Level Switch LFFS Special Features Wetted parts in acid-proof, stainless steel and PEEK Compact, food compatible, hygienic design Hygienic connections conform to 3-A standards, FDA demands and EHEDG guidelines Precise switching point without calibration Process temperature -40...200 °C Measures media with DK-values >1.5 (DK = Dielectrical Constant) Not influenced by foam LED switch indicator Maintenance free Suitable for media separation measurement Configurable by FlexProgrammer 9701 ATEX approval for gas and dust WHG approval (leakage and overfill) Technical Data Sensor Approvals/conformities Hygienic: G1/2, 3-A/DN38 or sliding connection Adapters Refer to page 5 Insulating material PEEK Natura Mechanical data Housing Stainless Steel, W1.4301/AISI 304 Process connection Stainless Steel, W1.4404/AISI 316 L Amb. temperature -40...85 °C Process temperature Std. & 3-A/DN38 Sliding connection < 1 hour, Tamb < 60 °C Protection class -40...115 °C (See curve 1) -40...200 °C (See curve 1) -40...140 °C IP67 (IEC 529) Media pressure Standard G½ hygienic < 100 bar (tested with water at 20°C) 3-A DN38 < 40 bar Sliding connection < 16 bar Vibrations IEC 60068-2-6, GL test2 Installation Any position Electrical connection Cable gland M16 Plast or Nickel-plated brass Plug M12 Nickel plated brass or stainless steel AISI 304 Other electrical data Power supply 12,5...36 VDC, 35 mA max. Damping 0...10 sec. Power-up time Approvals/conformities EN 1935/2004, EN 10/2011, EN 2023/2006, EN 50155 Railway, 3-A, EHEDG, FDA, WHG (leakage and overfill) UL listed, E36692 Disposal of product and packing According to national laws or by returning to Baumer. EMC data Immunity EN 61326 Emission EN 61326 Ex data (ia) Internal inductivity Li < – 10 μH Internal capacity Ci < – 33 nF Barrier data U< – 30 VDC ; I < – 0.1 A ; P < – 0.75 W Approval Ex ia IIC T5, ATEX II 1G (See table 1) Supply range 24...30 VDC Temperature class T1...T5: -40 < Tamb < 85 °C Approval Ex tD A20 IP67 T100 °C, ATEX II 1D (See table 1) Supply range 12,5...30 VDC Temperature class T100 °C: -40 < Tamb < 85 °C Approval Ex nA II T5, ATEX II 3G (See table 1) Supply range 12,5...30 VDC Temperature class T1...T5: -40 < Tamb < 85 °C Output Output (active) Max. 50 mA, short-circuit and high-temperature protected <2 sec. Output type PNP, NPN or Digital output (Push-pull) Hysteresis ± 1 mm Output polarity See drawing Repeatability ± 1 mm Active “Low” Reaction time 0.1 sec. (100 mS) NPN and Digital output (-VDC +2.5V) ± 0.5V ; Rload 1 kOhm Active “High” PNP and Digital output (VDC -2.5V) ± 0.5V ; Rload 1 kOhm Off leak current ± 100 μA Max. www.baumer.com Data sheet E21.04 LFFS-1_EN Page 1 / 8 Design and specifications subject to change without notice 100...180 MHZ Process connection EN/2014-08-26 Radiated signal Level Switch LFFS Technical Data Factory Settings Output PNP, NPN or Digital Measure DK value >1,5 Damping 0.1 sec. Dimensional Drawings [mm] ø55 58 Safety chain G1/2 Hygienic sliding nipple M16 gland M12 plug AF22 G1/2 44 19 Sliding connection length, refer to ordering data Washer ring kit, 2 items Type no. 4401 8001 included 31.5 G1/2 Hygienic, Sliding connection 3A/DN38 Hygienic connection O-ring EPDM incl. 18 G1/2 Hygienic connection EN/2014-08-26 Design and specifications subject to change without notice Sliding connection load www.baumer.com Data sheet E21.04 LFFS-1_EN Page 2 / 8 Level Switch LFFS Electrical Connection Output Teach-in 4 5 Sensor M12 plug: Case 6 3 4 3 1 2 1 : Brown 2 : White 3 : Blue 4 : Black 1 2 + or (-) - or (+) 12,5...36 Vdc M12plug Electrical Installation Normally Open PLC 0 mA Active High 50 mA LED + + - 12.5 ... 36 VDC 12.5 ... 