YTED/YTTN ATEX Ex ia System

PRESSURE SWITCHES
YTED/YTTN
ATEX Ex ia System
Main characteristics
Safety module ATEX for hazardous areas
Intrinsic Safety
LCIE 03 ATEX 6078X
I/II (M1) (1)G/D [Ex ia] I/IIC – [Ex iaD]
Applications
Process technic
Hydraulic
Pneumatic
Refrigeration
Water treatment
Car industry
Test benches
Safety
Aerospace
Railways
Shipbuilding
Heavy vehicule
Health care
Biotechnology
Food
Beverage
Pharmaceutical
Petro-chemical
Chemical
HVAC
Energy
Medical gas
Agriculture vehicules
Pumps and compressors
Module with 2 threshold outputs, active or passive 4 ... 20 mA output, power supply PROFSI3
The PROFSI3-B25091-ALG-YT module, with intrinsic safety analogue interface makes it possible to connect a series YT
thermostat or pressure switch in input, while ensuring safety between the danger zone (at risk of explosion) and the safe
area through galvanic isolation.
The module provides excitation for the YT pressure switch/thermostat; the galvanically isolated input signal recopy is active
or passive depending on the connection chosen. The 2 thresholds defined on the YT pressure switch/thermostat are available on relays.
Banana jacks on front panel can be used for the 4-20 mA recopy loop test.
Power supply to the module can be AC or DC on a wide range.
Special conditions for safe use:
The PROFSI3-B25091-ALG-YT module is an apparatus complying with ATEX Directive 94/9/EC No. LCIE 03 ATEX 6078X.
General marking
I/II (M1) (1)G/D [Ex ia] I/IIC – [Ex iaD]
Ambient temperature : - 20°C ≤ Ta ≤ + 60°C
Category (M1) or (1)D or (1)G
This apparatus is an intrinsically safe associated material; it must not be installed in an explosive area. It can be connected to
equipment installed in areas 0,1, 2 - gas (G), or areas 20, 21, 22 - dust (D).
www.baumer.com/process
Design and specifications subject to change without notice
Data sheet A31.04
Page 1
Model / PROFSI3 type module
Technical data
Supply voltage
Consumption
4 ... 20 mA signal recopy
Relay outputs
Threshold states
DC from 22VDC to 120VDC
50 or 60Hz AC from 90 to 253VAC
Power supply
3 VA
Max. ambient temperature
Optoelectronically isolated
Accuracy of the isolated recopy 0.1% Recommended ambient T°
Maximum load 600 Ω
Storage temperature
Transfer time < 5ms
Dimensions
Thermal drift zero: 50ppm/°C
Thermal drift gain: 50ppm/°C
Residual ripple ± 50mV
1 work contact per threshold
1 common to the 2 thresholds
Breaking capacity for cosφ =1
- 4A at 250VAC
- 4A at 30VDC
Breaking capacity for cosφ =0.4
- 1.5A at 250VAC
- 1.5A at 30VDC
Breaking capacity max 500VAC
Contact resistance max. 100mΩ
for 100,000 operations min.
for 20,000,000 operations min.
Mounting
LED display on front panel for each
threshold
Front panel LED
- 20 ... + 60°C
- 20 ... + 50°C
- 40 ... + 80°C
Depth : 120 mm
Height : 90 mm
Width : 29 mm
Symmetric hat profile rail mounting
Connection by pull-out terminals
Module power distribution by plug-in flat cable unit
Ordering Information - PROFSI3 Module
Item number : PROFSI3-B25091-ALG-YT
Order code : 0602
www.baumer.com/process
Design and specifications subject to change without notice
Data sheet A31.04
Page 2
Installation diagram
Connections of input - CN1
Connections of input - CN2
Connection to YT... pressure switch or thermostat
Active 4 ... 20 mA recopy
Danger area
Threshold 1
Threshold 2
YT... thermostat or
pressure switch
Safe area
black
PROFSI3-...-YT
Threshold 1
white
Threshold 2
blue
7
6
5
4
3
2
1
> Threshold 1
> Common
> Threshold 2
Shield (earth)
> - active 4-20mA
> + isolated output
brown
Passive 4 ... 20 mA recopy
PROFSI3-...-YT
7
6
5
4
3
2
1
>
>
>
Threshold 1
Common
Threshold 2
Shield (earth)
> - passive 4-20mA
> + isolated output
The passive 4 ... 20 mA output may be connected to a 6-28
VDC circuit. Voltage drop at 22mA 6V.
To ensure proper operation, it is imperative to connect the
recopy to a load. If recopy is not necessary, make a short
circuit between 1 and 2.
Front access to check 4 ... 20 mA loop
A flat-cable unit is used to distribute power supply from one
PROFSI3 module to the next.
All terminals are removable.
2mm banana jacks on front panel for 4 ... 20 mA recopy loop
test without 10mV/mA opening.
CN3/4
Power supply connections - CN3/CN4
90-253VAC
L 22-120VDC
EARTH
N
Caution
All modules are equipped with 2 pull-out 3-point connectors
(L N) for power supply wiring: one for input and one output
terminal for bridging to another module using the 3-point flat
cable supplied. To prevent electric shocks, it is imperative
that these terminals are always connected. If only one of
these connectors is used (no bridging to another module),
the other one must be closed by the blind 3-point plastic cap
supplied with the product.
Mimic diagram of connections
Danger area
thermostat
or pressure
switch
YT...
Safe area
D
C
B
A
5 67
> Threshold 2
> Common
> Threshold 1
L/+
Auxiliary power
N/Passive recopy in 2/3
1 2 34
Shield (earth)
> - active 4-20mA
isolated
output
isolée
> + sortie
earth
www.baumer.com/process
Design and specifications subject to change without notice
Data sheet A31.04
Page 3
Connecting cable
The cable is suitable for use in a hazardous ATEX Ex ia area. It allows the connection from the YTED/YTTN to the PROFSI3B25091-ALG-YT module.
Characteristics
M12 5-pin removable metal connector + 4-wire shielded
cable
Code de commande
Code
0623
0624
0625
Length (m)
20
50
100
The system can be equipped with an approved junction box or in compliance with the requirements of the standards EN60079-1
and EN60079-11.
Dimensions
Order code
127 x 81 x 57 mm
0603
www.baumer.com/process
Design and specifications subject to change without notice
Data sheet A31.04
Page 4
UK/01-2011 This data sheet may only be reproduced in full
Junction box