CombiView DFON Graphical display Main features Graphical display with Option: Two configurable relay backlight Showing errors and limits by steady or flashing colours Fits Baumer CombiSeriesTM (Ø80 mm FlexHousing) Hygienic design outputs Programmable by touch screen Easy and fully programmable with FlexProgrammer 9701 ATEX Applications Remote display fits for all 4 - 20 mA transmitter Wall mounting, panel mounting and pipe mounting Technical Data Relay Connections 3.5…23 mA (normal working range 4...20 mA) 2 screw terminals for loop power, signal 4 screw terminals for relay outputs Accuracy ≤ ±0.1% of input span within -10...70 °C ≤ ±0.2% of input span within -30...-10 °C / 70...80 °C Loop voltage drop Sample time Two levels depending on chosen backlight brightness @ 20 mA : - Low bright backlight (<40%) : Max. 4V @23 °C - High bright backlight (>40%) : Max. 6.5V @23 °C ≤ 1 second. Typical 0.3 second Start-up time ≤ 5 second User-configurable data Measuring range 4...20 mA Error/warning indication Individually configurable display and backlight indication in white, green or red colour, steady or flashing light. Configurable limits between 3.5 and 23 mA Zoom on range Minimum 2 mA of input span Damping 0...30 seconds Linearization table 2 to 30 points Measuring unit (standard selectable) °C, °F, K bar, mbar, kPa, MPa, psi, kg/cm2, mmHg, mH2O, atm, "Hg, mHg, "H2O, %, l/h, Ton, m3, m3/h, Hz, mS, mV, V, ohm, Hz, sec, %, mA, or user defined (programmable with FlexProgrammer) 8 x 20 pixels matrix User defined unit Dec. point position www.baumer.com Contacts 2 solid state relays Voltage 60 Vp Load Current 75 mA Max On resistance 10 Ohm The built in relays are not activated as standard. They can be activated at purchase or SW activation code can be purchased later. Display Type FSTN Graphically LCD Measuring range -9999...99999 Digit height Max. 22 mm EMC data Immunity EN 61326 Emission EN 61326 EMC immunity Influence ≤ ±1% of input FS Communication FlexProgrammer 2-way communication for configuration. Test conditions Operating temperature 23°C ± 2 °C xxxxx, xxxx.x, xxx.xx, xx.xxx, x.xxxx, .xxxxx, AUTO EN/215-01-30 Measuring range Design and specifications subject to change without notice Input Data sheet D21.09 Page 1 / 5 CombiView DFON Graphical display Technical Data Environmental conditions ATEX Gas ia and for ATEX Dust ia Operating temperature -30...80 °C Approval Gas Zone 0/1 Dust Zone 20/21 Storage temperature -40...85 °C Voltage drop UDisp Humidity max. 98% RH, condensing Temperature class Vibrations IEC60068-2-6, test FC 25...100 Hz, 4.0g DNV high vibration strain, class B 1.6mm, 2...25 Hz T1...T5 Zone 0 and 20 -20 ... 60 °C Zone 1/2 and 21/22 -30 ... 65 °C Internal inductivity L i <10 µH Internal capacity C i <15 nF Barrier data U i Ii Pi <30 VDC <0.1 A <0.75 W Optimal readability Mechanical tolerances -10...70 °C ISO 2768-m Mechanical data II 1 G, Ex ia IIC T5 Ga II 1 D, Ex ia IIIC T100°C Da 4.5 ... 6.5 VDC ATEX Gas nA Dimensions See dimensional drawing Approval Gas Zone 2 Material Polycarbonate plastic Voltage drop UDisp Enclosure ø 80 mm housing and front ring stainless steel, AISI 304 Temperature class T1...T5 -30 < Tamb< 65 °C Protection class IP 10 on terminals IP 67 in ø 80 mm housing Internal inductivity L i <10 µH Internal capacity C i <15 nF Weight 100 g - display alone 170 g - display incl. front ring 475 g - display in ø 80 mm housing for wall mounting Maximum voltage Umax <35 VDC Maximum current Imax <0.1 A II 3 G, Ex nA II T5 4.5 ... 