36 VDC - - NPN Output 50 mA max. PNP Output 50 mA max. + 12,5...36 VDC Digital Output 50 mA max. Normally Closed PLC 50 mA LED - + 12,5...36 VDC - PNP Output 50 mA max. Active Low + 12,5...36 VDC 12,5...36 VDC Digital Output 50 mA max. NPN Output 50 mA max. Configuration Accessories Design and specifications subject to change without notice 0 mA + FlexProgrammer 9701 Red clip Red clip 1 2 2 Black clip Black clip Note: Ambient temperature range 0...50°C Note: Ambient temperature range 0...50°C Disconnect the power 1 1 1 1 2 2 2 2 www.baumer.com Disconnect the power supply before connecting supply before connecting the FlexProgrammer 9701 the FlexProgrammer 9701 to the Level Switch LFFS to the Level Switch LFFS The FlexProgrammer 9701 is a dedicated tool to configure all Baumer configurable Flex-products. Type No. 9701-0001 comprises: FlexProgrammer Cables CD with the FlexProgram software EN/2014-08-26 1 Data sheet E21.04 LFFS-1_EN Page 3 / 8 Level Switch LFFS The Sliding Connection (Figure 1) External length of sliding connection 1) Free external length of sliding connection see curve 1 below 1) Insulation 2) Insulation 2) 4) Lumpy or sticky media 4) Lumpy or sticky media 3) The drawing shows how the sliding connection can be used for at least 4 applications: 1) Mounted at the top of a tank to adjust to a maximum level. 2) Serving as a cooling neck in high media temperature applications. 3) Adjusted to place the sensor tip deeper inside the tank. 4) To reach in through insulation material. It is essential that the max. ambience temperature for the electronics is never exceeded. For ATEX approved products please refer to table 1. 3) Curve 1: Example, how to read A 250 mm sliding connection is mounted in a tank with a total insert length of 150 mm. Hence the external length of the sliding connection will be 250 - 150 = 100 mm. The media temperature will be max. 160 °C. Read the x-axis at 100 mm an the y-axis at 160 °C and find that the ambient temperature must be kept below 50 °C. In case the radiated heat from the tank will cause a higher ambient temperature at the housing efficient insulation of the tank must be established The working conditions for the sliding connection in different media temperatures and specified ambient temperatures can be found in curve 1. Media Temperature versus External Length of Sliding Connection (Curve 1) Media Temperature Kølehals for FLS °C Mikael Jensen / 2009-08-26 210 200 190 Tamb max. 40°C 180 Tamb max. 60°C 170 Design and specifications subject to change without notice Tamb max. 75°C 160 150 140 130 120 110 100 Tamb max. 85°C 90 80 70 60 50 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 www.baumer.com Data sheet E21.04 LFFS-1_EN EN/2014-08-26 External length of sliding connection (mm) See figure 1 NB: Std. + 3A/DN38 = 35 mm external length Page 4 / 8 Level Switch LFFS Accessories - Overview R R 74 - 03 74 - 03 LFFS-xx1 LFFS-xx2 LFFS-xx3/4 R 74 - 03 R R 74 - 03 74 - 03 CAM 023 MAM02x-xxx PM023 Welding part 3A/DN38 hygienic 81 26-916 LAM020-1 PM021 VAM 023 R 74 - 03 SAM020-051-1 PM022-x Welding part 3A/DN38 hygienic 81 26-928 Design and specifications subject to change without notice Please refer to the data sheet “FlexBar Accessories” for these accessories. RAM020-1 PM025 RAM020-2 EN/2014-08-26 Please refer to the data sheet “Accessories Universal” for these accessories. www.baumer.com Data sheet E21.04 LFFS-1_EN Page 5 / 8 Level Switch LFFS Ex ia G - Installation Conditions for Ex-Certification (Table 1) A Level Switch LFFS-1xx is Ex ia IIC T5, ATEX II 1G approved for application in hasardous areas in accordance with the current EUdirectives. The product must be installed in accordance with prevailing guidelines for zone 0 with a barrier. Ex tD - Installation Connection Type Tamb °C Std. & 3-A/DN38 Sliding 100 mm A Level Switch LFFS-2xx is Ex tD A20 IP67 T100°C, ATEX II 1D approved for application in hasardous areas in accordance with the current EU-directives. The product must be installed in accordance with prevailing guidelines for zone 20 without a barrier. Sliding 250 mm Ex ia G, Ex nA G - Installation A Level Switch LFFS-3xx is Ex nA II T5, ATEX II 3G approved for application in hasardous areas in accordance with the current EUdirectives. The product must be installed in accordance with prevailing guidelines for zone 2 without a barrier. Media Temp. max. °C Note -40...85 85 -40...60 95 {2} -40...40 115 {2} -40...85 85 -40...60 150 {2} -40...40 175 {2} -40...85 85 -40...60 195 {2} -40...40 200 {2} {3} Note {2}: Provided that the sensor tip at the instrument is the only part in contact with the media. Note {3}: Max. allowed media temperature. Ex ia IIC T5, ATEX II 1G - Installation Ex-data Supply range 24...30 VDC Temperature class T1...T5: See table 1 Internal inductivity Li < 10 μH Internal capacity Ci < 33 nF Barrier data U < 30 VDC ; I < 0.1 A ; P < 0.75 W Safe area Zone 0/1 PNP out 3 2 1 NO NC COM + C 22...120VDC or 90...253 VAC Design and specifications subject to change without notice A Level Switch LFFS-1xx is Ex ia IIC T5, ATEX II 1G approved for application in hasardous areas in accordance with the current EUdirectives. The product must be installed in accordance with prevailing guidelines for zone 0 with a barrier. A certified Ex ia or isolation barrier with the maximum values Umax = 30 VDC ; Imax = 0.1 A ; Pmax = 0.75 W must be used. - B A Level Switch LFFS Isolating Module PROFSI3-B25100-ALG-LS EN/2014-08-26 Only valid forthe PNP output NB: For NB: PNP output PROFSI3-B25100-ALG-LS barrier must be used. Isolating Module PROFSI3-B25100-ALG-LS www.baumer.com Data sheet E21.04 LFFS-1_EN Page 6 / 8 Level Switch LFFS Ex tD A20 IP67 T100, ATEX II 1D - Installation A Level Switch LFFS-2xx is Ex tD A20 IP67 T100°C, ATEX II 1D approved for application in hasardous areas in accordance with the current EU-directives. The product must be installed in accordance with prevailing guidelines for zone 20 without a barrier. Ex-data Supply range 12,5...30 VDC, max 100 mA Temperature class T100: See table 1 Out + 12,5...30 VDC External lamp Level Switch LFFS Ex nA II T5, ATEX II 3G - Installation A Level Switch LFFS-3xx is Ex nA II T5, ATEX II 3G approved for application in hasardous areas in accordance with the current EUdirectives. The product must be installed in accordance with prevailing guidelines for zone 2 without a barrier. Ex-data Supply range 12,5...30 VDC, Max. 0.1A Temperature class T1...T5: See table 1 Remote Lamp 3 1 Design and specifications subject to change without notice 2 12,5..30 VDC EN/2014-08-26 Level Switch LFFS www.baumer.com Data sheet E21.04 LFFS-1_EN Page 7 / 8 Level Switch LFFS Ordering details – Model Level Switch 5' digit Safety Standard Ex ia IIC T5, ATEX II 1G (Gas) * Ex tD A20 IP67 T100 °C, ATEX II 1D (Dust) Ex nA II T5, ATEX II 3G UL listed, E365692 6' digit Electrical Connection Plug, M12, Nickel plated brass Cable gland, M16 brass Cable gland, M16 Polyamid Plug, M12, stainless 7' digit Process Connection G1/2, PEEK tip (1) 3-A/DN38 Hygienic connection (1) G1/2, PEEK tip, sliding connection, 100 mm adjustable, incl. washer ring kit 4401 8001 (2) G1/2, PEEK tip, sliding connection, 250 mm adjustable, incl. washer ring kit 4401 8001 (2) 8' digit Configuration No configuration Configuring according to customer specification * For PNP output the barrier module PFOFSI3-B25100-ALG-LS is required for funtional purposes. LFFS 0 1 2 3 A 1 2 3 4 1 2 3 4 0 C The washer ring kit for sliding connection, type no. 4401 8001 Can be ordered separately. Baumer recommended to replace this kit if deformed. 3-A certificate / EHEDG certificate The 3-A mark and the EHEDG certifcate is valid only when the product is mounted in a 3-A marked or EHEDG certified counter part and installed according to the installation manual. Use also a 3-A marked O-ring or gasket if relevant. The 3-A marked products conforms to the 3-A Sanitary Standard criteria. Materials and surfaces fulfill the FDA demands and are certified by EHEDG. (1) Certified by EHEDG. Fulfills the FDA demand. EPDM O-rings supplied with 3-A marked products are conform to Sanitary Standard Class II (8% milk fat max.) EPDM gaskets supplied with 3-A marked products are conform to Sanitary Standard Class I (8% milk fat max.) Refer to the 3-A marked counter parts in the data sheet “Accessories Universal”. Level Switch LFFS, example (2) Design and specifications subject to change without notice PEEK Natura EN/2014-08-26 Angle > 135 deg. www.baumer.com Data sheet E21.04 LFFS-1_EN Page 8 / 8