 2 20 2 10 0 10 20 30 40 50 60 70 80 4/A2 Ambient Temperature (°C) 2/A2 Ambient Temperature (°C) Multiple units, no minimum spacing between components 2.0 0.0 20 30 40 50 60 70 AC/DC SUPPLY d Loa +A -A +B -B AC SUPPLY 3/B1 4.0 2/T1 6.0 DC (C) CONTROL 4/B2 Single and multiple units for DRxx03 Installed single unit, distance to adjacent components ≥ 11 mm for DRxxx06 and ≥ 18 mm for DRxxx12 & DRDxxD06 8.0 1/L1 Load Current (Combined for Dual) [Amp] INPUT STATUS 12.0 10.0 10 INPUT INPUT STATUS STATUS (D, E) (D, E) DRxxx12 & DRDxxD06 0 2/A 0.0 0 AC SUPPLY 1 Load Current (Amp) 3.0 1/A1 0.0 dA Loa 4.0 +3/A 1.0 5.0 1 2.0 For DRDxxD06 versions For DRxxx03, DRxxx06 or DRxxx12 versions 6.0 1/A 3.0 +3/A1 Load Current (Amp) DRxxx03 dB Loa 80 Ambient Temperature [°C] WARNING DANGER (B) No grounding wire required. DC inductive loads must be diode suppressed. (C) 4 Pin connector for dual channel output only. Mating connector: MOLEX RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE • The product's side panels may be hot, allow the product to cool before touching. • Follow proper mounting instructions including torque values. • Do not allow liquids or foreign objects to enter this product. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH 050579404 or equivalent. • Turn off power supply before working on this equipment. (D) 4 Terminal screws Pozidrive #1, 3/16 in (4.8 mm). (E) Minimum wire insulation strip length 0.20 in (5.1 mm), maximum 0.28 in (7.1 mm). Failure to follow these instructions can result in serious injury, or equipment damage. Failure to follow these instructions will result in death or serious injury. Rev: 031113