6.5 VDC Electrical connections Terminal 1 - Supply + Terminal 2 - Supply – Other data Temperature drift Power up time ≤ 0,001%/10K (inside optimal readability temperature range) ≤ 0,0015%/10K (outside optimal readability temperature range) Terminal 3 - Relay 2 Terminal 4 - Relay 2 Terminal 5 - Relay 1 Terminal 6 - Relay 1 ≤ 15 sec. Disposal of product and packing According to national laws or by returning to Baumer. Programming The FlexProgrammer 9701 is a dedicated tool to Configure all Baumer configurable products. FlexProgrammer, No. : 9701.0001 It is not necessary to disconnect the power to the CombiView, DFON display The FlexProgrammer interface unit will be delivered complete including - CD with FlexProgram software - Product drivers (DTM-files) - cables EN/215-01-30 The CombiView, DFON can also be programmed by the touch bottoms on the display. Please see "Operating instructions for CombiView, DFON". Design and specifications subject to change without notice Connect the FlexProgrammer to the CombiView, DFON as per below. www.baumer.com Data sheet D21.09 Page 2 / 5 CombiView DFON Graphical display Electrical connections ATEX Gas ia and for ATEX Dust ia Display in the zone, transmitter outside the zone Display and transmitter in the zone 4 ... 20 mA 4 ... 20 mA 1+ CombiWiev, DFON 2- Zener barrier 1+ 15 ... 30 VDC 15 ... 30 VDC 2- Display in the zone/transmitter outside the zone Display and transmitter in the zone 4 ... 20 mA 4 ... 20 mA 1+ 1+ 2- Zener barrier 15 ... 30 VDC Zener barrier 0 ... 30 VDC 75 mA 4 5 Relay 2 Zener barrier 0 ... 30 VDC 75 mA 6 Zener barrier 15 ... 30 VDC Relay 1 Zener barrier 0 ... 30 VDC 75 mA Relay 2 Zener barrier 0 ... 30 VDC 75 mA 23 3 Relay 1 CombiWiev, DFON Zener barrier CombiWiev, DFON CombiWiev, DFON 4 5 6 ATEX Gas nA Display without relay output Display with relay output 1+ 1+ 4 ... 20 mA 2- 4 ... 20 mA 3 CombiWiev, DFON CombiWiev, DFON 2- Relay 1 4 5 Relay 2 6 Value Small / Large Analog w. Bar graph / Value Bar graph Vertical / horizontal Tank illustration Tank / Bottle Status ok www.baumer.com EN/215-01-30 Visual alert Design and specifications subject to change without notice Selectable views Alert status Data sheet D21.09 Page 3 / 5 CombiView DFON Graphical display Drawings / Dimensions in mm Ø 81 23 Mounting for stand alone instrument Wall mounting, DFON-xxx.2.2x FlexHousing with Ø110 mm rear flange with 3 x Ø4 mm holes for screws 59 PCO Ø 95 Ø 91 Ø 110 10 Panel mounting, DFON-xxx.2.30 Ø110 mm front flange with 3 x Ø4 mm holes for screws 29 EN/215-01-30 DN38 DN51 DN64 Design and specifications subject to change without notice Ø 110 FlexHousing with pipe bracket for Ø38, Ø51, Ø64 mm stand pipe 70 Ø 91 Pipe mounting, DFON-xxx.2.4x / ...2.5x / ...2.6x Ø 79 Ø 91 10 www.baumer.com Data sheet D21.09 Page 4 / 5 CombiView DFON Graphical display Ordering details Model CombiView Safety Standard EX II 3G, Ex nA II T5 EX II 1 G Ex ia IIC T5 Ga or EX II 1D Ex ia IIIC T100°C Da Relays Not activated Activated Configuration None Configured according to customer specification Front ring None Front ring for Ø80 mm SS housing (FlexBar + CombiTemp 814) Front ring for SS FlexHousing (CombiSeries) DFON . – DFON 1 3 5 1 2 0 1 0 1 2 . Housing None FlexHousing wall mounting FlexHousing panel mounting FlexHousing tube mounting DN38 FlexHousing tube mounting DN51 FlexHousing tube mounting DN64 Electrical connection on housing None 1 x M16 plastic cable gland 2 x M16 plastic cable gland 1 x M16 stainless steel cable gland 2 x M16 stainless steel cable gland 1 x M20 plastic cable gland 2 x M20 plastic cable gland 1 x M20 stainless steel cable gland 2 x M20 stainless steel cable gland 0 2 3 4 5 6 0 3 4 5 6 7 8 9 A Accessories, Software for relays Activation code for relays (for instruments with not activated relays) UnitCom ribbon cable (for retrofitting of DFON on TFRx and PFRx) EN/215-01-30 Design and specifications subject to change without notice DFO-SW 11128715 www.baumer.com Data sheet D21.09 Page 5 / 5